background image

3

Please Read This Before Installing Or Operating Pump. 
This information is provided for 

SAFETY and to PREVENT 

EQUIPMENT PROBLEMS

. To help recognize this information, 

observe the following symbols:

IMPORTANT!

 Warns about hazards that can result 

in personal injury or Indicates factors concerned with 
assembly, installation, operation, or maintenance which 
could result in damage to the machine or equipment if 
ignored.

CAUTION !

 Warns about hazards that can or will cause minor 

personal injury or property damage if ignored. Used with symbols 
below.

WARNING !

  Warns about hazards that can or will cause serious 

personal injury, death, or major property damage if ignored. Used 
with symbols below.

Only qualifi ed personnel should install, operate and repair 
pump. Any wiring of pumps should be performed by a qualifi ed 
electrician.  

WARNING ! -

 To reduce risk of electrical shock, pumps 

and control panels must be properly grounded in 
accordance with the National Electric Code (NEC) or the 
Canadian Electrical Code (CEC) and all applicable state, 
province, local codes and ordinances. 

WARNING! -

 To reduce risk of electrical shock, always 

disconnect the pump from the power source before 
handling or servicing. Lock out power and tag.

WARNING!

 Operation against a closed 

discharge valve will cause premature bearing 
and seal failure on any pump, and on end 
suction and self priming pump the heat build 

may cause the generation of steam with resulting dangerous 
pressures. It is recommended that a high case temperature 
switch or pressure relief valve be installed on the pump body.

CAUTION !

 Never operate a pump with a plug-in  type 

power cord without a ground fault  circuit interrupter.

CAUTION! 

Pumps build up heat and pressure 

during operation-allow time for pumps to cool 
before handling or servicing. 

WARNING!

 - 

DO NOT

 pump hazardous materials 

(fl ammable, caustic, etc.) unless the pump is specifi cally 
designed and designated to handle them.

Do not block or restrict discharge hose, as discharge 
hose may whip under pressure. 

WARNING! - DO NOT

 wear loose clothing that may 

become entangled in the impeller or other moving parts. 

WARNING! - 

Keep clear of suction and discharge 

openings. 

DO NOT

 insert fi ngers in pump with power 

connected.

Always wear eye protection when working on pumps.

Make sure lifting handles are securely fastened each 
time before lifting. 

DO NOT

 operate pump without 

safety devices in place. Always replace safety devices 
that have been removed during service or repair. 
Secure the pump in its operating position so it can not 
tip over, fall or slide.

DO NOT

 exceed manufacturers recommendation for 

maximum performance, as this could cause the motor 
to overheat.

DO NOT

 remove cord and strain relief. Do not connect 

conduit to pump.

WARNING!

 Cable should be protected at all times to 

avoid punctures, cut, bruises and abrasions - inspect 
frequently. Never handle connected power cords with 
wet hands.

WARNING!

 To reduce risk of electrical shock, all wiring 

and junction connections should be made per the NEC 
or CEC and applicable state or province and local 
codes. Requirements may vary depending on usage 
and location.

WARNING!

 Submersible Pumps are not approved for 

use in swimming pools, recreational water installations, 
decorative fountains or any installation where human 
contact with the pumped fl uid is common.

WARNING! 

Products Returned Must Be Cleaned, 

Sanitized, Or Decontaminated As Necessary Prior 
To Shipment, To Insure That Employees Will Not Be 
Exposed To Health Hazards In Handling Said Material. 
All Applicable Laws And Regulations Shall Apply.

 

Bronze/brass and bronze/brass fi tted pumps may 
contain lead levels higher than considered safe for 
potable water systems. Lead is known to cause cancer 
and birth defects or other reproductive harm. Various 
government agencies have determined that leaded 
copper alloys should not be used in potable water 
applications. For non-leaded copper alloy materials of 
construction, please contact factory. 

IMPORTANT! -

 Crane Pumps & Systems, Inc. is not 

responsible for losses, injury, or death resulting from a 
failure to observe these safety precautions, misuse or 
abuse of pumps or equipment.

SAFETY FIRST!

Hazardous fl uids can 
cause fi re or explo-
sions, burnes or death 
could result.

Extremely hot - Severe 
burnes can occur on contact.

Biohazard can cause 
serious personal injury.

Hazardous fl uids can Hazard-
ous pressure, eruptions or ex-
plosions could cause personal 
injury or property damage.

Rotating machinery
Amputation or severe 
laceration can result.

Hazardous voltage can 
shock, burn or cause death.

Manual Index

Summary of Contents for 8DSE-HL Series

Page 1: ...occur As such Crane Pumps Systems reserves the right to change product without prior written noti cation 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 89...

Page 2: ...ED VIEW Fig 10 15 PARTS LIST 16 18 RETURNED GOODS POLICY 19 WARRANT 20 START UP REPORT 21 22 WARRANTY REGISTRATION SPECIAL TOOLS AND EQUIPMENT INSULATION TESTER MEGGER DIELECTRIC TESTER SEAL TOOL KIT...

Page 3: ...ngers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety devices...

Page 4: ...pressure equalized reservoir Material Rotating Faces Carbon Stationary Faces Ceramic Elastomer Buna N Hardware 300 series stainless steel CORD ENTRY 25 Ft 8m Cord Epoxy sealed housing with secondary...

Page 5: ...5 inches mm NOTE PUMP DISCHARGE CAN BE ROTATED IN 45 INCREMENTS Manual Index...

Page 6: ...C 2 Discharge Discharge piping should be as short as possible Both a check valve and a shut off valve are recommended for each pump being used The check valve is used to prevent back ow into the sump...

Page 7: ...st should be performed on the motor The resistance values ohms as well as the voltage volts and current amps should be recorded on the start up report D 3 3 Pump Down Test After the pump has been prop...

Page 8: ...e motor housing to compensate for oil expansion see Fig 9 Set unit upright and ll only until the motor as viewed through the conduit box opening is just covered and no more Reassemble the O ring 11 co...

Page 9: ...ors 12 and 17 The wiring connections should be noted to insure correct connections when reassembling Remove cap screws 19 and hex nuts 20 Vertically lift the outside motor housing 2 from bearing brack...

Page 10: ...HREE PHASE 460 575 VOLT AC THREE PHASE 460 575 VOLT AC Power Cable 10A Power Cable 10A Motor Lead Number Motor Lead Number Green 3 Ground Green Black 1 Red 2 White 3 4 7 Together 5 8 Together 6 9 Toge...

Page 11: ...s in seal plate 25 Check moisture sensor probes 18 for damage Replace by disconnecting wires 16 by removing screws 14 and lockwashers 15 Then remove probe 18 from bearing bracket 21 Seal To expose sha...

Page 12: ...39 into bearing bracket 21 and tighten Fill seal chamber with oil as outlined in paragraph F 1 3 SECTION G REPLACEMENT PARTS G 1 ORDERING REPLACEMENT PARTS When ordering replacement parts ALWAYS furni...

Page 13: ...ler for freedom of operation security and condition Clean impeller and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so th...

Page 14: ...14 FIGURE 9 Manual Index...

Page 15: ...15 FIGURE 10 Manual Index...

Page 16: ...Cable Not Sold Separately 10b 1 052259 Gland Nut 10c 2 052261 Friction Ring 10d 1 052262 Grommet 10e 1 Control Cable Not Sold Separately 10f 1 051448 Gland Nut 10g 1 021531 Friction Ring 10h 1 066871...

Page 17: ...46 Shaft Key 3 8 Sq x 2 1 4 lg Stainless 35 1 102698 Washer 625 x 2 Stainless 36 4 018926 Lockwasher 3 8 Stainless 37 4 084885 Stud 3 8 16 x 4 1 2 lg Steel 38 4 15 23 6 Nut 3 8 16 Zp Steel 39 4 036803...

Page 18: ...1 0000186 Gasket 63 1 105294 Stand 64 1 0082528 Base Elbow 10 65 1 0082530 Hand Hole Cover 66 2 0000479 Capscrew 7 8 9 x 1 50 Lg Stainless 68 1 092871 Gasket Buna S 69 12 002312 Capscrew 7 8 9 x 3 50...

Page 19: ...re That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclose...

Page 20: ...tees in the nature of performance speci cations furnished in addition to the foregoing material and workmanship warranties on a product manufactured by us if any are subject to laboratory tests correc...

Page 21: ...impeller turn freely by hand Yes No Condition of equipment Good Fair Poor Condition of cable jacket Good Fair Poor Resistance of cable jacket Good Fair Poor Resistance of cable and pump motor measured...

Page 22: ...ump Off L1 L2 L2 L3 L3 L1 Voltage supply at panel line connection Pump On L1 L2 L2 L3 L3 L1 Amperage Load connection Pump On L1 L2 L3 FINAL CHECK Is pump seated on discharge properly Check for leaks D...

Page 23: ...STATE ZIP MODEL NO SERIAL NO PART NO BRAND IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty Complete the Warranty Registration Form and return to Crane Pumps Systems In...

Page 24: ...CRANE PUMPS SYSTEMS INC WARRANTY SERVICE GROUP 420 THIRD STREET PIQUA OHIO 45356 U S A FOLD HERE AND TAPE DO NOT STAPLE PLACE STAMP HERE Manual Index...