Barnes 4SE-DS series Installation And Operation Manual Download Page 27

FOLD HERE AND TAPE, DO NOT STAPLE

**IMPORTANT!**

WARRANTY REGISTRATION

CUSTOMER’S 

NAME 

     DATE 

INSTALLED

ADDRESS

CITY   

 

 

 

 

STATE 

 

 

 

 

ZIP

PHONE 

       FAX 

#

DEALER’S NAME

CITY   

 

 

 

 

STATE 

 

 

 

 

ZIP

MODEL 

NO. 

    SERIAL 

NO.

PART 

NO. 

    BRAND

IMPORTANT!

WARRANTY REGISTRATION

Your product is covered by the enclosed Warranty.

Complete the Warranty Registration Form and return to

Crane Pumps & Systems, Inc. Warranty Service Group

If you have a claim under the provision of the warranty, contact your local 

Crane Pumps & Systems, Inc. Distributor.

Summary of Contents for 4SE-DS series

Page 1: ...product improvement program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written noti cation 420 Third Street 83 West Drive Bramton Piqua O...

Page 2: ...7 DOUBLE SEAL CROSS SECTION Fig 17 18 DOUBLE SEAL EXPLODED VIEW Fig 18 19 PARTS LIST 20 22 RETURNED GOODS POLICY 23 WARRANTY 24 START UP REPORT 25 26 WARRANTY REGISTRATION SPECIAL TOOLS AND EQUIPMENT...

Page 3: ...insert ngers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety d...

Page 4: ...l Filled Squirrel Cage Induction Insulation Class B SINGLE PHASE Permanent Split Capacitor PSC Includes overload protection in motor THREE PHASE 200 240 480 is Tri voltage motor 600V Requires overload...

Page 5: ...out vanes on Back side Dynamically balanced ISO G6 3 Material Cast Iron ASTM A 48 Class 30 SHAFT 416 Stainless Steel SQUARE RINGS Buna N HARDWARE 300 Series Stainless Steel PAINT Air dry enamel top co...

Page 6: ...n or basin shall be vented in accordance with local plumbing codes This pump is designed to pump sewage ef uent or other nonexplosive or noncorrosive wastewater and shall NOT be installed in locations...

Page 7: ...ntinuous Amperes Inrush Amperes 110 120 3 00 30 0 220 240 1 50 15 0 440 480 0 75 7 5 600 0 60 6 0 C 4 3 Moisture Sensors DS Models Optional A normally open N O detector is installed in the pump seal c...

Page 8: ...1 13 7 15 4 14 4 SOW 0 570 14 5 5 49 6 28 4SE1944DS 1 9 480 3 60 1750 B 2 5 7 7 14 4 SOW 0 570 14 5 21 96 24 51 4SE1954DS 1 9 600 3 60 1750 C 1 9 7 2 14 4 SOW 0 570 14 5 34 36 35 60 Winding Resistanc...

Page 9: ...e gauge assembly and tighten into hole see Figure 3 Pressurize motor housing to 10 P S I Use soap solution around the sealed areas above the oil level and inspect joints for air bubbles For sealed are...

Page 10: ...ation disassemble volute and impeller as outlined in paragraph F 2 1 If further repair is required remove retaining ring 28d spring 28c and rotating member 28b from shaft see Figures 5 6 Examine all s...

Page 11: ...tor and Bearing Service F 4 1 Disassembly and Inspection To examine or replace the motor 7 capacitor 9 single phase units controls 56 optional and bearing 25 drain oil from motor as outlined in paragr...

Page 12: ...ce department Bearings When replacing bearing be careful not to damage the rotor or shaft threads Clean the shaft thoroughly Press bearing 25 on the motor shaft position squarely onto the shaft applyi...

Page 13: ...ragraph G 2 4 Part description 5 Item part number 6 Quantity required 7 Shipping instructions 8 Billing Instructions G 2 PART NUMBER The part number consists of a six 6 digit number which appears in t...

Page 14: ...14 FIGURE 13 CONTIUED...

Page 15: ...Check cutter for freedom of operation security and condition Clean cutter and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is se...

Page 16: ...16 FIGURE 15 4SE L Series Single Seal...

Page 17: ...17 FIGURE 16 4SE L Series Single Seal...

Page 18: ...18 FIGURE 17 4SE DS Series Double Seal...

Page 19: ...19 FIGURE 18 4SE DS Series Double Seal...

Page 20: ...1 034964 Capacitor 30MFD 1 Phase 10 1 039858 Capacitor Bracket 1 Phase 11 4 1 129 1 Hex Hd Cap Screw Std 5 16 18 x 75 Lg Stainless 6 1 129 1 Hex Hd Cap Screw Optional for moisture and temp sensors 12...

Page 21: ...46TR 4 00 Dia 34 3 005808 Nipple 35 3 003479 Cap 36 1 027344 Gasket 39 1 014270 Pipe Plug 375 NPT ZP 41 A R Loctite242 42 A R Permatex2C 44 1 003217 Pipe Plug All double seal 25 NPT ZP 45 2 5 32 6 Scr...

Page 22: ...ature Sensor 3 Phase or Moisture Sensor 8 FT 103756A 103741A 103742A 103741A 103740A 15 FT Std 103756 103741 103742 103741 103740 20 FT 103756XA 103741XA 103742XA 103741XA 103740XA 30 FT 103756XC 1037...

Page 23: ...o Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the e...

Page 24: ...guarantees in the nature of performance speci cations furnished in addition to the foregoing material and workmanship warranties on a product manufactured by us if any are subject to laboratory tests...

Page 25: ...m Does impeller turn freely by hand Yes No Condition of equipment Good Fair Poor Condition of cable jacket Good Fair Poor Resistance of cable jacket Good Fair Poor Resistance of cable and pump motor m...

Page 26: ...ction Pump Off L1 L2 L2 L3 L3 L1 Voltage supply at panel line connection Pump On L1 L2 L2 L3 L3 L1 Amperage Load connection Pump On L1 L2 L3 FINAL CHECK Is pump seated on discharge properly Check for...

Page 27: ...CITY STATE ZIP MODEL NO SERIAL NO PART NO BRAND IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty Complete the Warranty Registration Form and return to Crane Pumps Syst...

Page 28: ...CRANE PUMPS SYSTEMS INC WARRANTY SERVICE GROUP 420 THIRD STREET PIQUA OHIO 45356 U S A FOLD HERE AND TAPE DO NOT STAPLE PLACE STAMP HERE...

Reviews: