SECTION B: GENERAL INFORMATION

B-1) To the Purchaser:

 

Congratulations! You are the owner of one of the fi nest pumps 
on the market today. CP&S pumps are products engineered 
and manufactured of high quality components. Over one 
hundred years of pump building experience along with a 
continuing quality assurance program combine to produce a 
pump which will stand up to the toughest applications. This 
manual will provide helpful information concerning installation, 
maintenance, and proper service guidelines.

B-2) Receiving:

 

Upon receiving the pump, it should be inspected for damage 
or shortages. If damage has occurred, fi le a claim immediately 
with the company that delivered the pump. If the manual 
is removed from the packaging, do not lose or misplace.

B-3) Storage:
Short Term-

 CP&S Pumps are manufactured for effi cient 

performance following short inoperative periods in storage. 
For best results, pumps can be retained in storage, as factory 
assembled, in a dry atmosphere with constant temperatures 
for up to six (6) months. Long Term- Any length of time 
exceeding six (6) months, but not more than twenty-four (24) 
months. The unit should be stored in a temperature controlled 
area, a roofed over walled enclosure that provides protection 
from the elements (rain, snow, wind-blown dust, etc.), and 
whose temperature can be maintained b40 deg. F 
and +120 deg. F. (4.4 - 49°C). Pump should be stored in its 
original shipping container. On initial start up, rotate impeller 
by hand to assure seal and impeller rotate freely. If it is 
required that the pump be installed and tested before the long 
term storage begins, such installation will be allowed provided:

1.)  The pump is not installed under water for more than
 

one (1) month.

2.)  Immediately upon satisfactory completion of the test,
 

the pump is removed, thoroughly dried, repacked in the

 

original shipping container, and placed in a temperature

 

controlled storage area.

B-4) Service Centers:

 

For the location of the nearest Barnes Service Center, check 
your Barnes representative or Crane Pumps & Systems, Inc., 
Service Department in Piqua, Ohio, telephone (937) 778-8947 
or Crane Pumps & Systems Canada, in Brampton, Ontario, 
(905) 457-6223.

SECTION C: INSTALLATION

C-1) Location:

These pumping units are self-contained and are recommended 
for use in a sump, lift station or basin. This pump is designed 
to pump unscreened raw sewage, sludges, slurries, primary 
and secondary tank de-slugging, storm overfl ow, wood pulp, 
animal hide and fl eshings, vegetable waste, or other non-
explosive or non-corrosive applications and shall NOT be 
installed in locations classifi ed as hazardous in accordance 
with the National Electrical Code (NEC), ANSI/NFPA 70 or the 
Canadian Electrical Code. Never install the pump in a trench, 
ditch or hole with a dirt bottom; it will sink into the dirt and the 
suction will become plugged.

C-1.1 Submergence:

It is recommended that the pump be operated in the 
submerged condition and the sump liquid level should never 
be less than dimension “A” in Figure 1.

C-2) Discharge:

Discharge piping should be as short as possible. Both a check 
valve and a shut-off valve are recommended for each pump 
being used. The check valve is used to prevent backfl ow into 
the sump. Excessive backfl ow can cause fl ooding and/or 
damage to the pump. The shut-off valve is used to stop 
system fl ow during pump or check valve servicing.

Barnes Pumps supplies a breakaway fi tting discharge system 
designed to allow the submersible cutter pump to be installed 
or removed without requiring personnel to enter the wet well.

Place the Break Away Fitting (BAF) in position. Temporarily 
secure the guide rails in the upper mounting brackets and 
locate the base on the bottom of the wet well. Level the base 
with grout and/or shims. Install the intermediate support 
brackets, if required. Make sure the rails are in a true vertical 
position so the pump will clear the access opening and 
will slide freely down the rails into place on the discharge 
stationary fi tting. Once the rails are in proper alignment, bolt 
the base into the fl oor of the station and connect the discharge 
pipe to the elbow. Connect the movable portion and other 
supplied fi ttings of the BAF onto the pump and lower into wet 
well. See the Break Away Fitting manual for more information.

C-3) Liquid Level Controls:

The level controls are to be supported by a mounting bracket 
that is attached to the sump wall, cover or junction box. Cord 
grips are used to hold the cords in place on the mounting 
bracket. The control level can be changed by loosening 
the grip and adjusting the cord length as per the plans and 
specifi cations. Be certain that the level controls cannot 
hang up or foul in it’s swing and that the pump is completely 
submerged when the level control is in the “Off” mode.

FIGURE 1

Recommended
Submergence
Level

Minimum
Submergence
Level

A = 13”

Bottom

Summary of Contents for 4SCC Series

Page 1: ...e product without prior written noti cation 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www c...

Page 2: ...16 17 CROSS SECTION 180 Mtr FRame Fig 10 18 PARTS LIST 19 20 RETURNED GOODS POLICY 21 WARRANTY 22 START UP REPORT 23 24 WARRANTY REGISTRATION SPECIAL TOOLS AND EQUIPMENT INSULATION TESTER MEGGER DIELE...

Page 3: ...insert ngers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety d...

Page 4: ...Ball Grease Lubricated Load Radial LOWER BEARING Design Double Row Ball Grease Lubricated Load Radial Thrust MOTOR Design NEMA B Three Phase Torque Curve Air Filled Squirrel Cage Induction Insulation...

Page 5: ...4SCE 4 2HP 25 23 641 17 27 439 6 77 172 7 95 202 16 00 404 4 80 122 4SCE 12 9 17 7HP 31 81 808 17 27 439 6 77 172 7 95 202 16 00 404 4 82 123 4SCF 4 2HP 25 90 658 18 49 470 7 13 181 1 7 95 202 16 00 4...

Page 6: ...designed to pump unscreened raw sewage sludges slurries primary and secondary tank de slugging storm over ow wood pulp animal hide and eshings vegetable waste or other non explosive or non corrosive a...

Page 7: ...rick moisture detection relay part number 1D1EO is an acceptable panel mounted relay See Figure 2 for typical wiring diagram In the event of a moisture detect the pump should be pulled and the source...

Page 8: ...0 1750 H 14 4 80 0 14 4 SO 0 570 15 4SCD4844A 4 8 460 3 60 1750 H 7 2 40 0 14 4 SO 0 570 15 4SCD7134A 7 1 230 3 60 1750 H 19 4 114 0 8 4 SO 0 780 20 4SCD7144A 7 1 460 3 60 1750 H 9 7 57 0 8 4 SO 0 780...

Page 9: ...aco Diala Oil AX Woco Premium 100 F 1 2 Testing Oil 1 Check oil for contamination using an oil tester with a range to 30 Kilovolts breakdown 2 If oil is found to be clean and uncontaminated measure ab...

Page 10: ...bly F 3 1 Disassembly Loosen cable connectors 32 and 35 inspect connectors and replace if required Remove cable box cover 5 from motor housing 1 by removing cap screws 19 and washers 20 Remove cable l...

Page 11: ...th at screw driver Upper Seal Remove lower seal as outlined above Remove screws 17 and washers 18 and remove intermediate 2 from motor housing 1 being careful not to damage o ring 21 or sensor probe 3...

Page 12: ...acement is required remove bearing 12 from motor shaft using a wheel puller Remove snap ring 8 or screws 19 with washers 20 from bearing bracket 3 and remove bearing bracket 3 Now remove snap ring 15...

Page 13: ...he design con guration This number is used for ordering and obtaining information G 3 MODEL NUMBER This designation consists of numbers and letters which rep resent the discharge size series horsepowe...

Page 14: ...impeller for freedom of operation security and condition Clean impeller and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set...

Page 15: ...15 FIGURE 9 Pump Series 4SCC 4SCD 4SCE 4SCF 100 132 Mtr Frame...

Page 16: ...Box Cover 6 1 Rotor 7 1 Stator 8 1 Snap Ring 9 1 Upper Shaft Seal 10 1 Lower Shaft Seal 11 1 Lower Bearing 12 1 Upper Bearing 15 1 Snap Ring 16 1 Key 17 2 Screw 18 2 Washer 19 6 Screw 20 6 Washer 21 1...

Page 17: ...34A 4844A 100 PA PB 7 68 195mm 7 48 190mm 7 09 180mm 095488 095488TA 095488TB STD 4SCE4236A 4246A 100 PA PB PC 9 06 230mm 8 66 220mm 8 27 210mm 7 87 200mm 095489 095489TA 095489TB STD 095489TC 4SCE129...

Page 18: ...18 FIGURE 10 Pump Series 4SCF 180 Mtr Frame...

Page 19: ...Washer 21 1 O Ring 23 1 Drain Plug 25 1 Snap Ring 26 1 Screw 27 1 Washer 29 25ft Power Cable 30 1 Ground 31 3 Wire Connector 32 2 Cable Connector 33 1 Wire Connector 34 25ft Control Cable 35 1 Cable...

Page 20: ...ut 60 1 O ring 61 2 Nut TABLE 3 CUTTER IMPELLER Item No 41 PUMP MODEL MOTOR CASING ADDED SUFFIX TO BASIC PART NO IMPELLER DIA IMPELLER PART NO 4SCF29734A 29744A 180 PA PB PC 10 43 256mm 10 04 255mm 9...

Page 21: ...o Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the e...

Page 22: ...guarantees in the nature of performance speci cations furnished in addition to the foregoing material and workmanship warranties on a product manufactured by us if any are subject to laboratory tests...

Page 23: ...m Does impeller turn freely by hand Yes No Condition of equipment Good Fair Poor Condition of cable jacket Good Fair Poor Resistance of cable jacket Good Fair Poor Resistance of cable and pump motor m...

Page 24: ...ction Pump Off L1 L2 L2 L3 L3 L1 Voltage supply at panel line connection Pump On L1 L2 L2 L3 L3 L1 Amperage Load connection Pump On L1 L2 L3 FINAL CHECK Is pump seated on discharge properly Check for...

Page 25: ...Notes...

Page 26: ...Notes...

Page 27: ...CITY STATE ZIP MODEL NO SERIAL NO PART NO BRAND IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty Complete the Warranty Registration Form and return to Crane Pumps Syst...

Page 28: ...CRANE PUMPS SYSTEMS INC WARRANTY SERVICE GROUP 420 THIRD STREET PIQUA OHIO 45356 U S A FOLD HERE AND TAPE DO NOT STAPLE PLACE STAMP HERE...

Reviews: