4
DISCHARGE ..................
1½” (38mm) x 1½ (38mm) NPT ,
Female
LIQUID TEMPERATURE
160°F (71°C) Continuous
INTERMEDIATE .............
Cast Iron ASTM A-48, Class 30
VOLUTE .........................
Cast Iron ASTM A-48, Class 30
BODY .............................
Cast Iron ASTM A-48, Class 30
PEDESTAL .....................
Cast Iron ASTM A-48, Class 30
IMPELLER
Design ...........
Semi-Open
Material ........
Cast Iron ASTM A-48, Class 30
Dynamically Balanced, ISO G6.3
SHAFT ............................
Stainless Steel
SQUARE RINGS ............
Buna-N
HARDWARE ..................
300 Series Stainless Steel
PAINT .............................
Air dry enamel
SEAL
Design ..........
Mechanical
Lubrication....
Self-Lubrication
Material ........
Rotating Faces - Carbon
Stationary Faces - Ceramic
Elastomer - Buna-N
Hardware - 300 series stainless steel
CHECK VALVE:
Material ........
Valve Flap - Neoprene
Weight - Cast Iron ASTM A-48, Class 30
MOTOR:
Design ..........
ODP,
NEMA L, Single phase,
NEMA B, Three Phase Torque Curve,
C-Face, Footed, Squirrel Cage
Induction
Insulation ......
Class B
SINGLE PHASE .............
Dual Voltage 115/230, capacitor
start
THREE PHASE ..............
200-240/480 is Tri voltage motor.
OPTIONAL EQUIPMENT:
Seal Material, TEFC motors
SECTION: A - PUMP SPECIFICATIONS: 3CCE, 4CCE, 5CCE
inches
(mm)
MODEL
NO.
HP
VOLTS
PH
RPM
(Nom)
ODP MOTOR DESIGN
TEFC MOTOR DESIGN
* A
DIM
FULL
LOAD
AMPS
LOCKED
ROTOR
AMPS
WEIGHT
NET LBS
* A
DIM
FULL
LOAD
AMPS
LOCKED
ROTOR
AMPS
3CCE
1.5
200-230/460
3
3450
17.88 (454)
6.0/3.0
40/20
84
20.00 (508)
5-4.6/2.3
36/18
3CCE-1
1.5
115/230
1
3450
18.44 (468)
4.5/2.3
12/60
84
21.00 (534)
16.6/8.3
84/42
4CCE
2.0
200-230/460
3
3450
18.44 (468)
6.8/3.4
50/25
92
21.00 (534)
7-5.4/2.7
46/23
4CCE-1
2.0
115/230
1
3450
18.44 (468)
5.9/3.0
144/72
92
21.92 (557)
23/11.5
156/78
5CCE
3.0
200-230/460
3
3450
18.44 (468)
9.6/4.8
64/32
94
21.92 (557)
8.1-7.6/3.8
66/33
5CCE-1
3.0
115/230
1
3450
19.69 (500)
8.3/4.2
204/102
94
25.36 (644)
29/14.5
172/86
IMPORTANT!
1.)
DO NOT
USE FOR PUMPING FLUIDS WITH A FLASH POINT OF LESS THAN 100°F.
2.) MAKE CERTAIN THAT PUMP AND/OR MOTOR ASSEMBLY AND CONTROLS HAVE THE APPROPRIATE RATINGS FOR THE GIVEN
APPLICATION AREA CLASSIFICATION (ie DIVISION I, AGENCY LISTING ETC.)
“A” - Overall Dimensions subject to Motor Manufacture
Summary of Contents for 10CCE
Page 12: ...12 SERIES 3CCE 3CCE 1 4CCE 4CCE 1 5CCE 5CCE 1...
Page 13: ...13 SERIES 3CCE 3CCE 1 4CCE 4CCE 1 5CCE 5CCE 1...
Page 15: ...15 SERIES 10CCE 10CCE 1...
Page 16: ...16 SERIES 10CCE 10CCE 1...
Page 18: ...18 SERIES 15CCE 20CCE 25CCE...
Page 19: ...19 SERIES 15CCE 20CCE 25CCE...