Manual 2100-646
Page
22 of 26
Motor will deliver consistent CFM through voltage supply range with no deterioration.
(197-253V for 230/208V models, 414-506V for 460V models)
Continuous CFM is the total air being circulated during continuous (manual) fan mode.
Will occur automatically with a call for "Y1" signal from thermostat.
Will occur automatically with a call for "Y2" signal from thermostat.
Will occur automatically with a call for "W1" signal from thermostat.
Will occur automatically with a call for "W2" or "Emergency Heat" signal from thermostat.
TABLE 7
Indoor Blower Performance
TABLE 8
Optional Accessories – Right Hand Units
Model
Rated ESP
Max ESP
Continuous
CFM
Rated 1st
Stage CFM
Rated 2nd
Stage CFM
5-10 KW
CFM
15-20 KW
CFM
HA/L4S4
0.20
0.80
825
1100
1500
1100
1500
HA/L5S4
0.20
0.80
850
1300
1700
1100
1500
HA4S4KA
HA5S4KA
Model
EHWA4S-A05
Heater Package
X
EHWA4S-A10
Heater Package
X
EHWA4S-A15
Heater Package
X
EHWA5S-A05
Heater Package
X
EHWA5S-A08
Heater Package
X
X
EHWA5S-A10
Heater Package
X
EHWA5S-A15
Heater Package
X
BOP-5
Blank Off Plate (Standard)
X
X
TABLE 9
Optional Accessories – Left Hand Units
HL4S4KA
HL5S4KA
Model
EHWA4S-A05L
Heater Package
X
EHWA4S-A10L
Heater Package
X
EHWA4S-A15L
Heater Package
X
EHWA5S-A05L
Heater Package
X
EHWA5S-A10L
Heater Package
X
EHWA5S-A15L
Heater Package
X
BOP-5
Blank Off Plate (Standard)
X
X