background image

1

Before installation, read the following 

instructions  carefully.  Failure  to 
follow 

instruction 

and 

safety 

information  could  cause  serious 

bodily  injury,  death  and/or  property 
damage.  Each  Barmesa  product  is 

carefully  inspected  to  insure  proper 
performance. Closely following these 

instructions  will  eliminate  potential 

operating  problems,  assuring  years 

of trouble-free service. 

General Safety Information

IMPORTANT! - Barmesa Pumps is not 
responsible  for  losses,  injury  or 
death  resulting  from  failure  to 

observe  these  safety  precautions, 
misuse,  abuse  or  misapplication  of 
pumps or equipment.

Installation,  wiring,  and 

junc tion  connec tions  must  be  in 

accordance  with  the  National  Electric 
Code  and  all  applicable  state  and  local 
codes. Requirements may vary depending 
on usage and location.

WARNING

I n s t a l l a t i o n   a n d 

servicing  is  to  be  conducted  by 

qualified personnel only.

WARNING

D o   n o t

  u s e   t h e s e 

pumps  in  water  over  104º  F. 

Do  not

 

exceed manufacturers recommended 

maximum performance, as this could 

cause the motor to overheat.

WARNING

Ground  Fault  Circuit 

Interrupter  (GFCI)  to  be  used  with 

plug-in type power cord.

WARNING

A L L   R E T U R N E D 

P R O D U C T S   M U S T   B E 
CLEANED,  SANITIZED,  OR

DECONTAMINATED  PRIOR  TO 

S H I P M E N T ,   T O   I N S U R E 

E M P L O Y E E S   W I L L   N O T   B E 
EXPOSED TO HEALTH HAZARDS IN 

HANDLING  SAID  MATERIAL.  ALL 

A P P L I C A B L E   L A W S   A N D 

REGULATIONS  SHALL  APPLY.

Keep  clear  of  suction  and 

discharge  openings.  Do  not 

insert  fingers  in  pump  with

power connected; the rotating cutter 

and/or  impeller  can  cause  serious 

injury.

Always  wear  eye  protection 
when working on pumps. Do 

not wear loose clothing that

may  become  entangled  in  moving 
parts.

Pumps  build  up  heat 

and  pressure  during 
operation.  Allow  time 

fo r   p u m p s   t o   c o o l

DANGER

before  handling  or  servicing  the 
pump  or  any  accessor y  items 

associated with or near the pump.

T h i s   p u m p   i s   n o t 

i n t e n d e d   f o r   u s e   i n 

swimming  pools  or  water 

installations  where  there  is

DANGER

human contact with pumped fluid.

Risk of electric shock. To 

reduce risk of electric shock, 

always  disconnect  pump 

from  power  source  before

DANGER

handling any aspect of the pumping 
system.

 Lock out power and tag.

Do  not

  lift,  carry  or 

hang pump by the electrical 

c a b l e s.   D a m a g e   to   t h e 
electrical  cables  can  cause

DANGER

shock, burns or death. 

Never

 handle 

connected  power  cords  with  wet 
hands. Use appropriate lifting device.

S u m p   a n d   s e w a g e 

pumps often handle materials which 

could  cause  illness  or  disease.  Wear 
adequate  protective  clothing  when 

working  on  a  used  pump  or  piping. 

Never enter a basin after it has been 
used.

WARNING

Failure  to  permanently 

ground the pump, motor and 

controls  before  connecting 

to  power  can  cause  shock,

DANGER

burns or death.

These pumps are not to 

be  installed  in  locations 
classified  as  hazardous  in 

accordance with the National

Electric Code, ANSI/NFPA 70.

DANGER

The  Uniform  Plumbing 

Code  (UPC)  states  that  sewage 

systems shall have an audio and visual 

alarm that signals a malfunction of the 
systems,  that  are  required  to  reduce 

the potencial for property damage.

WARNING

1 Phase Models

Amps:

Volts:

3 Phase Models

Amps L1-2:

Volts L1-2:

Amps L2-3:

Volts L2-3:

Amps L3-1:

Volts L3-1:

Model Number: _____________________

Serial: ____________

PHASE: ______ HP: __________________

IMPORTANT!  -  Prior  to  installation, 
record  Model  Number,  Serial,  Amps, 

Voltage,  Phase  and  HP  from  pump 
name  plate  for  the  future  reference. 

Also  record  the  Voltage  and  Current 

Readings at Startup:

WARNING

 "Danger" indicates an 

imminently  hazardous  situation 

which, if not avoided, WILL result in 

death or serious injury.

"Warning"  indicates 

an  imminenty  hazardous  situation 

which, if not avoided, MAY result in 

death or serious injury.

"Caution"  indicates  a 

potentially  hazardous  situation 

which, if not avoided, MAY result in 
minor or moderate injury.

DANGER

CAUTION

barmesa.com

Summary of Contents for 6BSE-LDS Series

Page 1: ...Handling Pumps IMPORTANT Read all instructions in this manual before operating or servicing a pump 6BSE HLDS 30 60 HP 6BSE LDS 9 30 HP 18 60 HP Last update 10 08 2021 6BSE LDS 6BSE HLDS series 9 12 18...

Page 2: ...he pump or any accessory items associatedwithornearthepump T h i s p u m p i s n o t i n t e n d e d f o r u s e i n swimming pools or water installations where there is DANGER humancontactwithpumpedf...

Page 3: ...eseal sliderailcoupling SRC 6 The moisture cord and or temperature cord is size 18 5 type SO 0 485 for all models 6BSE18034LDS 18 230 3 1750 50 6 232 F 2 3 G 1 34 891 6BSE18044LDS 18 460 3 1750 25 3 1...

Page 4: ...D SIZE CORD TYPE CORD O D WEIGHT pounds 6BSE30034HLDS 30 230 3 1750 76 364 F 2 3 G 1 34 957 6BSE30044HLDS 30 460 3 1750 38 182 F 2 3 G 1 34 957 6BSE36034HLDS 36 230 3 1750 90 434 E 2 3 G 1 34 963 6BSE...

Page 5: ...duplex stations or basins with a slide rail system Barmesa SRC which allows the pump s to be installed or removed without requiring personnel to enter the station or resting on the basin floor 4Discha...

Page 6: ...and phase information stamped on the pump name plate 2 Check Pump Rotation Improper motor rotation can result in poor pump performance and can damage the motor and or pump Check rotation on three pha...

Page 7: ...conduit box 4 to motor housing 3 Apply thread locking compound to cap screws 6 and place into holes and torque to 15 ft lbs Oil Replacement Seal Chamber Refill chamber completely full with new cooling...

Page 8: ...er end bell from motor 1 Remove wave washer Remove upper bearing 2 with a wheel puller if damaged or worn Vertically lift stator 1 from rotor shaft Inspect windings for shorts and resistance Test the...

Page 9: ...s for cap screws 25 Conduit Box Assembly Check power 38 and control cables 39 for crackes or damage and replace complete conduit box 4 if required See Figure 4 Bring motor wires through opening in top...

Page 10: ...lute should be approximately 0 012 inch Service G T1 T7 T2 T8 T3 T9 T4 T5 T6 G L1 L2 L3 GREEN BLACK RED WHITE MOTOR LEADS THREE PHASE 230V AC Cable Motor Lead Number Green Green Black 1 and 7 Red 2 an...

Page 11: ...armesa com MOISTURE SENSOR DETAIL 42 43 40 41 37 34 33 32 31 10 1 STATOR 14 4 46 44 39C 39C 39D 39B 39 10 9 38 38C 38B 38C 38D 8 11 12 7 6 5 3 29 TEMP MOIST WIRES 30 28 WITH MOTOR SUPPLIED WAVE WASHER...

Page 12: ...NC x 2 SS 6 SS 304 13 31020019 Bearing Lower 1 Steel 14 92010051 O Ring 52082 2 Buna Bearing Housing for 18 to 36 HP at 1750 RPM for 9 to 18 HP at 1150 RPM for 48 60 HP at 1750 RPM for 24 to 30 HP at...

Page 13: ...38 31030006 Power Cable 3x2 37917 25 ft 38B 30400904 Hex Head Plug 1 SS 303 38C 30400401 Washer 2 SS 304 38D 92010002 Grommet 1 Rubber 39 31030005 Cord Set Moist temp 5x18 34840 25 ft 39B 30400901 He...

Page 14: ...TH MOTOR SUPPLIED WAVE WASHER 1 ROTOR 13 2 MOISTURE SENSORS SEE DETAIL 18 SEAL MECH 19 20 17 16 14 15 23 24 25 21 22 26 27 41 35 KEYWAY SUPPLIED WITH MOTOR 36 45 NEUTRAL LINES WIRES Figure 7 Repair Pa...

Page 15: ...14 UNC SS 18 SS 304 17 93010131 Hex Head Plug 3 8 SS 22932 1 SS 304 18 93010149 Plug 3 8 1 Cast Iron Mechanical Seal 2130SBH4GS Motor end carbon ceramic buna Pump end silicon silicon buna 20 91010376...

Page 16: ...030006 Power Cable 3x2 37917 25 ft 38B 30400904 Hex Head Plug 1 SS 303 38C 30400401 Washer 2 SS 304 38D 92010002 Grommet 1 Rubber 39 31030005 Cord Set Moist temp 5x18 34840 25 ft 39B 30400901 Hex Head...

Page 17: ...ower supply leads to ensure proper impeller rotation 11 Repair fixturesasrequiredtoeliminateleakage 12 Check pump temperature limits and fluid temperature 13 Replace portion of discharge pipe with fle...

Page 18: ...17 barmesa com...

Reviews: