Required tools
•
Torx screwdriver T20
•
Flat screwdriver
•
Open-end wrench 24 mm
•
Nut driver 10 mm
•
Torque wrench with 10 mm hexagon socket
Required parts
Certified AC power supply cord 1.5 mm², 14 AWG, min 300 V
How to connect a UPS unit with the projector electronics?
1.
Make sure the net input cover has been removed. For more info, see
“Accessing the power connections”,
.
2.
Loosen the top nuts on the six UPS configuration pins. Use a 10 mm nut driver.
Image 4–8
3.
Replace the links as illustrated.
Image 4–9
4.
Guide the AC power cord (reference 2) through the cable gland (reference 3). Connect the wires
(references 4 and 5) to the 3-terminal strip as illustrated. Use a torque screwdriver to fasten the screws of
the 3-terminal strip with a torque of
0.75 Nm
.
Warning:
Always connect the PE wire (reference 4) first, then the other wires.