Before installation, read the following 
instructions  carefully.  Failure  to 
follow 

instruction 

and 

safety 

information  could  cause  serious 
bodily  injury,  death  and/or  property 
damage.  Each  Barmesa  product  is 
carefully  inspected  to  insure  proper 
performance. Closely following these 
instructions  will  eliminate  potential 
operating  problems,  assuring  years 
of trouble-free service. 

IMPORTANT! - Barmesa Pumps is not 
responsible  for  losses,  injury  or 
death  resulting  from  failure  to 
observe  these  safety  precautions, 
misuse,  abuse  or  misapplication  of 
pumps or equipment.

Installation,  wiring,  and 

j u n c t i o n   c o n n e c t i o n s   m u s t   b e   i n 
accordance  with  the  National  Electric 
Code  and  all  applicable  state  and  local 
codes. Requirements may vary depending 
on usage and location.

WARNING

I n s t a l l a t i o n   a n d 

servicing  is  to  be  conducted  by 
qualified personnel only.

WARNING

D o   n o t

  u s e   t h e s e 

pumps  in  water  over  104  °F. 

Do  not

 

exceed  manufactures  recommended 
maximum performance, as this could 
cause the motor to overheat.

WARNING

Ground  Fault  Circuit 

Interrupter  (GFCI)  to  be  used  with 
plug-in type power cord.

WARNING

A L L   R E T U R N E D 
P R O D U C T S   M U S T   B E 
CLEANED,  SANITIZED,  OR

D E CO N TA M I N AT E D   P R I O R   TO 
S H I P M E N T ,   T O   I N S U R E 
E M P L O Y E E S   W I L L   N O T   B E 
EXPOSED TO HEALTH HAZARDS IN 
HANDLING  SAID  MATERIAL.  ALL 
A P P L I C A B L E   L A W S   A N D 
R E G U L AT I O N S   S H A L L   A P P LY .

Keep  clear  of  suction  and 
discharge  openings.  Do  not 
insert  fingers  in  pump  with

power connected; the rotating cutter 
and/or  impeller  can  cause  serious 
injuty.

Always  wear  eye  protection 
when working on pumps. Do 
not wear loose clothing that

may  become  entangled  in  moving 
parts.

Pumps  build  up  heat 
and  pressure  during 
operation.  Allow  time 
f o r   p u m p s   t o   c o o l

DANGER

before  handling  or  servicing  the 
p u m p   o r   a n y   a c c e s s o r y   i t e m s 
associated with or near the pump.

Risk of electric shock. To 

reduce risk of electric shock, 
always  disconnect  pump 
from  power  source  before

DANGER

handling any aspect of the pumping 
system.

 Lock out power & tag.

Do  not

  lift,  carry  or 

hang pump by the electrical 
c a b l e s .   D a m a g e   t o   t h e 
electrical  cables  can  cause

DANGER

shock, burns  or death. 

Never

 handle 

connected  power  cords  with  wet 
hands. Use appropriate lifting device.

Failure  to  permanently 

ground the pump, motor and 
controls  before  connecting 
to  power  can  cause  shock,

DANGER

burns or death.

The  Uniform  Plumbing 

Code  (U P C )  states  that  sewage 
systems shall have an audio and visual 
alarm that signals a malfunction of the 
systems,  that  are  required  to  reduce 
the potencial for property damage.

WARNING

IMPORTANT!  -  Prior  to  installation, 
record  Model  Number,  Serial,  Amps, 
Voltage,  Phase  and  HP  from  pump 
name  plate  for  the  future  reference. 
Also  record  the  Voltage  and  Current 
Readings at Startup:

WARNING

 Indicates  an  immi-

nently hazardous situation which, if 
not avoided, WILL result in death or 
serious injury.

Indicates  an  immi-

nenty hazardous situation which, if 
not avoided, MAY result in death or 
serious injury.

Indicates a potentially 

hazardous  situation  which,  if  not 
avoided,  MAY  result  in  minor  or 
moderate injury.

DANGER

CAUTION

T h i s   p u m p   i s   n o t 

i n t e n d e d   f o r   u s e   i n 
swimming  pools  or  water 
installations  where  there  is

DANGER

human contact with pumped fluid.

These pumps are not to 

be  installed  in  locations 
classified  as  hazardous  in 
accordance with the National

Electric Code, ANSI/NFPA 70.

DANGER

Model  Number:_____________________

Serial:_____________________________

Amps:___________    Volts:____________

Phase:____________  HP:_____________

General Safety Information

barmesa.com

1

Summary of Contents for 2KLEIN-051

Page 1: ...022 Installation Operation Maintenance Manual Submersible Stainless Steel Dewatering Pumps IMPORTANT Read all instructions in this manual before operating or servicing a pump KLEIN series 0 5 1 2 HP 3...

Page 2: ...uild up heat and pressure during operation Allow time for pumps to cool DANGER before handling or servicing the pump or any accessory items associatedwithornearthepump Riskofelectric shock To reduce r...

Page 3: ...dware CORDENTRY 32ftofneoprenecord sealedagainstmoisture BEARINGS Ball singlerow permanentlyoillubricated MOTOR Dry type submersible motor 1 3 phase 115 230 V 60 Hz 3450 RPM Insulation classBandIP68pr...

Page 4: ...1 L W L DN D1 D HP A A1 D D1 DN H H1 H2 0 5 7 4 2 05 4 13 3 35 2 13 58 2 05 1 7 4 2 05 4 13 3 35 2 14 57 2 05 2 8 86 2 05 4 13 3 35 2 17 91 3 19 17 17 Weight without cord Dimensions in inches L W L lo...

Page 5: ...t Productmalfunction Hazard levels NOTICE Savethismanualforfuturereference andkeepitreadilyavailableatthelocationoftheunit Hazard level Indication NOTICE DANGER WARNING CAUTION A hazardous situation w...

Page 6: ...ions Thewarrantydoesnotcoverfaultscausedbythefollowing Deficientmaintenance Improperinstallation Modificationsorchangestotheproductandinstallationcarriedoutwithoutconsultingthemanufacturer Incorrectly...

Page 7: ...propellersortheirretainingdevicestoaidintheirremoval DonotchangetheserviceapplicationwithouttheapprovalofanauthorizedBARMESArepresentative CAUTION You must observe the instructions contained in this...

Page 8: ...restBARMESArepresentative 2 Prior to operation Checkthefollowingpointsuponreceiptofyourpump Is it the pump you ordered Check nameplate It is especially important that you check whether the pump is to...

Page 9: ...lease valve wherever such air pockets are most likely to develop Do not permit end of discharge piping to be submerged as backflow will result when the pump is shut down Non automatic pumps do not hav...

Page 10: ...d as the pump may jerk and cause serious accident involving injury 4 2 Cable 1 Ifthecableisextended donotimmersethespliceinwater 2 Do not pull the cable 3 Install the cable so that it will not overhea...

Page 11: ...Single phase automatic L N PE Black Brown White Blue Green Yellow Green Ground PE Green Yellow Green Yellow Frame grounding Thermal protector Main Auxiliary Capacitor Float switch Figure 4 Three phas...

Page 12: ...blockingtheinletsuction 6 2Regularinspections a Monthlyinspections Measure the insulation resistance The value should be more than 1 megaohm If resistance starts to fall rapidly even withaninitialindi...

Page 13: ...ngorder referringtotheexplodedviewdrawings 1 Removepumpcasingbolts raisethemotorsectionandremovepumpcasing 2 Removeshaftheadboltandimpeller 3 Removeoilfillerpluganddrainlubricatingoil 4 Remove interme...

Page 14: ...E MATERIAL 19 10 SCREW AISI 304 20 WASHER AISI 304 22 SCREW W O RING AISI 304 NBR 23 CABLE SEAT 26 T ADAPTER OPTIONAL 31 NUT AISI 304 31 2 NUT AISI 304 33 SPRING WASHER AISI 304 34 CORRUGATED SPRING S...

Page 15: ...04 10 LIP SEAL NBR 11 IMPELLER AISI 304 ITEM NAME MATERIAL PHOTO 12 PUMP CASING AISI 304 13 PROTECTOR 1 PHASE KLIXON 13 PROTECTOR 3 PHASE KLIXON 14 CAPACITOR 15 1 15 2 BEARINGS 16 STRAINER AISI 304 17...

Page 16: ...AISI 304 ITEM NAME MATERIAL 18 1 GASKET EPDM 18 2 GASKET EPDM 19 SCREW AISI 304 19 1 SCREW AISI 304 19 2 SCREW AISI 304 19 3 SCREW AISI 304 19 4 SCREW AISI 304 19 5 SCREW AISI 304 19 6 SCREW AISI 304...

Page 17: ...SEAL NBR 11 IMPELLER AISI 304 ITEM NAME MATERIAL PHOTO 12 PUMP CASING AISI 304 13 PROTECTOR 1 PHASE KLIXON 13 PROTECTOR 3 PHASE KLIXON 14 CAPACITOR 15 1 15 2 BEARINGS 16 STRAINER AISI 304 17 1 17 2 O...

Page 18: ...2 High liquid temperature has activated motor protector and caused pump to stop 3 Reverse rotation 1 Raise water level to C W L 2 Lower liquid temperature 3 Correct rotation Does not pump Inadequate...

Page 19: ...barmesa com...

Reviews: