Manual 2100-587C
Page
54 of 59
WG3S2-B, WG4S2-B, WG5S2-B 208/230/60/3
T2
NC
C
L2 L3
Au
x.
L1
T1
T3
PINK
PI
NK
L1
BLUE
BLUE
5
4
3
GR
BLUE
BLUE
1 2 3
4 5 6
8 9
7
12
10 11
BLUE
BLUE
L2
BLUE
PURPLE
PURPLE
PURPLE
C
MV
NO
MV
YELLOW
ORANGE
YELLOW
YELLOW/BLACK
YELLOW
YE
LL
OW
/B
LA
CK
BR
OW
N/
W
HI
TE
YE
LL
OW
/R
ED
YELLOW
YELLOW
YELLOW
YELLOW
YELLOW
RED/WHITE
WHITE
RED
RED
RE
D
RE
D
RE
D/
W
HI
TE
RED
RED
RED
RED
RED
RE
D
RED/WHITE
53
RED
RE
D/
W
HI
TE
RE
D
49
49
45
43
RED/
RED
FOR INDOOR
BLACK
PIN PLUG
BLACK
(OPT.)
BL
AC
K/
W
HT
IE
16 PIN PLUG FOR
INDOOR BLOWER
MOTOR
BLACK/WHITE
SOLENOID
BLACK/WHTIE
BLOWER MOTOR
SPEED
15
0
13
5
12
0
FUSE
13
2
6
10
1
3
15
12
14
BL
AC
K/
W
HI
TE
208/230-60-3
BL
AC
K
BL
AC
K
BLACK
P3
BLACK/WHITE
BROWN
1
PL
1
2
BR
GRAY
BLACK/WHITE
BLACK
BR
OW
N
BL
AC
K/
W
HI
TE
BLACK
BLACK
BROWN
BL
AC
K/
W
HI
TE
BL
AC
K
BLACK/WHITE
27
TERM. BLOCK
GR
AY
L3
YELLOW
ROLLOUT
SPARK IGNITOR
Optional
30
INDUCED
DRAFT BLOWER
CO
M
PR
ES
SO
R
CO
NT
AC
TO
R
51
GAS
VALVE
20
32
52
37
35
35
40
40
35
35
32
47
T2
32
32
32
32
34
32
32
62
28
28
28
37
28
27
27
42
44
41
38
36
47
41
33
28
28
28
FLAME
LIMIT
32
38
PRIMARY
FLAME SENSOR
39
PRESSURE
SWITCH
32
32
28
35
38
51
51
51
46
46
46
T3
48
T1
Field
Factory
High Voltage
Low Voltage
52
32
15
32
60
60
32
A
32
A
LOW AMBIENT
CONTROL (OPT.)
62
47
A
WIRES CONNECT
IF OPTION
NOT USED
31
29
4085-255 A
LOW
MOTOR
LP
C
VOLTAGE
WHICH IS 250°C HIGH VOLTAGE CABLE
TEMPERATURE RATING OF AT LEAST 105° C EXCEPT THE IGNITION CABLE
OUTDOOR
FAN
INTEGRATED FURNACE CONTROL 13
R
LP
C
5
3
2
4
M
IN
UTE
S
STRIP
11
28
CIRCUIT BREAKER
21
MOVE RED WIRE TO
208V TAP FOR 208V
OPERATION
TRANSFORMER
18
GROUND TERMINAL
25
PH
AS
E
M
ON
IT
OR
CAPACITOR
19
LOW
PRESSURE
SWITCH
INDUCED DRAFT
BLOWER RELAY
MODULE
5
4
2
1
3
240V
208V
COM
R
CONTROL
23
HEATER
C
HIGH
PRESSURE
SWITCH
CRANKCASE
HIGH SPEED
16
C
COMPRESSOR
50
Compressor
CC
HP
C
Y
AL
R
IF ANY ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE
REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A
USE COPPER CONDUCTORS
SUITABLE FOR AT LEAST 75° C
1
Model C. Breaker Capacitor
WG3S2-B
30A
10/370
WG4S2-B
40A
10/370
WG5S2-B
40A
10/370
Summary of Contents for WG3S2-A
Page 11: ...Manual 2100 587C Page 11 of 59 FIGURE 2A MOUNTING INSTRUCTIONS FOR WG3S2...
Page 12: ...Manual 2100 587C Page 12 of 59 FIGURE 2B MOUNTING INSTRUCTIONS FOR WG4S2 AND WG5S2...
Page 15: ...Manual 2100 587C Page 15 of 59 FIGURE 6 COMMON WALL MOUNTING INSTALLATIONS...
Page 25: ...Manual 2100 587C Page 25 of 59 FIGURE 11 GAS PIPE CONNECTION...