background image

Simplex System

11

1

Junction Box, NEMA 6

SGV

104049

SGV 5HP, 1PH

102736

SGPC

104047

Effluent

104048

12

1

J-Bolt

Stainless

058811

13

2

Flat Washer

1/4" Stainless

086538

14

1

Screw

1/4-20 x 1.50" Lg., Stainless

1-11-1

15

A/R

Sealant

16

1

Inlet, Flexible Pipe Fitting

4" Sch. 40 PVC, Grey

076149

4" SDR 35, PVC 

(STD)

, Maroon

075898

6" Sch. 40 PVC, Black

076941

6" SDR 35, PVC, Yellow

076111

Caulking Hub

4", Cast Iron

063847

Caulking Hub 

6", Cast Iron

063848

Caulking Hub

8", Cast Iron

063850

17

1

Lifting Device

Polypropylene Rope, Stainless Cable, Steel Chain

18

1

Handle

48" Deep

094780

60" Deep

094781

72" Deep

094782

78" Deep

094783

84" Deep

094784

90" Deep

094785

96" Deep

094786

108" Deep

094787

120" Deep

094788

144" Deep

097003

19

1

Mounting Bracket

Stainless

098714

20

2

Hex Hd Screw

1/4-20 x .75" Lg., Stainless

1-5-1

21

7

Lockwasher

1/4, or #10, Stainless

022333

22

8

Hex Nut

1/4-20, or #10, Stainless

15-5-1

23

1

"C" Channel, Stainless 

48" Basin Depth

093980

60" Basin Depth

086236

72" Basin Depth

086238

84" Basin Depth

086240

90" Basin Depth

086241

96" Basin Depth

086242

108" Basin Depth

086244

120" Basin Depth

086246

132" Basin Depth

086248

144" Basin Depth

086250

156" Basin Depth

086252

24

2

Brace, Right, Stainless

24" Dia. Basin

094944

30" Dia. Basin

094945

36" Dia. Basin

094947

42" Dia. Basin

094947

25

2

Brace, Left, Stainless

24" Dia. Basin

094948

30" Dia. Basin

094949

36" Dia. Basin

094950

42" Dia. Basin

094951

26

20

Hex Hd Screw

3/8-16 x 1.25"Lg., Stainless

022893

27

20

Flat washer

3/8, Stainless

082727

28

14

Lockwasher

3/8, Stainless

035729

29

14

Hex Nut

3/8-16, Stainless

15-23-1

30

8

Hex Nut

#10-32, Stainless

15-4-1

31

8

Lockwasher, IT

#10, Stainless

053421

32

1

Gasket, Pressure Sensitive, (Cover/Basin) 24" Dia. Basin (Not Shown) 

034452

33

1

RTV Adhesive

34

4

Weatherseal Washer, (Rail/Basin)

5/16, Stainless 

093952

35

4

Hex Hd Screw, (Rail/Basin)

5/16-18 x 1.25" Lg., Stainless

1-131-1

36

1

PST567 Adhesive

38

4

Hex Hd Screw

1/4-20 x 1.25" Lg., or #10, Stainless

104038

39

4

Weather Washer

1/4, or #10, Stainless/Buna-N

095032

45

3

Cable Grips (Not Shown), For Direct Burial Cable thru Basin.

1

Electrical Coupling, 1.25" (Not Shown) OPTIONAL

078470

1

Electrical Coupling, 1.50" (Not Shown) OPTIONAL

078471

1

Electrical Coupling, 2.00" (Not Shown) OPTIONAL

078471D

46

4

Pan Hd Self-Tapping Screw

#10- x 1.00" Lg., Stainless

102624

22

Summary of Contents for UltraGRIND

Page 1: ...Inc constant product improvement program product changes may occur As such Crane Pumps Systems Inc reserves the right to change product without prior written notification 420 Third Street P O Box 603...

Page 2: ...plex w Moist Temp 200 230V 1Ph 200 230 460V 3Ph Fig 17 14 SGV Simplex w Temp 5HP 200 230V 1Ph Fig 18 15 SGV Simplex w Moist Temp 5HP 200 230V 1Ph Fig 19 16 SGV Duplex 200 230V 1Ph 200 230 460V 3Ph Fig...

Page 3: ...es UltraGRIND grinder pump station The basin collects all wastewater from the house The solids in the sewage are then ground to a small size suitable for pumping in the slurry The grinder pump generat...

Page 4: ...rvicing 18 Only qualified personnel should install operate and repair pump 19 Keep clear of suction and discharge openings DO NOT insert fingers in pump with power connected 20 Do not pump hazardous m...

Page 5: ...the bottom of the basin and reach a compaction of 85 Standard Proctor Density See Figure 1 GRAVEL SPECIFICATION 1 A naturally rounded aggregate is required clean and free flowing with particle size n...

Page 6: ...Adapter or Caulking hub may be used in place of the flexible pipe fitting see Sections B 3 2 and B 3 3 TABLE For FIGURE 5 24 30 DIA Simplex Basin Angle A Should Be Between 30 60 36 And Larger Simplex...

Page 7: ...y line near the sanitary main by others A flexible pipe coupling Optional or ordered separately should also be installed at the basin The check valve should be of a flap style able to operate in a hor...

Page 8: ...direct burial cable through the coupling and into the junction box and tighten the grips on the box It is important to leave enough cable slack between the junction box and basin wall to allow the co...

Page 9: ...on the control panel label 3 turns past finger tight 6 Reference the Control Panel manual for panel wiring details After the coupling has been installed run the direct burial cable through the couplin...

Page 10: ...only cord locations cables color codes and junction box design may vary B Black OR Orange or BL Blue R Red G Green W White To make wire connections use the appropriate size wire nut B 8 LEVEL CONTROLS...

Page 11: ...n configuration This number is used for ordering and obtaining information C 3 MODEL NUMBER This designation consists of numbers and letters which represent the diameter depth and design This number i...

Page 12: ...place DBC Power 1 2 0 375 0 437 with 1 2 0 437 0 500 Standard 17 20 104049 Simplex 094687 Duplex SGV5002L SGV5022L Temp 6 4 1 010 8 4 0 780 14 2 0 530 Standard Using Extra Grommet 077843V 18 20 102736...

Page 13: ...e Control cable may not be used on all models FIGURE 16 Do to Direct Burial Cable availability a larger quantity of wires in the cable may be used and then removing those wires not being used DIRECT B...

Page 14: ...1Phase Control cable may not be used on all models FIGURE 17 Do to Direct Burial Cable availability a larger quantity of wires in the cable may be used and then removing those wires not being used DI...

Page 15: ...le Temp 5HP 1Phase w Temp Control cable may not be used on all models FIGURE 18 Do to Direct Burial Cable availability a larger quantity of wires in the cable may be used and then removing those wires...

Page 16: ...st Temp 5HP 1Phase w Moist Temp Control cable may not be used on all models FIGURE 19 Do to Direct Burial Cable availability a larger quantity of wires in the cable may be used and then removing those...

Page 17: ...ts and Two Control Cables Control Cables may not be used on all Pump Models FIGURE 20 Do to Direct Burial Cable availability a larger quantity of wires in the cable may be used and then removing those...

Page 18: ...e Pump Power Cable and 3 Floats FIGURE 21 Do to Direct Burial Cable availability a larger quantity of wires in the cable may be used and then removing those wires not being used DIRECT BURIAL CABLE CO...

Page 19: ...re Pump Power Cables and 4 Floats FIGURE 22 Do to Direct Burial Cable availability a larger quantity of wires in the cable may be used and then removing those wires not being used DIRECT BURIAL CABLE...

Page 20: ...Convertable Cover with Insert Convertable Cover Simplex System 20...

Page 21: ...5115 2 00 NPT PVC 089873 7 1 Nipple 24 30 Dia Basin 1 25 x Close NPT Stainless 075476 1 25 NPT x Close PVC 093925 Nipple 30 Dia Basin 2 00 NPT x Close Stainless 075478 2 00 NPT x Close PVC 093927 Nipp...

Page 22: ...pth 086242 108 Basin Depth 086244 120 Basin Depth 086246 132 Basin Depth 086248 144 Basin Depth 086250 156 Basin Depth 086252 24 2 Brace Right Stainless 24 Dia Basin 094944 30 Dia Basin 094945 36 Dia...

Page 23: ...Duplex System 23...

Page 24: ...l 48 Basin Depth 093980 60 Basin Depth 086236 72 Basin Depth 086238 84 Basin Depth 086240 90 Basin Depth 086241 96 Basin Depth 086242 108 Basin Depth 086244 120 Basin Depth 086246 132 Basin Depth 0862...

Page 25: ...1 Pipe Nipple 1 25 NPT x Close Stainless 075476 1 25 NPT x 1 62 Lg PVC 094914 2 NPT x Close Stainless 075478 2 NPT x Close PVC 093927 40 1 Vent Flange 2 026210A 41 6 Strain Relief Cable Grips STD Elec...

Page 26: ...NPT x 3 Lg Stainless 094903 2 50 NPT x 3 Lg PVC 094907 Pipe Nipple 48 Dia Basin 1 25 NPT x 8 50 Lg Stainless 094923 1 25 NPT x 6 Lg PVC 103473 2 50 NPT x 6 50 Lg Stainless 098413 2 50 NPT x 5 50 Lg PV...

Page 27: ...ial cable Volts rated 600V continuous use at 90C dry and 75C wet Cable to meet requirements of UL83 for THHN or THWN Jacket to be printed or indented size and number of conductors THHN or THWN TFFN ty...

Page 28: ...9 36 x 96 423 4 36 x 108 476 3 36 x 120 529 2 36 x 132 581 7 36 x 144 634 6 36 x 150 661 0 42 x 48 287 9 60 0 131 9 155 9 72 0 42 x 60 359 8 42 x 72 431 8 42 x 78 467 8 42 x 84 503 8 42 x 90 539 8 42...

Page 29: ...25 5 36 x 108 63 68 4011 9 28 7 36 x 120 70 75 4457 5 31 8 36 x 132 77 77 4899 7 35 0 36 x 144 85 00 5348 7 38 2 36 x 150 88 37 5567 7 39 8 42 x 48 38 49 2425 0 17 3 42 x 60 48 11 3030 6 21 6 42 x 72...

Page 30: ...f the warranty contact your local Crane Pumps Systems Inc Distributor RETURNED GOODS RETURN OF MERCHANDISE REQUIRES A RETURNED GOODS AUTHORIZATION CONTACT YOUR LOCAL CRANE PUMPS SYSTEMS INC DISTRIBUTO...

Page 31: ...ld testing if a conflict arises between the results of field testing conducted by or for user and laboratory tests corrected for field performance the latter shall control RECOMMENDATIONS FOR SPECIAL...

Page 32: ...Barnes Pressure Sewer Systems Piqua Ohio...

Reviews: