background image

7

Maintenance

Ÿ

Repeat pattern until all the bolts 
have  been  completely  tighten. 
Do not over tighten this bolts, it 
may  damage  the  pumps  casing 
and stationary seal.

Ÿ

Once the stationary part and the 
seal  plate  have  been  installed, 
using  silicon  lubricant,  lightly 
lubricate  the  Viton  seal  O-ring. 
This  will  help  to  position  the 
assembly down the shaft.

Ÿ

Inspect the pump shaft and look 
for  imperfections  that  may 
damage  the  mechanical  seal  O-
ring.  In  case  you  find  one  make 
sure 

to 

correct 

this 

imperfections.

Ÿ

Slide  the  rotating  assembly 
carefully  down  the  pump  shaft 
onto the stationary seal.

Ÿ

Install the collar, lock washer and 
cap screw and place a wrench on 
the  hole  in  the  pump  shaft  to 
keep it from rotating, tighten the 
cap screw.

Ÿ

Place the key on the motor shaft 
and pump shaft.

Ÿ

Identify the coupling half that is 
machined  to  receive  the  two 
shafts  keys.  Slide  the  coupling 
between  the  two  shafts  and 
position  the  motor  collar  in  the 
coupling.  (motor  collar  was  not 
removed)

Ÿ

To connect the pump shaft collar 
to  the  coupling  half  you  will 
need  to  slightly  raise  the  shaft 
using  an  Allen  key  or  a  wrench 
inserted in the shaft hole.

Ÿ

Place  the  second  half  of  the 
coupling and insert the coupling 
bolts and washers. Hand tighten 
them at this point.

Ÿ

 Make sure both motor shaft and 
pump shaft rotate freely.

Ÿ

Adjust  the  mechanical  seal 
rotating  assembly  on  top  of  the 
stationary  seal  and  tighten  the 
set screw.

Ÿ

Remove the holding clips with a 
small flat head screwdriver.

Ÿ

Open  discharge  and  suction 
valves and make sure the pump 
is primed.

Ÿ

To ensure a proper priming, open 
the  plug  in  the  mechanical  seal 
lubrication line until liquid starts 
bursting  out,  then  close  it.  Now 
you  can  re-energize  the  motor 
and reconnect the power supply.

barmesa.com

Summary of Contents for BVL Series

Page 1: ...intenance Manual Split Coupled Vertical In line Pumps BVL series 1 500 HP IMPORTANT Read all instructions in this manual before operating or servicing a pump Last update 07 15 2021 8 x 8 x 13 3 x 3 x...

Page 2: ...wer source before DANGER handling any aspect of the pumping system Lockoutpowerandtag Do not lift carry or hang pump by the electrical cables Damage to the electrical cables can cause DANGER shock bur...

Page 3: ...LER Closetype castironASTMA 48class30orbronzeASTM B584 Gr C84400 SPLITCOUPLING Aluminum6061 T6 SHAFT StainlessSteel416 COUPLING CastironASTMA 48class30 MECHANICALSEAL Carbon SiliconCarbide Viton SS304...

Page 4: ...eiving Installation 4Suction Recommended to use robust and self supported piping and inspect for any leakage For a successful installation you need to rely on the friction loss calculation in the suct...

Page 5: ...DDITIONAL PIPE SUPPORTS FLO TREX VALVE FLO TREX VALVE FLOOR SADDLE SUPPORT Installation STANCHION PLATES SEISMICALLY RATED SNUBBERS SEISMICALLY RATED SNUBBERS OR PADS AND CONCRETE OR PADS AND CONCRETE...

Page 6: ...ion Due to the high energy cost or BHP necessary to overdue friction generated by using a small diameter pipe usually a large diameter pipe is used in the discharge side Piping valves etc should be pe...

Page 7: ...supply so the motor doesn t not accidentally start Close the suction and discharge valve and drain the remaining liquid by removing the plug once all the liquid is drained reinstall the plug Remove t...

Page 8: ...pump shaft Identify the coupling half that is machined to receive the two shafts keys Slide the coupling between the two shafts and position the motor collar in the coupling motor collar was not remov...

Page 9: ...NECTION GLAND MECH SEAL BOLT LOCKWASHER ITEM 62 EXPLODEDVIEW OUTBOARD MECH SEAL STATIONARY SEAT MECHANICAL SEAL ITEM 62A ITEM 62B ITEM 52 ITEM 163 ITEM 62 When ordering repair parts always provide the...

Page 10: ...ECHANICAL SEAL ROTARY PART FLUSH CONNECTOR COUPLING OR STUFFING BOX GLAND MECH SEAL BOLT LOCKWASHER PUMP S SHAFT RETAINING RING ITEM 160 MECHANICAL SEAL STATIONARY FACE EXPLODEDVIEW INBOARD MECH SEAL...

Page 11: ...4 405 TSC 2 2 31030506 30405008 284 286 TC 1 31030505 30405009 324 326 TC 2 31030506 364 365 TC 445 447 TSC 30405011 182 184 TC 1 2 31030502 30405012 213 215 TC 1 2 31030503 30405013 254 256 TC 1 1 31...

Page 12: ...1 21 9 7 28 1 86 0 6 180 757 66 3 26 7 8 9 2 27 0 73 0 3 200 833 80 32 2 10 07 2 72 0 87 0 35 220 908 95 38 1 12 6 3 21 1 03 0 41 240 984 111 44 5 14 7 3 74 1 2 0 48 260 1060 128 51 3 16 9 4 3 1 38 0...

Page 13: ...3 36 STANDARD 45 ELBOW 0 38 0 54 0 61 0 77 0 92 1 15 1 53 1 83 2 29 STANDARD TEE 1 68 2 29 2 75 3 36 4 28 5 19 6 71 8 23 10 1 ANGLE GLOBE VALVE OPEN 3 97 5 49 6 71 8 23 10 7 12 2 16 8 21 3 25 9 GLOBE...

Page 14: ...13 Exploded View COUPLING BUSHING 51 50 SUBASSEMBLY 163 21 36 80 83 86 IMPELLER SHAFT SUBASSEMBLY barmesa com...

Page 15: ...14 Exploded View VERTICAL IN LINE PUMP IMPELLER SHAFT COUPLING BUSHING 101 102 105 100 102 103 104 SUBASSEMBLY SUBASSEMBLY barmesa com...

Page 16: ...15 Exploded View MECHANICAL SEAL FLUSH 163 62B 62A 148 156 54 62 PUMP S SHAFT 52 155 DISCHARGE S FLANGE SUCTION S FLANGE 62 58 58 68 67 63 59 barmesa com...

Page 17: ...CLASS 30 101 CASING GASKET NON ASBESTOS OR TEFLON PTFE 102 GAUGE PLUG GALVANIZED STEEL 103 CASING CAPSCREW 104 WASHER 105 CASING DRAIN PLUG GALVANIZED STEEL OR CAST IRON 140 COUPLING ALUMINIO 6061 T6...

Page 18: ...1 Thepumpspeedisverylow 2 Mechanicaldefects Thevoltageiscorrect Theinternalpartsforwear D The pump priming good vacuum gauge reading is almost normal reading in the manometerisgreater 1 Dischargeobstr...

Page 19: ...18 barmesa com...

Reviews: