06
Installation
barmesapumps.com
Figure 2
Wrong installation.
Without
strainer
Vortex
"D"
Too much
height
Less than
4 "D"
Long piping
Concentric
reducer
Air
Air leaks
A valve in the suction pipe
is not recommended
Piping elbow immediately
installed after the suction
Suction height
- suction pipe should
have a slope of 0.39" per 3.3 ft of
suction. Never exceed 16.4 ft suction,
considering friction.
(Figure 3)
Positive/Drowned Suction
- A gate
valve is installed in the suction pipe
to service the pump
(Figure 4)
. Volute
or body have plugs, and these must
be removed to allow trapped air to
escape.
Use
pipe
or
hose
reinforced
sufficiently
robust
to
prevent
destruction due to high pressure.
4
Discharge pipe
Due to the cost of energy or BHP
necessary to overcome the friction
generated by using a smaller
diameter pipe, a larger diameter
discharge pipe is commonly used
than the required by the volute or
body.
Figure 3
Inclination.
Correct
Incorrect
Air pocket
0.39" of inclination
per 3.28 ft
Figure 4
Positive suction.
Check valve
(completely open)
"D"
6 "D" min.
Pressurized water
Correct
Figure 5
Positive suction.
A retention valve in the suction pipe
is not recommended. If required,
better install the valve in the
discharge pipe.
Valve partially
closed
Incorrect