Note: Metal head of electrode will be ON when touching the water, OFF when leaving water.
Water-level control mode
a.
When the pump is power on, if floating switch (or water-level detector) is "ON", it means the pump starts to
work.
b.
In the running of the pump, if floating switch (or water-level detector) is "OFF", it means the pump will stop
working after 60 s continuous working, but if floating switch (or water-level detector) is "ON" again in 60 s after
"OFF", the pump will be non-stop.
c.
Stop time: After the pump stops for low water-level, it will not start within 60 s, even if floating switch (or water-
level detector) is ON, unless plug in the power again after power off.
d.
Recovery mode: The pump stops for low water-level, it will start when floating switch (or water-level detector)
is ON.
No.
Category
Set
value
Actuation
time (s)
Recovery
time (s)
Recovery mode (s)
1
2
3
4
6
5
7
8
Phase loss
Impeller jam
Phase
sequence
protection
Over-current
protection
Low-voltage
protection
Over-voltage
protection
Temperature
protection
Water level
control
—
Double
rated
current
With power
line input
errors, the
pump won’t
work.
≥ 1.2 times
rated current
≤ 323 V
Winding
≥ 257 ± 41 °F
Stated
otherwise
2
0.1
—
30
5
5
0.1
—
Manually recovery (manually
turn off the power, correct
and turn on the power).
Manually recovery (manually
turn off the power, correct
and turn on the power).
Manually recovery (manually
turn off the power, correct
and turn on the power).
Automatic
recovery
Automatic
recovery
Automatic
recovery
Automatic
recovery
≤ 176 ± 50 °F
≥ 460 V
—
—
—
300
300
300
—
—
—
13
2.5 Technical data and function