![Barnes 4SE-DS series Installation And Operation Manual Download Page 13](http://html1.mh-extra.com/html/barnes/4se-ds-series/4se-ds-series_installation-and-operation-manual_475310013.webp)
13
Press the terminal block (21) into the housing so it seats
completely below the snap ring groove. Place snap ring (19)
into groove in cable entry bore of housing. Repeat terminal
block installation for control cable, if equipped.
F-4.4) Cable Assemblies:
Power/Control Cable-
Refi
ll the cooling oil as outlined
in paragraph F-1.3. Make wire connections as outlined in
paragraph F-4.3. Insert female end of cable plug into housing
bore aligning timing mark with hole in terminal block (21) see
Figure 14. Compress cable plug with compression fl ange
(16a) by tightening hex bolts (11) into the housing (6). Torque
to 132 in-lbs.
SECTION: G REPLACEMENT PARTS
G-1 ORDERING REPLACEMENT PARTS:
When ordering replacement parts, ALWAYS furnish the
following information:
1. Pump serial number and date code. (Paragraph G-4)
2. Pump model number. (Paragraph G-3)
3. Pump part number. (Paragraph G-2)
4. Part description.
5. Item part number.
6. Quantity required.
7. Shipping instructions.
8. Billing Instructions.
G-2 PART NUMBER:
The part number consists of a six (6) digit number, which
appears in the catalog. A one or two letter suffi x may follow
this number to designate the design confi guration. This
number is used for ordering and obtaining information.
G-3 MODEL NUMBER:
This designation consists of numbers and letters which
represent the discharge size, series, horsepower, motor
phase and voltage, speed and pump design. This number is
used for ordering and obtaining information.
G-4 SERIAL NUMBER:
The serial number block will consist of a six digit number,
which is specifi c to each pump and may be preceded by
a alpha character, which indicates the plant location. This
number will also be suffi xed with a four digit number, which
indicates the date the unit was built (Date Code).
EXAMPLE: A012345 0490.
Reference the six digit portion (Serial Number) of this number
when referring to the product.