OPERATIONS
PAGE 35
3. STATUS
(5 defined)
Run
During startup initialization or upgrading Flashing Red
During program mode (PC or handset)
Solid Red
Operating
No low power modes selected
Flashing Green
Low power mode in effect
Normal conditions
Short Green Flash
Error condition
Short Red Flash
Tone
Idle
Off
While a tone is being transmitted
Solid Red
While a tone is being received
Solid Green
Voice
Voice
Off
While speaking
Solid Red
While recording
Solid Green
Phone
This indicator is used in conjunction with the SIGNAL indicators, see below
Radio
Idle
Off
While PTT is active
Solid Green
While COS is active (busy)
Solid Red
4. SIGNAL
Refer to the Signal & Telephone Status table found on Page 32.
5. OUTPUT
(4, one for each output relay)
If the relay is in the idle state
Off
If the relay is in the ON state
Solid Red
If the relay has failed
Solid Yellow
Power Switch
This switch is located next to the DB9 connector and is used to bring the
system out of low power mode, put the system back into low power mode
and to shut the system down when it is operating from battery only.
When the Cv3 is in a low power mode, it will show only a blinking run
indicator. Pressing the power switch briefly will restore operation to full
power.
While the Cv3 is operating at full power, pressing the switch briefly will
force it into low power mode. The unit cannot be forced into low power
operation if alarm reporting activities are taking place.