background image

A-1

Appendix A : Standard Source Set Up Files

R5976262 BARCO SLM G5 Executive 13072001

A

STANDARD SOURCE SET UP FILES

NAME :

 NAME OF FILE, CONTAINS THE

SETTINGS

RESOLUTION : IMAGE RESOLUTION, WHEN

FOLLOWED BY ...I MEANS INTERLACED.

FVERT HZ :

 VERTICAL FRAME FRE-

QUENCY OF THE SOURCE

FHOR KHZ :

 HORIZONTAL FREQUENCY

OF THE SOURCE.

FPIX MHZ :

 PIXEL FREQUENCY

PTOT :

 TOTAL PIXELS ON ONE HORIZON-

TAL LINE

PACT :

 ACTIVE PIXELS ON ONE HORI-

ZONTAL LINE

LTOT :

  TOTAL LINES IN ONE FIELD

LACT :

 ACTIVE LINES IN ONE FIELD

NAME

RESOLUTION FVERT FHOR FPIX

PTOT PACT

LTOT LACT

HZ

KHZ

MHZ

1600_48V

1600 X 600I

48,040 62,500 135,000 2160 1600

651

600

1600_60V

1600 X 1200

60,000 75,000 162,000 2160 1600

1250 1200

1600_65V

1600 X 1200

65,000 81,250 175,500 2160 1600

1250 1200

1600_70V

1600 X 1200

70,000 87,500 189,000 2160 1600

1250 1200

8514_A

1024 X 384I

43,479 35,522 44,900 1264 1024

409

384

CGA

640 X 200

59,924 15,700 14,318 912

640

262

200

COMPUSC4

1024 X 480I

29,945 30,694 39,779 1296 1024

512

480

ED

735 X 480

59,943 31,470 28,638 910

735

525

480

EGA

640 X 350

59,702 21,851 16,257 744

640

366

350

EWS_50

1280 X 1024

50,000 52,350 87,948 1680 1280

1047 1024

EWS_60

1280 X 1024

60,000 63,900 107,352 1680 1280

1065 1024

EWS_60V

1280 X 1024

60,282 63,657 110,000 1728 1280

1056 1024

EWS_72

1280 X 1024

72,000 76,968 130,076 1690 1280

1069 1024

EWS_75

1280 X 1024

75,025 79,976 135,000 1688 1280

1066 1024

FMR

640 X 400I

42,323 36,440 28,570 784

640

431

400

FMTO_2

640 X 400

55,370 24,370 21,056 864

640

440

400

HD_24P

1920 X 1080

24,000 27,000 74,250 2750 1920

1125 1080

HD_25I

1920 X 540I

25,000 28,125 74,250 2640 1920

563

540

HD_25P

1920 X 1080

25,000 28,125 74,250 2640 1920

1125 1080

HD_30I

1920 X 540I

30,000 33,750 74,250 2200 1920

563

540

HD_30I_2

1920 X 517I

30,000 33,750 74,250 2200 1920

563

517

HD_30P

1920 X 1080

30,000 33,750 74,250 2200 1920

1125 1080

HD_60P

1920 X 720

60,000 45,000 74,250 1650 1280

750

720

HDMAC

1648 X 570I

25,020 31,250 39,125 2047 1648

625

570

INTER_GR

1184 X 886

67,170 61,796 92,941 1504 1184

920

886

MAC_2

640 X 480

66,667 35,000 30,240 864

640

525

480

MAC_3

512 X 384

60,147 24,480 15,667 640

512

407

384

MAC_4

560 X 384

60,147 24,480 17,234 704

560

407

384

MAC_5

512 X 342

60,158 22,259 15,670 704

512

370

342

MAC_6

832 X 624

74,546 49,722 57,280 1152 832

667

624

MAC_7

1024 X 768

74,907 60,150 80,000 1330 1024

803

768

MAC_LC

640 X 480

66,619 34,975 31,338 896

640

525

480

All manuals and user guides at all-guides.com

Summary of Contents for R9002780

Page 1: ...BARCO PROJECTION SYSTEMS Date 13 07 2001 OWNER S MANUAL Rev 00 R9002780 Art No R5976262 SLM G5 Executive All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 2: ...june 2001 All rights reserved Trademarks are the rights of their respective owners BARCOn v ProjectionSystems Noordlaan5 B 8520Kuurne Belgium Tel 32 56 368211 Fax 32 56 351651 E mail sales bps barco...

Page 3: ...Humidity Conditions 3 1 Environment 3 1 Environment condition check 3 1 Special care for Laser beams 3 1 Which screen type 3 1 What image size How big should the image be 3 2 Projector Configurations...

Page 4: ...5 3 Lamp Run Time Indication 5 3 Lamp Run Time Warning 5 3 Lamp Light Output Indication 5 4 Switching to Stand by 5 4 Switching Off 5 4 Temperature error DMD 5 4 Quick Set Up Adjustments 5 4 Quick La...

Page 5: ...usted 7 9 CTI ON OFF 7 9 What is CTI 7 9 How to change the CTI setting 7 9 Note 7 9 ColorTemperature 7 10 Start Up 7 10 Available color temperature 7 10 Adjusting the Color Temperature 7 10 Custom Bal...

Page 6: ...8 4 What can be done 8 4 Set up the Correct Configuration 8 4 OSD color On Screen Display 8 4 What can be done 8 4 How to change this color setting 8 4 No Signal 8 5 What will happen 8 5 Changing the...

Page 7: ...ch information is available 9 7 How to switch the constant light output 9 7 BARCO logo 9 7 What can be done 9 7 How to add or the change the settings 9 7 Available settings 9 8 Add Ins 9 8 How to get...

Page 8: ...i 6 R5976262 BARCO SLM G5 Executive 13072001 All manuals and user guides at all guides com...

Page 9: ...requirements it should always be operated with all of it s covers in place Ensure that nothing can be spilled on or dropped inside the projector If this does happen switch off and unplug the mains sup...

Page 10: ...s Persons having appropiate technical training and experience necessary to be aware of hazards to which they are exposed in performing a task and of measures to minimize the danger to themselves or ot...

Page 11: ...lette turn out the 8 retaining bolts Use a 13 mm wrench to remove these bolts Take the projector out of its shipping carton by handling by the carry handle and place it on the floor or table Warning D...

Page 12: ...l item They are packed in a carton Projector Case Dimensions The dimensions are given in mm 25 4 mm 1 Q R P L Q D O 5 287 5217 9 5 UHFHLYHU 3RLQW RI JUDYLW 5 287 0DLQV SRZHU 3RZHU 6ZLWF K RFDO NH SD G...

Page 13: ...s optics as these will degrade optical coatings and damage sensitive optoelectronic components Failure to take suitable precautions to protect the projector from the effects of persistant and prolonge...

Page 14: ...he weight of the projector 46 5 kg without projection lens To carry the projector by the carry handler 2 persons are needed The mounting position shown in the above images are shown for a nominal lens...

Page 15: ...HQ 3 ORRU 3UR MHFWRU 6 2 S WLFDO D LV S URMHFWLR Q OHQV 6 6 6 9 9 6FUHHQ 52 17 9 6 ORRU 7 DE OH V WD QG LQJ 6 3 R LQ W R I J U D Y LW 6FUHHQ 3 HLOLQJ 3URMHFWRU 6 2SWLFDO D LV SURMHFWLRQ OHQV 6 6 6 9...

Page 16: ...ice 4 Select Lamp The Z axis indication lamp menu in service mode will be helpful while turning screw B image 7 5 Loosen the nut A image 7 on the back of the lamp casing nutdriver 10 6 Adjust the scre...

Page 17: ...1 R9840900 TLD 5 0 8 0 1 R9840910 Lensformulastocalculatetheprojectordistance For TLD lenses Metric formulas meter Inch formulas inch TLD 0 8 1 PD 0 85 x SW 0 05 PD 0 85 x SW 1 97 TLD 1 2 1 PD 1 22 x...

Page 18: ...ps on both sides 2 Move the handle A of the lens anchor system to the right image 8 3 Push the lens motors at the top in the lens block gap horizontally lining up the motor connector on the lens with...

Page 19: ...bric softener when washing the cleaning cloth or softener sheets when drying the cloth 6 Do not use liquid cleaners on the cloth as doing so will contaminate the cloth Order number for a new TorayseeT...

Page 20: ...power switch the projector starts in the stand by mode The projector mode indication lamp is red To start image projection a press the Stand by button A on the local keypad or on the remote control Th...

Page 21: ...inutes Press EXIT to remove the message before the minute is over When the total run time of the lamp is 1500 hours or more the following warning message with the exact run time is displayed on the sc...

Page 22: ...not used When using a RCVDS05 it is recommended to use a 5 cable output module in the RCVDS The outputs of this module has to be connected to slot 1 of the projector To switch the projector in the 5...

Page 23: ...andles of the input module until the module plug seats in the connector of the projector 5 Secure the input module by tightening both retaining screws 6 Reconnect the power cord to the wall outlet and...

Page 24: ...r Pin1 TMDS DATA2 Pin9 TMDS DATA1 Pin 17 TMDS DATA0 Pin2 TMDSDATA2 Pin 10 TMDSDATA1 Pin 18 TMDSDATA0 Pin3 TMDS DATA2 4 Shield Pin 11 TMDS DATA1 3 Shield Pin 19 TMDS DATA0 5 Shield Pin4 TMDS DATA4 Pin...

Page 25: ...sync or composite tri level sync COMPONENT VIDEO SOY SOY or 3LSOY component video with composite sync on Y or composite tri level sync on Y VIDEO S VIDEO PANELLINK When changing from an analog signal...

Page 26: ...s full compatibility with digital Betacam or other digital video sources This avoids the need for analog video processing anywhere in the video production chain and guarantees the ultimate image quali...

Page 27: ...or short distances up to 10 m you can use a single shielded high quality 75 ohm coax cable For longer distances you need to use a double shielded 75 ohm coax cable Recommended type Belden 8281 up to 8...

Page 28: ...via the expansion module Serial communication with the projector Remote control buttons on the RCVDS to control the projector source selection and analog settings The selected source number will be di...

Page 29: ...4 10 Connections R5976262 BARCO SLM G5 Executive 13072001 All manuals and user guides at all guides com...

Page 30: ...or source selection control adaptation and set up It includes automatic storing of picture controls Brightness Sharpness settings Other functions of the control units are switching between standby and...

Page 31: ...can be removed by pressing TEXT key first To re display the bar scale on the screen press TEXT key again When TEXT is off no adjustment menu s will be displayed on the screen when entering the adjust...

Page 32: ...isplayed for 1 minute This warning message will be repeated every 30 minutes Press EXIT to remove the message before the minute is over When the total run time of the lamp is 1500 hours or more the fo...

Page 33: ...e fans stopblowing or at least 15 min Switch off the projector with the power switch TemperatureerrorDMD When the temperature of one of the DMD is too low or too high the projector will be switched au...

Page 34: ...layed 2 Push the cursor key or to zoom and and to focus the image 3 When finished press EXIT key to return or ENTER to continue to the shift adjustment Other adjustment patterns are possible by pushin...

Page 35: ...to display Installation menu 4 Push the cursor key or to highlight OSD Color 5 Press ENTER to display the OSD color menu 6 Push the cursor key or to highlight the desired color 7 Press ENTER to select...

Page 36: ...or labelled Hardwired CTRL2 2 8 7 1 2 Q 5 6 7 0 2 8 2 8 7 1 2 Q 6 7 1 387 2 00 3257 75 5 287 56 287 56 1 5 5HF HLYHU LDJQRVWLF RGH UHHQ 2SHUDW L RQ 5HG 6WDQ G E 5 6 QF 2 DUGZL UHG UHPRWH 75 DUGZLUHG U...

Page 37: ...RCU Before using the RCU its is necessary to enter the projector address into the RCU only when that address is between 0 and 9 The projector with the corresponding address will listen to that specifi...

Page 38: ...control e g brightness appears on the screen only if text is ON See example screen The length of the bar scale and the value of the numeric indication indicate the current memorized setting for this...

Page 39: ...ey is pressed the image projection is stopped a blue or black screen will be displayed and the projector remains with full power for immediate restart To restart the image 1 press pause key 2 press ex...

Page 40: ...sword language address etc or some service actions as reset lamp run time panel adjustments etc or get set up information PasswordProtection A 3 level password protection is built in Different passwor...

Page 41: ...nter password menu returns on the screen Remark When re entering the Adjustment mode it will be nessary to enter the password again when selecting a password protected item SettingUpthepersonalisedPas...

Page 42: ...ENTER ADJUSTMENT MODE Select a path from below RANDOM ACCESS INSTALLATION SERVICE Source 01 Select with or then ENTER EXIT to return OverviewFlowchart RANDOMACCESS ADJUSTMENTMODE LOAD EDIT RENAME COP...

Page 43: ...turns to the Path selection menu ADJUST returns to operational mode PossibleFileManipulations The following file manipulations are possible Load installation of a file for a new source Edit editing a...

Page 44: ...will be displayed menu 2 with the newly created file and the one on which the new file is based on 3 Press ENTER to confirm the new creation or EXIT to return to the load file menu During a load file...

Page 45: ...675x240i Active file Video525 c50 Select with or ENTER to accept EXIT to return menu1 menu2 Which items can be adjusted Total quantity horizontal pixels Active quantity horizontal pixels Horizontal st...

Page 46: ...e when active file see caution above The Vertical Total Lines are already filled when an active file is selected to be edited see caution above The Active Lines number of horizontal lines determining...

Page 47: ...all other sources below 60 Hz asynchronous mode is default 2 For sources with a vertical frequency higher that 60 Hz the vertical refresh is different than the vertical frequency of the incoming sour...

Page 48: ...s highlighted COPY FILE Filename Src Resolution Video525 s01 1 675x240i Video525 c01 1 675x240i Video525 c02 1 675x240i Active file Video525 c50 Select with or then ENTER EXIT to return FILE SERVICE L...

Page 49: ...press ENTER If you do not want to delete the file press EXIT Note the active file cannot be deleted menu1 menu2 menu3 File Options StartUp 1 Push the cursor key or to highlight File Options menu 1 2 P...

Page 50: ...GAMMA DECODING EBU DYNAMIC COLOR DEPTH NOISE REDUCTION INPUT BALANCE Select with or then ENTER EXIT to return Select with or then ENTER EXIT to return RANDOM ACCESS ADJUSTMENT MODE FILE SERVICE PICTU...

Page 51: ...ill provide maximum projector light output The calibrated Broadcast Film Video and Computer presets will provide optimum color tracking Custom balance allows the user to set his own prefered color tem...

Page 52: ...enish tint How can it be selected 1 Push the cursor key or to highlight Decoding 2 Press ENTER to toggle between EBU or IRE 3 Press EXIT to return Select with or then ENTER EXIT to return menu1 menu3...

Page 53: ...white areas e g image 1 ATTENTION there are 2 different adjustment procedures one for RGB included Video and S Video and ane for YUV input signals How to adjust the input balance for RGB Video and S...

Page 54: ...stment in such a way the blue and red noise are just visible and a small Brightness increase maintain a grey colour Checking the White Balance There is no adjustment procedure for the White Balance Th...

Page 55: ...s negative the image is shifted to the left Example for table mount configuration RUL RQWDO VL H DGMXVWPHQW 9HUWLFDO VL H DGMXVWPHQW L HG VLGHV menu1 Select with or then ENTER EXIT to return GEOMETRY...

Page 56: ...ENTER to display the blanking menu 3 Push the cursor key or to highlight desired blanking menu 2 4 Press ENTER to start up the chosen blanking 5 Use the cursor keys to adjust the blanking BLANKING TO...

Page 57: ...typical aspect ratio E g projecting a 4 3 image in a 16 9 format Setting Up the Aspect Ratio 1 Push the cursor key or to highlight Aspect Ratio menu 1 2 Press ENTER to to toggle between 4 3 16 9 5 4...

Page 58: ...gnal to display a black or blue screen when no source is connected to the projector or to set up the auto shutdown Internal Patterns Lens adjustment Overview of the Quick Access Keys Menu Position def...

Page 59: ...or VS05 connected or RCVDS is switched off When a 800 peripheral is connected to the projector the input slots are not accessible with the cursor keys to toggle their function 800 Peripheral What can...

Page 60: ...L PATTERNS NO SIGNAL LENS QUICK ACCESS KEYS MENU POSITION DEFAULT menu 1 Convergence What can be done The convergence of the displayed image can be adjusted only by a qualified service technician How...

Page 61: ...front ceiling rear ceiling rear table Set up the Correct Configuration 1 Push the cursor key or to highlight Configuration menu 1 2 Press ENTER to select 3 Push the cursor key or to highlight the desi...

Page 62: ...ere is no signal connect to the projector the background color can be black or blue and the projector can shutdown after a certain time INSTALLATION INPUT SLOTS 800 PERIPHERAL CONVERGENCE CONFIGURATIO...

Page 63: ...ne with these internal patterns The projector is equipped with different internal patterns which can be used for measurment and alignment purposes How to select an internal pattern 1 Push the cursor k...

Page 64: ...2 How to shift the image 1 When on the Zoom Focus menu menu 1 press ENTER to switch to the shift menu or 2 When on the Lens Adjustment menu menu 2 push the cursor key or to select Shift and press ENTE...

Page 65: ...ALL menu 1 Select with or then ENTER EXIT to return LENS ADJUSTMENT ZOOM FOCUS SHIFT OPTIONS LENS Options The zoom focus and shift can be set the same for all files 1 Push the cursor key or to highlig...

Page 66: ...NTER to toggle between DEFAULT and CENTER DEFAULT menus displayed in the center adjustment boxes displayed in the corner CENTER menus and adjustment boxes displayed in the center of the image menu 1 S...

Page 67: ...8 10 Installation Mode R5976262 BARCO SLM G5 Executive 13072001 All manuals and user guides at all guides com...

Page 68: ...INPUT BALANCE DIAGNOSIS MORE Select with or then ENTER EXIT to return CHANGE PROJ ADDRESS Enter new address 001 Select with or Reprogram with or or numeric keys ENTER to confirm EXIT to return Select...

Page 69: ...r address software version installation configuration baud rate text ON projector serial number projector run time Detaileddescription type of projector BARCO SLM R6 software version Proj Address to c...

Page 70: ...proceed as follows 1 Power down the projector and disconnect the power cord from the wall outlet 2 Loosen the indicate screws of the input box image 1 3 Pull out the input box by both handlers 4 When...

Page 71: ...hlight Change password menu 1 2 Press ENTER to display the Change password menu menu 2 Only possible when owner 3 Push the cursor key or to highlight Access Control List menu 2 4 Press ENTER to displa...

Page 72: ...menu1 menu2 Select with or then ENTER EXIT to return SERVICE IDENTIFICATION CHANGE PASSWORD CHANGE LANGUAGE CHANGE PROJ ADDRESS SERIAL COMMUNICATION LAMP MORE Enteringthenewprojectoraddress 1 the dig...

Page 73: ...andle as follow 1 Push the cursor key or to highlight Interface Standard menu 1 The actual interface standard will be displayed 2 Press ENTER to toggle between RS232 and RS422 Default RS232 Select wit...

Page 74: ...the lamp must be replaced Using the lamp longer than the maximum run time 1500 hours may damage the projector Number of strikes Total times the lamp is started up Z AXIS indication to adjust the Z AX...

Page 75: ...number of your projector Available Add Ins CLO When activated the lamp option Constant light output in the menu Lamp becomes available How to activate an add in 1 Push the cursor key or to highlight A...

Page 76: ...Balance is selected in the Service Mode selection menu the following warning will be displayed Preset Input Balance is reserved to qualified service personnel If you are not qualified press EXIT to ca...

Page 77: ...ndication behind the hex code is green everything is ok If the indication is red something is wrong with that indicated address Select with or then ENTER EXIT to return menu1 DIAGNOSIS I2C FORMATTER F...

Page 78: ...d A function key can only be programmed when in the adjustment mode Handle as follow 1 Scroll through the menus until the desired menu is reached 2 Press the desired function key for this menu during...

Page 79: ...ProgrammableFunctionKeys 10 2 R5976262 BARCO SLM G5 Executive 13072001 All manuals and user guides at all guides com...

Page 80: ...EWS_60 1280 X 1024 60 000 63 900 107 352 1680 1280 1065 1024 EWS_60V 1280 X 1024 60 282 63 657 110 000 1728 1280 1056 1024 EWS_72 1280 X 1024 72 000 76 968 130 076 1690 1280 1069 1024 EWS_75 1280 X 1...

Page 81: ...SUNEWS76 1280 X 1024 76 107 81 130 135 000 1664 1280 1066 1024 SUNXGA60 1024 X 768 59 984 48 287 64 125 1328 1024 805 768 SUNXGA70 1024 X 768 70 041 56 596 74 250 1312 1024 808 768 SUNXGA77 1024 X 768...

Page 82: ...Way of packaging 2 1 Dynamic Color Depth 7 11 E Environment 3 1 Ambient Temperature Conditions 3 1 Condition check 3 1 Humidity Conditions 3 1 F FCC statement 1 1 File Service 7 2 Copy a file 7 7 Del...

Page 83: ...mma 7 10 Input Balance 7 12 Noise Reduction 7 12 Positioning the Projector 3 2 Power on Switching ON 4 1 Preset Input Balance 9 9 Programmable Function Keys 10 1 ProjectorAddress 5 8 Change ProjectorA...

Reviews: