Barnes 4SCC Series Installation And Operation Manual Download Page 4

4

DISCHARGE  .................................  

4” NPT, 125 lb. Flange Horizontal

LIQUID TEMPERATURE ...............

104°F (40°C) Continuous

VOLUTE  ........................................

Cast Iron ASTM A-48, Class 40B

MOTOR HOUSING ........................

Cast Iron ASTM A-48, Class 25

SEAL PLATE .................................

Cast Iron ASTM A-48, Class 25

IMPELLER:

  

Design 

 ......................

2 Port, Enclosed,  Dynamically

  

 

 

Balanced ISO G6.3

 

Material 

 ....................

Austenitic Cast Iron, ASTM A436-80-55-06

CUTTER CONE ..............................

Integral with Impeller, Hardened Steel 

  

  52/53 

Rockwell 

"C"

CUTTER BLADE ............................

Hardened Steel, 45/47 Rockwell "C"

SHAFT 

 

 ..........................................

416 Stainless Steel

SQUARE RINGS ............................

Buna-N

LIFTING DEVICE ........................... Y

oke

HARDWARE ..................................

300 Series Stainless Steel

PAINT  ............................................

Air Dry Enamel.

SEAL: 

 

Design

 

 ......................

Tandem Mechanical, Oil Filled Reservoir

Material Inbord

  ......................

Rotating Faces - Carbon

 

 

 

Stationary Faces - Stainless Steel

 

 

 

Elastomer - Buna-N

 

 

 

Hardware -300 Series Stainless

 

Outbord

 ....................

Rotating Faces - Tungsten Carbide

 

 

 

Stationary Faces - Tungsten Carbide

 

 

 

Elastomer - Buna-N

 

 

 

Hardware -300 Series Stainless

CORD ENTRY ................................

30 ft. (9m) Std. Cord. Pressure Grommet

 

 

 

 for Sealing and Strain Relief

SPEED ...........................................  

1150 and 1750 RPM (Nominal)

UPPER BEARING:

 

 

Design

 

 ......................  

Single Row, Ball, Grease Lubricated

 

Load

 

  

......................

Radial

LOWER BEARING:

 

 

Design

 

 ......................  

Double Row, Ball, Grease Lubricated

 

Load

  

......................

Radial & Thrust

MOTOR:

  

Design

 

 ......................  

NEMA B - Three Phase Torque Curve.

 

 

 

 Air-Filled, Squirrel Cage Induction 

 

Insulation

 ..................

 

Class F.

THREE PHASE ..............................  

Dual Voltage 230/460; Includes 

 

 

 

 Overload Protection in Motor.

MOISTURE SENSOR ....................  

Normally Open (N/O), Requires Relay in

  

   

Control 

Panel

TEMPERATURE SENSOR ............  

Normally Closed (N/C), Requires Relay in

  

   

Control 

Panel

OPTIONAL EQUIPMENT ...............  

Seal Material, Impeller Trims, 

  

   

Cord 

Length

SECTION: A - PUMP SPECIFICATIONS:

IMPORTANT !

1.)  PUMP MAY BE OPERATED “DRY” FOR EXTENDED PERIODS WITHOUT DAMAGE TO MOTOR AND/OR SEALS. 
2.)  THIS PUMP IS APPROPRIATE FOR THOSE APPLICATIONS SPECIFIED AS CLASS I DIVISION II HAZARDOUS LOCATIONS. 
3.)  THIS PUMP IS NOT APPROPRIATE FOR THOSE APPLICATIONS SPECIFIED AS CLASS I DIVISION I HAZARDOUS LOCATIONS.
4.) INSTALLATIONS SUCH AS DECORATIVE FOUNTAINS OR WATER FEATURES PROVIDED FOR VISUAL ENJOYMENT MUST BE INSTALLED IN 
 

ACCORDANCE  WITH THE NATIONAL ELECTRIC CODE ANSI/NFPA 70 AND/OR THE AUTHORITY HAVING JURISDICTION. THIS PUMP IS NOT 

 

INTENDED FOR USE IN SWIMMING POOLS, RECREATIONAL WATER PARKS, OR INSTALLATIONS IN WHICH HUMAN CONTACT WITH PUMPED 

 

MEDIA IS A COMMON OCCURRENCE.

Summary of Contents for 4SCC Series

Page 1: ...e product without prior written noti cation 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www c...

Page 2: ...16 17 CROSS SECTION 180 Mtr FRame Fig 10 18 PARTS LIST 19 20 RETURNED GOODS POLICY 21 WARRANTY 22 START UP REPORT 23 24 WARRANTY REGISTRATION SPECIAL TOOLS AND EQUIPMENT INSULATION TESTER MEGGER DIELE...

Page 3: ...insert ngers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety d...

Page 4: ...Ball Grease Lubricated Load Radial LOWER BEARING Design Double Row Ball Grease Lubricated Load Radial Thrust MOTOR Design NEMA B Three Phase Torque Curve Air Filled Squirrel Cage Induction Insulation...

Page 5: ...4SCE 4 2HP 25 23 641 17 27 439 6 77 172 7 95 202 16 00 404 4 80 122 4SCE 12 9 17 7HP 31 81 808 17 27 439 6 77 172 7 95 202 16 00 404 4 82 123 4SCF 4 2HP 25 90 658 18 49 470 7 13 181 1 7 95 202 16 00 4...

Page 6: ...designed to pump unscreened raw sewage sludges slurries primary and secondary tank de slugging storm over ow wood pulp animal hide and eshings vegetable waste or other non explosive or non corrosive a...

Page 7: ...rick moisture detection relay part number 1D1EO is an acceptable panel mounted relay See Figure 2 for typical wiring diagram In the event of a moisture detect the pump should be pulled and the source...

Page 8: ...0 1750 H 14 4 80 0 14 4 SO 0 570 15 4SCD4844A 4 8 460 3 60 1750 H 7 2 40 0 14 4 SO 0 570 15 4SCD7134A 7 1 230 3 60 1750 H 19 4 114 0 8 4 SO 0 780 20 4SCD7144A 7 1 460 3 60 1750 H 9 7 57 0 8 4 SO 0 780...

Page 9: ...aco Diala Oil AX Woco Premium 100 F 1 2 Testing Oil 1 Check oil for contamination using an oil tester with a range to 30 Kilovolts breakdown 2 If oil is found to be clean and uncontaminated measure ab...

Page 10: ...bly F 3 1 Disassembly Loosen cable connectors 32 and 35 inspect connectors and replace if required Remove cable box cover 5 from motor housing 1 by removing cap screws 19 and washers 20 Remove cable l...

Page 11: ...th at screw driver Upper Seal Remove lower seal as outlined above Remove screws 17 and washers 18 and remove intermediate 2 from motor housing 1 being careful not to damage o ring 21 or sensor probe 3...

Page 12: ...acement is required remove bearing 12 from motor shaft using a wheel puller Remove snap ring 8 or screws 19 with washers 20 from bearing bracket 3 and remove bearing bracket 3 Now remove snap ring 15...

Page 13: ...he design con guration This number is used for ordering and obtaining information G 3 MODEL NUMBER This designation consists of numbers and letters which rep resent the discharge size series horsepowe...

Page 14: ...impeller for freedom of operation security and condition Clean impeller and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set...

Page 15: ...15 FIGURE 9 Pump Series 4SCC 4SCD 4SCE 4SCF 100 132 Mtr Frame...

Page 16: ...Box Cover 6 1 Rotor 7 1 Stator 8 1 Snap Ring 9 1 Upper Shaft Seal 10 1 Lower Shaft Seal 11 1 Lower Bearing 12 1 Upper Bearing 15 1 Snap Ring 16 1 Key 17 2 Screw 18 2 Washer 19 6 Screw 20 6 Washer 21 1...

Page 17: ...34A 4844A 100 PA PB 7 68 195mm 7 48 190mm 7 09 180mm 095488 095488TA 095488TB STD 4SCE4236A 4246A 100 PA PB PC 9 06 230mm 8 66 220mm 8 27 210mm 7 87 200mm 095489 095489TA 095489TB STD 095489TC 4SCE129...

Page 18: ...18 FIGURE 10 Pump Series 4SCF 180 Mtr Frame...

Page 19: ...Washer 21 1 O Ring 23 1 Drain Plug 25 1 Snap Ring 26 1 Screw 27 1 Washer 29 25ft Power Cable 30 1 Ground 31 3 Wire Connector 32 2 Cable Connector 33 1 Wire Connector 34 25ft Control Cable 35 1 Cable...

Page 20: ...ut 60 1 O ring 61 2 Nut TABLE 3 CUTTER IMPELLER Item No 41 PUMP MODEL MOTOR CASING ADDED SUFFIX TO BASIC PART NO IMPELLER DIA IMPELLER PART NO 4SCF29734A 29744A 180 PA PB PC 10 43 256mm 10 04 255mm 9...

Page 21: ...o Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the e...

Page 22: ...guarantees in the nature of performance speci cations furnished in addition to the foregoing material and workmanship warranties on a product manufactured by us if any are subject to laboratory tests...

Page 23: ...m Does impeller turn freely by hand Yes No Condition of equipment Good Fair Poor Condition of cable jacket Good Fair Poor Resistance of cable jacket Good Fair Poor Resistance of cable and pump motor m...

Page 24: ...ction Pump Off L1 L2 L2 L3 L3 L1 Voltage supply at panel line connection Pump On L1 L2 L2 L3 L3 L1 Amperage Load connection Pump On L1 L2 L3 FINAL CHECK Is pump seated on discharge properly Check for...

Page 25: ...Notes...

Page 26: ...Notes...

Page 27: ...CITY STATE ZIP MODEL NO SERIAL NO PART NO BRAND IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty Complete the Warranty Registration Form and return to Crane Pumps Syst...

Page 28: ...CRANE PUMPS SYSTEMS INC WARRANTY SERVICE GROUP 420 THIRD STREET PIQUA OHIO 45356 U S A FOLD HERE AND TAPE DO NOT STAPLE PLACE STAMP HERE...

Reviews: