background image

15.86"

15.86"

5.12"

5.12"

2"

2"

8.46"

8.46"

2" NPT

2" NPT

3.5"

3.5"

10.82"

10.82"

5.31"

5.31"

2

Specifications & Dimensions

DISCHARGE: 

   

 

2" NPT female, vertical.

SPHERICAL SLD HNDLG: 

 

2"

LIQUID TEMPERATURE:

  

104° F (40° C) max.

VOLUTE:

  

 

 

Cast iron ASTM A-48 class 30.

MOTOR HOUSING:

  

 

Cast iron ASTM A-48 class 30.

SEAL PLATE:

    

 

Cast iron ASTM A-48 class 30.

IMPELLER:

 

 

 

Open, double vane. Cast iron ASTM A-48 class 30, dynamically balanced, ISO G6.3.

SHAFT: 

 

 

 

416 series stainless steel.

HARDWARE:

   

 

300 series stainless steel.

O-RINGS:

 

 

 

Square shaped Buna-N.

PAINT:

  

 

 

Air dry enamel, water based.

SEAL:   

 

 

Single,  mechanical,  oil  filled  chamber.  Silicon  carbide,  Buna-N  elastomer  and 
stainless steel hardware.

CORD ENTRY: 

 

 

20 ft of neoprene cord, sealed against moisture.

UPPER BEARING:

 

 

Ball, single row, oil lubricated, for radial load.

LOWER BEARING:

 

 

Ball, single row, oil lubricated, for radial and thrust load.

MOTOR: 

 

 

NEMA L, single phase, permanent split capacitor, oil filled, with overload protection 
in motor.

MODEL

PART No.

HP

VOLTS PHASE

RPM

(Nominal)

MAX

AMPS

LOCKED

ROTOR AMPS

CORD

SIZE

CORD

TYPE

WEIGHT

(pounds)

2BSE411

62180401

0.4

115

1

1750

12

22.5

14/3

SJTOW

53

2BSE411A

62180402

0.4

115

1

1750

12

22.5

14/3

SJTOW

55

2BSE421

62180403

0.4

230

1

1750

6.1

9.3

14/3

SJTOW

53

2BSE511A

62180404

0.5

115

1

1750

12

22.5

14/3

SJTOW

55

A = Automatic Float Switch.

barmesa.com

Summary of Contents for 2BSE411 Series

Page 1: ...tion Maintenance Manual Submersible Solids Handling Pumps IMPORTANT Read all instructions in this manual before operating or servicing a pump 2BSE411 2BSE511 SERIES 0 4 0 5 HP 1750 RPM Last update 12 03 2020 barmesa com ...

Page 2: ...efore handling or servicing the pump or any accessory items associatedwithornearthepump T h i s p u m p i s n o t i n t e n d e d f o r u s e i n swimming pools or water installations where there is DANGER humancontactwithpumpedfluid Riskofelectric shock To reduce risk of electric shock always disconnect pump from power source before DANGER handling any aspect of the pumping system Lockoutpowerand...

Page 3: ...sed SEAL Single mechanical oil filled chamber Silicon carbide Buna N elastomer and stainlesssteelhardware CORDENTRY 20ftofneoprenecord sealedagainstmoisture UPPERBEARING Ball singlerow oillubricated forradialload LOWERBEARING Ball singlerow oillubricated forradialandthrustload MOTOR NEMA L singlephase permanentsplitcapacitor oilfilled withoverload protection inmotor MODEL PART No HP VOLTS PHASE RP...

Page 4: ...l Discharge Pipe Mounted Level Control Level Control Basic instructions Plug the level control plug into the GFI receptacle then plug the pump into the piggy back plug See Figure 3 One cycle of operation should be observed so that any potential problems can be corrected It is recommended that the level control float should be set to insure that the liquid in the sump never drops below the top of t...

Page 5: ...n damage the motor and or pump Incorrect rotation for Single Phase pumps is unlikely If the rotation is incorrect contact factory 3 Name Plate Record the information from the pump name plate to drawing in front of manual for future reference 4 Insulation Test An insulation megger test should be performed on the motor Before the pump is put into service The resistance values ohms as well as the vol...

Page 6: ...age and replace if required To remove impeller place a flat screwdriver in the slot of the end of the shaft to hold the shaft stationary while unscrewing the impeller 5 Check v ring and remove if damaged Power Cord and Motor 6 Remove pipe plug and drain oil from housing 7 Remove gland nut washer and ring from housing Pull cord through and disconnect the wires from the terminals on power cord 8 Rem...

Page 7: ...apped surface of rotating member facing outward slide over shaft using a seal tool being carefull not to damage seal face Make sure spring is seated in retaining ring and spring is lined up on rotating member and not cocked or resting on bellows tail Motor 5 Slide rotor shaft with bearings and seal parts into seal plate until bearing seats into seal plate Install snap ring into seal plate 6 Place ...

Page 8: ...7 Repair Parts For Repair Part Please supply Model Number and Serial as shown on Name Plate and Part Description and Part Number as shown on Parts List barmesa com ...

Page 9: ...ER Ø138 2 1 HT200 16 CASING 1 HT200 17 CASING SEALING WASHER 1 RUBBER 18 HEX SOCKET CAP SCREW 1 4 20UNC x 28 2 SS 304 19 V SHAPE RING 1 NBR40 20 MECHANICAL SEAL 1 2 Ø25 4 1 SiC SiC 21 ELASTIC COLLAR 40 1 65Mn 22 BEARING 6203 1 23 LENGTHERN BOLT 8 32 x 125 4 Q235A 24 FLATWASHER 4 4 Q235A 25 SPRING WASHER 4 4 65Mn 26 LOWER BEARING PLATE O RING 1 NBR40 27 CAPACITOR CLAMP 1 08F 28 CROSS RECESS PAN HEA...

Page 10: ...wer supply leads to ensure proper impeller rotation 11 Repair fixturesasrequiredtoeliminateleakage 12 Check pump temperature limits and fluid temperature 13 Replace portion of discharge pipe with flexible connector or tighten existing piping 14 Turn to automatic position 15 Check for leaks around basin inlet and outlets Pump will not turn off 2a Float movement restricted 2b Switch will not activat...

Page 11: ......

Reviews: