background image

5

Recommendations & Warnings

4

Receiving inspection

Upon  receiving  the  pump,  it  should 
be  inspected  for  damage  or 
shortages.  If  damage  has  occurred, 
file  a  claim  immediately  with  the 
company that  delivered the pump. If 
the  manual  is  removed  from  the 
packaging, do not lose or misplace.

4

Storage

Any  product  that  is  stored  for  a 
period  longer  than  six  (6)  months 
from the date of purchase should be 
bench  tested  prior  to  installation.  A 
bench  test  consists  of,  checking  the 
impeller  to  assure  it  is  free  turning 
and  a  run  test  to  assure  the  motor 
(and  switch  if  provided)  operate 
properly.

4

Service Stations

To  find  the  nearest  Barmesa  Pumps 
authorized  service  shop,  please 
directly  contact  your  distributor  or 
the factory.

**See friction table in pipes and fittings 
to  determine  the  dimensions  of  the 
suction and discharge. (Page 7)

At any time exceeding six (6) months, 
but  no  more  than  twenty  four  (24), 
the  equipment  must  be  stored  in  a 
controlled area, keeping it away from 
contact  with  rain,  dust,  etc.,  and  the 
temperature  is  maintained  between 
43-104  °F.  If  there  is  a  possibility  of 
high  humidity  (coastlines,  etc.),  the 
entire  unit  must  be  sprayed  with 
antioxidant liquid.

4

Installation

(

See Figure  1 for  better  reference

). The 

pump should be as close as possible 
to  the  liquid  to  be  pumped,  with  a 
minimum  number  of  couplings, 
adapters,  etc.,  in  order  to  reduce 
friction on the suction side.

A  successful  operation  depends  on 
the  calculation  of  the  friction  loss  in 
the  suction,  considering  acceptable 
limits. The minimum suction pipe size 
to  use  can  be  determined  by 
comparing the NPSH available at the 
pump  suction  against  the  NPSH 
required by the impeller, as shown in 
the performance curves.

Usually, we recommend using a pipe 
diameter of 1/2" to 1" greater as that 
of the suction volute or body.

A strainer or sieve should be installed 
in the suction to prevent the entry of 
objects. The strainer must have a free 
entry  area  at  least  three  times  the 
pipe diameter. Usually a suction valve 
is combined with a strainer 

Figure 1

.

Use  pipe  or  hose  reinforced 
sufficiently 

robust 

to 

prevent 

collapsing  by  the  difference  in 
atmospheric pressure. Check for leaks 
at all joints.

4

Suction

The  anchors  of  the  motor  are  to  be 
anchor, 

on 

raised 

base, 

approximately  4",  this  to  prevent 
accumulated water from entering the 
motor.

The  suction  and  discharge  piping 
must  be  perfectly  aligned  in  the 
pump 

volute 

and 

supported 

independently  using  support  or 
anchors,  this  to  prevent  excessive 
load on the volute.

Figure 1

Proper installation.

Motor

Anchors

Base

Pipe

support

Eccentric

reducer

Vacuum

gauge

 Straight pipping as short as possible, but not less
than 6 times the "D" diameter

Perfectly sealed joints

As close 

as possible

As close 

as possible

Strainer

 Appropriate size "D"

to avoid the excess

of friction

1 "D"

min

4 "D"

min

Suction

valve

Suction

valve

4"

"D"

barmesa.com

Summary of Contents for BCS 1 1/4x1 1/2-5

Page 1: ...ion Centrifugal Stainless Steel Pumps IMPORTANT Read all instructions in this manual before operating or servicing a pump Last update 07 15 2021 BCS series 0 5 HP 1750 RPM 0 75 3 HP 3500 RPM BCSF seri...

Page 2: ...impeller can causeseriousinjury Always wear eye protection when working on pumps Do not wear loose clothing that may become entangled in moving parts Pumps build up heat and pressure during operation...

Page 3: ...mediatecoupling 4BCS SERIES 2 50 1 59 SINGLE PHASE ONLY 6 31 MAX 6 50 2 50 L 1 NPT OPTIONAL 2 88 3 38 SUCTION DISCHARGE W C MAX 0 41 DIA HOLES 4 PLACES 3 50 X 4 12 2 94 2 94 6 75 4 88 MAX R 2 66 Dimen...

Page 4: ...protectionmustbeprovided HARDWARE AISI304stainlesssteel PAINT Solventbasedenamel onlyintermediatecoupling 4BCSF SERIES AB APPROX Z X E E A D G APPROX MAX 17 8 W BG C MAX O MAX F F B H HOLES 4 R L D Mo...

Page 5: ...M A AB B All dimensions are in inches and weight in pounds Do not use for construction purposes Pumps will be shipped with top vertical discharge position as standard For other orientations remove cas...

Page 6: ...educe friction on the suction side A successful operation depends on the calculation of the friction loss in the suction considering acceptable limits The minimum suction pipe size to use can be deter...

Page 7: ...d by using a smaller diameter pipe a larger diameter discharge pipe is commonly used than the required by the volute or body Figure 2 Wrong installation Without strainer Vortex D Too much height Less...

Page 8: ...MPORTANT Do not operate pump without priming first Operating dry will damage seal 4Pre Operation 1 Check Voltage and Phase Compare the voltage and phase information stamped on the pump name plate 2 Ch...

Page 9: ...en the pump for inspection or cleaning DO NOT remove the seal only remove the spring if the impeller had to be removed Once a seal has been in operation it is very difficult that when removing and rea...

Page 10: ...54 1 21 9 7 28 1 86 0 6 180 757 66 3 26 7 8 9 2 27 0 73 0 3 200 833 80 32 2 10 07 2 72 0 87 0 35 220 908 95 38 1 12 6 3 21 1 03 0 41 240 984 111 44 5 14 7 3 74 1 2 0 48 260 1060 128 51 3 16 9 4 3 1 38...

Page 11: ...75 3 36 STANDARD 45 ELBOW 0 38 0 54 0 61 0 77 0 92 1 15 1 53 1 83 2 29 STANDARD TEE 1 68 2 29 2 75 3 36 4 28 5 19 6 71 8 23 10 1 ANGLE GLOBE VALVE OPEN 3 97 5 49 6 71 8 23 10 7 12 2 16 8 21 3 25 9 GL...

Page 12: ...11 Spare Parts To request a replacement please provide the model and serial number as shown on the nameplate and the description and part number as shown in the parts list 4BCS barmesa com...

Page 13: ...ller BCS 3 94 03140237I Impeller BCS 3 75 03140237J Impeller BCS 3 50 5 03180031 Seal plate BCS 1 CF8M 6 30400840B Shaft sleeve BCS 1 316 SS 7 31030287 Mechanical seal 7 8 1 0114SVP6SS 8 30400530 Base...

Page 14: ...ANICAL SEAL ROTATORY PART MECHANICAL SEAL MECHANICAL SEAL STATIONARY PART STATIONARY PART MECHANICAL SEAL STATIONARY PART To request a replacement please provide the model and serial number as shown o...

Page 15: ...teel 17 92010040H Housing gasket 2 257 1 Viton 18 92010014 Deflector washer 1 Buna N 19 94010061E Identification plate BCSF 1 Aluminum 20 91010192 Rivet 001628 SS 2 Stainless steel ITEM PART DESCRIPTI...

Page 16: ...1 91010345C Hex screw 3 8 x 1 2 304 SS 12 91010413 Hex screw 3 8 x 1 4 Steel 13 91010012 Spring washer 3 8 4 Steel 14 91010061 Spring washer 3 8 10 304 SS 15 92010030G Impeller gasket 0 025 2 Viton 16...

Page 17: ...n on the nameplate and the description and part number as shown in the parts list 4BCSF AK 8 MECHANICAL SEAL MECHANICAL SEAL ROTATORY PART ROTATORY PART MECHANICAL SEAL ROTATORY PART MECHANICAL SEAL M...

Page 18: ...sket 2 265 1 Viton 18 92010014 Deflector washer 1 Buna N 19 94010061E Identification plate BCSF 1 Aluminum 20 91010192 Rivet 001628 SS 2 Stainless steel 4BCSF 1 x 2 8 with flange 8 ITEM PART DESCRIPTI...

Page 19: ...mping capacity is not too much The pump is operating in the range of NPSHR If reducing flow makes the noise gone then the problem is in the point above partially close the discharge valve The bearings...

Page 20: ...19 barmesa com...