OIL LINE PIPING
First determine whether the pipe system is to be a single
line system or a two line system. All connections must
be absolutely air tight or you will have a malfunction of
the burner. When installing the piping, a good oil filter
should be installed close to the burner. A single line
system is recommended for gravity feed.
A typical single inside tank installations shown in
Figure 5. For installation details for this and other tank
configurations, refer to NFPA31 -- latest edition. All
tank and pipe setups must comply with NFPA31.
BECKETT AFG OIL BURNER
This furnace is equipped with a high static Beckett AFG
oil burner which is designed to produce adequate draft
in nearly any vertically vented application. The burner
employs the latest time tested controls of the highest
quality. The controls consist of a high voltage Beckett
solid state igniter, a Beckett “CleanCut” oil pump with
an integral solenoid valve, and a Beckett R7184B
primary control.
These controls were selected for their proven high
quality, dependability, and serviceability. With proper
maintenance this burner assembly will provide many
years of reliable service.
All units are shipped with the oil burner installed, and
with high rate oil nozzle installed designed for use with
No. 1 or No. 2 fuel oil. Inspect firepot refractory
before firing to be sure it has not been jarred out of
position in shipment. Burner air tube must not
extend beyond inside surface of firepot. Burner
head should be centered on the combustion chamber
opening. See Figures 16A and 16B.
FIGURE 5
TYPICAL SINGLE INSIDE TANK INSTALLATION
WARNING
Never attempt to use gasoline in your furnace.
Gasoline is more combustible than fuel oil and
could result in a serious explosion causing
damage, injury or death.
MIS-1340