background image

Duplex System

21

1

Lifting Device (Not Shown), Polypropylene Rope, Stainless Cable, Steel Chain

22

1

Mounting Bracket (Included with #29)

Stainless

094719

23

1

Cover Gasket

034452

24

2

Pipe Nipple (Not Used with 2" Piping)

1.25" NPT x Close, Stainless

075476

1.25" NPT x 1.62" lg, PVC

094914

28

1

J-Bolt

Stainless

058811

29

1

Junction Box

See Table 2

30

1

Float Pole Assy. (Includes Floats #30A)

48" Basin Depth, SGV

094162

60" Basin Depth, SGV

079124

72" Basin Depth, SGV

079126

84" Basin Depth, SGV

079128

96" Basin Depth, SGV

079130

108" Basin Depth, SGV

079132

120" Basin Depth, SGV

079134

132" Basin Depth, SGV

079136

144" Basin Depth, SGV

079138

168" Basin Depth, SGV

097326

30A

4

Floats (Specify Cord Length)

073617

32

2

Extention Handle Bracket

099196

33

2

Pipe Nipple, 36"Dia. Basins

1.25" NPT x Close, Stainless

075476

                    42", 48" & 60" Dia. Basins

1.25" NPT x 2.50" Lg, Stainless

075896

                    42", 48" & 60" Dia. Basins

1.25" NPT x 1.62" Lg, PVC

094914

                    42", 48" & 60" Dia. Basins

2" NPT x Close, Stainless

075478

                    42", 48" & 60" Dia. Basins

2" NPT x Close, PVC

093927

34

1

Serial Plate

35

4

Cap Screw

1/4-20 x .75" Lg., Stainless

1-5-1

37

24

Sealing Washer

3/8"

082727

38

1

Bug Free Vent 

2"

075831

39

1

Pipe Nipple

1.25" NPT x Close, Stainless

075476

1.25" NPT x 1.62" Lg., PVC

094914

2" NPT x Close, Stainless

075478

2" NPT x Close, PVC

093927

40

1

Vent Flange 

2"

026210A

41

6

Strain Relief Cable Grips (STD)
Electrical Coupling, 1.25" (Not Shown) OPTIONAL

078470

1

Electrical Coupling, 1.50" (Not Shown) OPTIONAL

078471

1

Electrical Coupling, 2.00" (Not Shown) OPTIONAL

078471D

42

2

Hex Hd Screw

3/8-16 x 1-1/2" Lg. Stainless

1-38-1

43

2

Lock Washer

3/8" Stainless

20-14-1

44

1

Inlet, Flexible Pipe Fitting

4" Sch. 40 PVC, Grey

076149

4" SDR 35, PVC 

(STD)

, Maroon

075898

6" Sch. 40 PVC, Black

076941

6" SDR 35, PVC, Yellow

076111

Caulking Hub

4", Cast Iron

063847

Caulking Hub 

6", Cast Iron

063848

Caulking Hub

8", Cast Iron

063850

45

1

Close Nipple

2", NPT, PVC

093927

46

8

Hex Hd Screw

5/16-18 x 1-1/4" Lg, Stainless

1-131-1

47

6

Hex Hd Screw

3/8-16 x 1" Lg, Stainless

1-529-1

48

4

Hex Hd Screw

1/4-20 x .75" Lg, Stainless

1-523-1

49

5

Lockwasher

1/4", Stainless

022333

50

7

Hex Nut

1/4-20, Stainless

15-5-1

51

2

Elbow 

90° x 1.25" NPT, Stainless

075481

90° x 1.25" NPT, PVC

094820

(Also used in PVC Piping)

Street x 2" NPT, Stainless

083933

52

1

Tee

1.25" NPT, Stainless

075493

1.25" NPT, PVC

094915

2" NPT, Stainless

075494

2" NPT, PVC

094905

53

1

Reducer

1.25" NPT x 1.50" NPT, Stainless

094916

1.25" NPT x 1.50" NPT, PVC

094918

2" NPT x 2.50" NPT, Stainless

076110

2" NPT x 2.50" NPT, PVC

094906

25

Summary of Contents for UltraGRIND

Page 1: ...Inc constant product improvement program product changes may occur As such Crane Pumps Systems Inc reserves the right to change product without prior written notification 420 Third Street P O Box 603...

Page 2: ...plex w Moist Temp 200 230V 1Ph 200 230 460V 3Ph Fig 17 14 SGV Simplex w Temp 5HP 200 230V 1Ph Fig 18 15 SGV Simplex w Moist Temp 5HP 200 230V 1Ph Fig 19 16 SGV Duplex 200 230V 1Ph 200 230 460V 3Ph Fig...

Page 3: ...es UltraGRIND grinder pump station The basin collects all wastewater from the house The solids in the sewage are then ground to a small size suitable for pumping in the slurry The grinder pump generat...

Page 4: ...rvicing 18 Only qualified personnel should install operate and repair pump 19 Keep clear of suction and discharge openings DO NOT insert fingers in pump with power connected 20 Do not pump hazardous m...

Page 5: ...the bottom of the basin and reach a compaction of 85 Standard Proctor Density See Figure 1 GRAVEL SPECIFICATION 1 A naturally rounded aggregate is required clean and free flowing with particle size n...

Page 6: ...Adapter or Caulking hub may be used in place of the flexible pipe fitting see Sections B 3 2 and B 3 3 TABLE For FIGURE 5 24 30 DIA Simplex Basin Angle A Should Be Between 30 60 36 And Larger Simplex...

Page 7: ...y line near the sanitary main by others A flexible pipe coupling Optional or ordered separately should also be installed at the basin The check valve should be of a flap style able to operate in a hor...

Page 8: ...direct burial cable through the coupling and into the junction box and tighten the grips on the box It is important to leave enough cable slack between the junction box and basin wall to allow the co...

Page 9: ...on the control panel label 3 turns past finger tight 6 Reference the Control Panel manual for panel wiring details After the coupling has been installed run the direct burial cable through the couplin...

Page 10: ...only cord locations cables color codes and junction box design may vary B Black OR Orange or BL Blue R Red G Green W White To make wire connections use the appropriate size wire nut B 8 LEVEL CONTROLS...

Page 11: ...n configuration This number is used for ordering and obtaining information C 3 MODEL NUMBER This designation consists of numbers and letters which represent the diameter depth and design This number i...

Page 12: ...place DBC Power 1 2 0 375 0 437 with 1 2 0 437 0 500 Standard 17 20 104049 Simplex 094687 Duplex SGV5002L SGV5022L Temp 6 4 1 010 8 4 0 780 14 2 0 530 Standard Using Extra Grommet 077843V 18 20 102736...

Page 13: ...e Control cable may not be used on all models FIGURE 16 Do to Direct Burial Cable availability a larger quantity of wires in the cable may be used and then removing those wires not being used DIRECT B...

Page 14: ...1Phase Control cable may not be used on all models FIGURE 17 Do to Direct Burial Cable availability a larger quantity of wires in the cable may be used and then removing those wires not being used DI...

Page 15: ...le Temp 5HP 1Phase w Temp Control cable may not be used on all models FIGURE 18 Do to Direct Burial Cable availability a larger quantity of wires in the cable may be used and then removing those wires...

Page 16: ...st Temp 5HP 1Phase w Moist Temp Control cable may not be used on all models FIGURE 19 Do to Direct Burial Cable availability a larger quantity of wires in the cable may be used and then removing those...

Page 17: ...ts and Two Control Cables Control Cables may not be used on all Pump Models FIGURE 20 Do to Direct Burial Cable availability a larger quantity of wires in the cable may be used and then removing those...

Page 18: ...e Pump Power Cable and 3 Floats FIGURE 21 Do to Direct Burial Cable availability a larger quantity of wires in the cable may be used and then removing those wires not being used DIRECT BURIAL CABLE CO...

Page 19: ...re Pump Power Cables and 4 Floats FIGURE 22 Do to Direct Burial Cable availability a larger quantity of wires in the cable may be used and then removing those wires not being used DIRECT BURIAL CABLE...

Page 20: ...Convertable Cover with Insert Convertable Cover Simplex System 20...

Page 21: ...5115 2 00 NPT PVC 089873 7 1 Nipple 24 30 Dia Basin 1 25 x Close NPT Stainless 075476 1 25 NPT x Close PVC 093925 Nipple 30 Dia Basin 2 00 NPT x Close Stainless 075478 2 00 NPT x Close PVC 093927 Nipp...

Page 22: ...pth 086242 108 Basin Depth 086244 120 Basin Depth 086246 132 Basin Depth 086248 144 Basin Depth 086250 156 Basin Depth 086252 24 2 Brace Right Stainless 24 Dia Basin 094944 30 Dia Basin 094945 36 Dia...

Page 23: ...Duplex System 23...

Page 24: ...l 48 Basin Depth 093980 60 Basin Depth 086236 72 Basin Depth 086238 84 Basin Depth 086240 90 Basin Depth 086241 96 Basin Depth 086242 108 Basin Depth 086244 120 Basin Depth 086246 132 Basin Depth 0862...

Page 25: ...1 Pipe Nipple 1 25 NPT x Close Stainless 075476 1 25 NPT x 1 62 Lg PVC 094914 2 NPT x Close Stainless 075478 2 NPT x Close PVC 093927 40 1 Vent Flange 2 026210A 41 6 Strain Relief Cable Grips STD Elec...

Page 26: ...NPT x 3 Lg Stainless 094903 2 50 NPT x 3 Lg PVC 094907 Pipe Nipple 48 Dia Basin 1 25 NPT x 8 50 Lg Stainless 094923 1 25 NPT x 6 Lg PVC 103473 2 50 NPT x 6 50 Lg Stainless 098413 2 50 NPT x 5 50 Lg PV...

Page 27: ...ial cable Volts rated 600V continuous use at 90C dry and 75C wet Cable to meet requirements of UL83 for THHN or THWN Jacket to be printed or indented size and number of conductors THHN or THWN TFFN ty...

Page 28: ...9 36 x 96 423 4 36 x 108 476 3 36 x 120 529 2 36 x 132 581 7 36 x 144 634 6 36 x 150 661 0 42 x 48 287 9 60 0 131 9 155 9 72 0 42 x 60 359 8 42 x 72 431 8 42 x 78 467 8 42 x 84 503 8 42 x 90 539 8 42...

Page 29: ...25 5 36 x 108 63 68 4011 9 28 7 36 x 120 70 75 4457 5 31 8 36 x 132 77 77 4899 7 35 0 36 x 144 85 00 5348 7 38 2 36 x 150 88 37 5567 7 39 8 42 x 48 38 49 2425 0 17 3 42 x 60 48 11 3030 6 21 6 42 x 72...

Page 30: ...f the warranty contact your local Crane Pumps Systems Inc Distributor RETURNED GOODS RETURN OF MERCHANDISE REQUIRES A RETURNED GOODS AUTHORIZATION CONTACT YOUR LOCAL CRANE PUMPS SYSTEMS INC DISTRIBUTO...

Page 31: ...ld testing if a conflict arises between the results of field testing conducted by or for user and laboratory tests corrected for field performance the latter shall control RECOMMENDATIONS FOR SPECIAL...

Page 32: ...Barnes Pressure Sewer Systems Piqua Ohio...

Reviews: