1. Safety

1. SAFETY

1.1 Safety

Safety Warnings

The procedures in this manual are intended for use only by qualified service technicians who have been trained and authorized by
BARCO !

Switch the projector to stand by and let it cool down for at least 15 minutes before starting with the lamp replacement. These lamps
consist of a quartz arc tube operating at very high temperature and high pressure which may explode suddenly. There is a risk of
personal injury and property damage from hot quartz arc tube particles if handled incorrectly.

Power down the projector and unplug the power cord from the wall outlet. Once the projector is cooled down and the power is off,
continue with the replacement procedure.

Do not exceed the indicated maximum total lifetime of the lamp for safe operation in normal power mode. Do not use it longer !
Always replace the lamp with the BARCO lamp kit for 6500 projectors.

R5976452 UNIVERSAL LAMP KIT FOR 6000 SERIES LCD PROJECTORS 15032002

1

Summary of Contents for R9841550

Page 1: ...BARCO PROJECTION UNIVERSAL LAMP KIT FOR 6000 SERIES LCD PROJECTORS R9841550 INSTALLATION MANUAL 15032002 R5976452 01...

Page 2: ...Barco nv Intelligent Displays Noordlaan 5 8520 Kuurne Phone 32 56 36 82 11 Fax 32 56 35 86 51 E mail presentations bid barco com Visit us at the web www barco com Printed in Belgium...

Page 3: ...t names mentioned in this manual serve as comments or examples and are not to be understood as advertising for the products or their manufactures Copyright All rights reserved No part of this document...

Page 4: ......

Page 5: ...uurne Phone 32 56 36 82 11 Fax 32 56 35 86 51 E mail presentations bid barco com Web www barco com From Date Please correct the following points in this documentation R5976452 01 page wrong correct R5...

Page 6: ......

Page 7: ...igh pressure which may explode suddenly There is a risk of personal injury and property damage from hot quartz arc tube particles if handled incorrectly Power down the projector and unplug the power c...

Page 8: ...1 Safety 2 R5976452 UNIVERSAL LAMP KIT FOR 6000 SERIES LCD PROJECTORS 15032002...

Page 9: ...t is designed for the 6500 R G 6400i and SIM6 HB projectors 2 2 Partslist of the Kit Partslist overview Depending on the Kit ordered R9841550 single lamp R98415501 12 pack R98415502 60 pack following...

Page 10: ...2 Kit content 2 3 Illustration of the Lamp Universal lamp Image 2 1 4 R5976452 UNIVERSAL LAMP KIT FOR 6000 SERIES LCD PROJECTORS 15032002...

Page 11: ...sure that the projector is turned off Never open the lamp house when the projector is on Necessary tools flat screwdriver of 5 mm How to remove the lamp door 1 Turn with a screwdriver the door lock s...

Page 12: ...image 3 3 2 Pivote the plate a little downwards image 3 4 3 Take out the protection cover Image 3 3 Image 3 4 Hot surface Do not touch the fan blades High pressure lamp may explode if improperly hand...

Page 13: ...between thumb and finger 4 Unlock the connector by pushing at the same time on both lock parts and separate the connectors image 4 3 Image 4 1 Image 4 2 Image 4 3 The length of the lamp power cables m...

Page 14: ...4 Removing the old lamp unit 8 R5976452 UNIVERSAL LAMP KIT FOR 6000 SERIES LCD PROJECTORS 15032002...

Page 15: ...ry tools flat screwdriver 5mm Phillips screwdriver 3mm Adjusting the lamp 1 Place the metallic plate as shown on the figures depending on the mounting configuration image 5 1 image 5 2 To place the la...

Page 16: ...n the housing as shown on the image 2 Connect the connector at the lamp side into the connector at the power side image 5 6 3 Slide the lamp unit in the lamp house until the ref holes in the bottom pa...

Page 17: ...5 Installing the lamp unit Image 5 7 A reference holes R5976452 UNIVERSAL LAMP KIT FOR 6000 SERIES LCD PROJECTORS 15032002 11...

Page 18: ...5 Installing the lamp unit 12 R5976452 UNIVERSAL LAMP KIT FOR 6000 SERIES LCD PROJECTORS 15032002...

Page 19: ...he lamp power cable Do not stick this cable between the protection cover and the lamp house 2 Secure the position of the cover with the 3 indicated bolts image 6 2 Image 6 1 Image 6 2 Closing the lamp...

Page 20: ...6 Closing the lamp house Image 6 3 Image 6 4 14 R5976452 UNIVERSAL LAMP KIT FOR 6000 SERIES LCD PROJECTORS 15032002...

Page 21: ...to continue ADJUSTMENT MODE Select a path from below AUTO IMAGE RANDOM ACCESS INSTALLATION SERVICE Source 01 Select with or then ENTER EXIT to return Menu 7 1 SERVICE IDENTIFICATION CHANGE PASSWORD C...

Page 22: ...7 Additional operations Image 7 1 Image 7 2 16 R5976452 UNIVERSAL LAMP KIT FOR 6000 SERIES LCD PROJECTORS 15032002...

Page 23: ...ing the dust filters 15 I Installing 9 lamp 9 K Kit 3 4 content 3 Illustration 4 partslist 3 purpose 3 L Lamp 5 9 access 5 installing 9 Lamp run time 15 reset 15 Lamp unit 7 13 closing 13 extracting 7...