background image

A Crane Co. Company

BARNES

BARNES

®

INSTALLATION and OPERATION MANUAL

Self-Priming Centrifugal Pumps

IMPORTANT! 

Read all instructions in this manual before operating pump.

 

As a result of Crane Pumps & Systems, Inc., constant product improvement program,

 

product changes may occur. As such Crane Pumps & Systems reserves the right to 

 

change product without prior written notifi cation.

420 Third Street   

 

83 West Drive, Bramton

Piqua, Ohio 45356 

 

Ontario, Canada L6T 2J6

Phone: (937) 778-8947 

 

Phone: (905) 457-6223

Fax: (937) 773-7157 

 

Fax: (905) 457-2650

www.cranepumps.com

Form No. 104613-Rev. G

Model: 2020HC

Manual Index

Summary of Contents for 2020HC

Page 1: ...s Systems Inc constant product improvement program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 104613 Rev G Model 2020HC Manual Index ...

Page 2: ...NED GOODS POLICY 11 WARRANT 12 START UP REPORT 13 15 WARRANTY REGISTRATION Other brand and product names are trademarks or registered trademarks of their respective holders Barnes is a registered trademark of Crane Pumps Systems Inc 1998 2002 10 04 4 06 9 06 Alteration Rights Reserved WARNING The engine exhaust from this product contains chemicals know to the State of California to cause cancer bi...

Page 3: ...de DO NOT exceed manufacturers recommendation for maximum performance as this could cause the motor to overheat When towing pump behind a vehicle make sure hitch is properly attached always attach safety chains WARNING If Engine driven never operate in an enclosed building or area where exhaust gases can accumulate Never operate near a building where exhaust gases can seep inside Never operate in ...

Page 4: ...lve Flap Neoprene Weights Cast Iron ASTM A 48 Class 30 BASE Steel with Carring Handles STRAINER 2 51mm Suction Steel PRIMER Exhaust with 0 150 PSI Compound Pressure and Vacuum Gauge ENGINE Make Model Briggs Stratton 245400 Gasoline Type 4 Cycle Single Cylinder Air Cooled Displacement 24 Cu In Oil Capacity 51 Fl Oz Air Cleaner Dual Element Fuel Tank 7 5 Quarts Start Method Recoil Rope Rated Max Dyn...

Page 5: ...ld be located as near as possible to the liquid to be pumped and in no case should the pump be more than 15 feet above the surface of the liquid supply The pump should always be as level as possible C 2 Suction System Connect suction pipe or hose to suction inlet If hose is used it should be of the reinforced type to prevent collapsing under suction Make sure all suction system connections are tig...

Page 6: ...intermediate coupling slide rotating member 9B onto shaft sleeve until lapped faces of 9A and 9B are together If finger pressure is not sufficient use a piece of tubing making sure to press ONLY on bellows tail section not on metal retainer See Figure 2 Make sure driving lugs in retainer are mated in carbon washer Place spring 9C on shaft sleeve and in place on rotating member 9B making sure it is...

Page 7: ...on head higher than pump designed for 4 Insufficient inlet pressure or suction head 5 Clogged foot valve strainer or pump 6 Defective wearplate s 1 Repair or replace suction line 2 Refill reprime pump casing before restarting 3 Lower suction head install foot valve and primer 4 Increase inlet pressure by adding more water to tank or increasing back pressure by turning gate valve on discharge line ...

Page 8: ...8 Figure 3 ...

Page 9: ...16 8 002501 Hex Nut 5 16 18 17 3 015000 Pipe Plug 375 NPT 18 1 021857 Check Valve Assy 18a 1 001338 Weight 2 25 Not Shown 18b 1 001339 Weight 1 56 Not Shown 18c 1 021577 Gasket Not Shown 18d 1 023469 RdHd Screw 1 4 20 x 625 Lg 19 1 021041 Check Valve Body 20 4 1 92 6 Capscrew 5 8 11 x 1 50 Lg 22 1 011113 Gage Compound 0 150 PSI 1 104823 Base Assy 24 1 021924 Base Channel LH 25 1 021925 Base Channe...

Page 10: ...22562 Lock Pin 187 Dia x 875 Lg H 1 2 22009 10 Pan Hd Self Tapping Screw 6 32 Steel I 1 104606 Tee Red 1 00 x 75 x 50 NPT CI J 1 104602 Adapter Assy K 1 011123 Union Half 375 NPT x 1 50 Lg Brass L 2 011124 Flare Nut 625 18 UNC 2B Brass M 1 104617 Tube 375 Dia x 18 Lg Copper N 1 022835 Tube Assy w Elbow 25 NPT O 1 104827 Gasket Graphite P 1 104826 Support Plate Steel Q 4 2 63 1 Rd Hd Screw 8 32 x 5...

Page 11: ...rformance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccuracies in field testing if a conflict arises between the results of field testing conducted by or for user and laboratory tests corrected for field performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FROM SYSTEMS ANALYSES AND EVALUAT...

Page 12: ...ent To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty To complete the Warranty Registration Form go to http www cranepumps com ProductRegistration If you have a claim under the provision of the warranty contact your local Crane Pump...

Reviews: