background image

Safety Instructions

1-1

5975839 BARCOREALITY 812HS 050599

WARNING

TO PREVENT FIRE OR ELECTRICAL SHOCK

HAZARD, DO NOT EXPOSE THIS EQUIPMENT TO

RAIN OR MOISTURE

FEDERAL COMMUNICATION COMMISSION (FCC STATEMENT)

This equipment has been tested and found to comply with the limits

of a class A digital device, pursuant to Part 15 of the FCC Rules.  These

limits are designed to provide reasonable protection against harmful

interference  when  the  equipment  is  operated  in  a  commercial

environment.  This equipment generates, uses and can radiate radio

frequency energy and, if not installed and used in accordance with

the  instruction  manual,  may  cause  harmful  interference  to  radio

communications.  Operation of this equipment in a residential area is

likely to cause harmful interference in which case the user will be

required  to  correct  the  interference  at  his  own  expense.

Note :

The use of shielded cables is required to comply within the limits of

Part 15 of FCC rules and EN55022.

* All the safety and operating instructions should be read before using

this unit.

* The safety and operating instructions manual should be retained for

future  reference.

* All warnings on the equipment and in the documentation manuals

should be adhered to.

* All instructions for operating and use of this equipment must be

followed  precisely.

On safety

1

. This product should be operated from an  AC power source.

  This projector may be connected to an IT-power system.

Operating AC power voltage of the projector:

BARCO REALITY 812HS

Art.No. R9002180 (

230V AC

)

Art. No R9002189 

(120V AC)

Consult your dealer to switch over from 230Vac to 120 Vac or from

120Vac to 230 Vac.

If you are not sure of the type of AC power available, consult your

dealer or local power company.

2

.  This  product  is  equipped  with  a  3-wire  grounding  plug,  a  plug

having a third (grounding) pin. This plug will only fit into a grounding-

type power outlet. This is a safety feature. If you are unable to insert

the  plug  into  the  outlet,  contact  your  electrician  to  replace  your

obsolete outlet. Do not defeat the purpose of the grounding-type plug.

WARNING FOR THE CUSTOMERS

: THIS APPARATUS MUST BE

GROUNDED  (EARTHED)  via the supplied 3 conductor AC power

cable.

(If  the  supplied  power  cable  is  not  the  correct  one,  consult  your

dealer.)

A. Mains lead  (Power cord) with CEE 7 plug

:

The  wires  of  the  mains  lead  are  colored  in

accordance  with  the  following  code.

Green  and  yellow:earth  (safety  earth)

Blue:

neutral

Brown:

line (live)

1

SAFETY INSTRUCTIONS

Notice  on  Safety

This equipment is built in accordance with the requirements of the

international safety standards EN60950, UL 1950 and CSA C22.2

No.950, which are the safety standards of information technology

equipment including electrical business equipment.

These safety standards impose important requirements on the use

of  safety  critical  components,  materials  and  isolation,  in  order  to

protect the user or operator against risk of electric shock and energy

hazard, and having access to live parts.

Safety  standards  also  impose  limits  to  the  internal  and  external

temperature rises, radiation levels, mechanical stability and strength,

enclosure construction and protection against the risk of fire.

Simulated  single  fault  condition  testing  ensures  the  safety  of  the

equipment to the user even when the equipment's normal operation

fails.

INSTALLATION INSTRUCTIONS

Before  operating  this  equipment  please  read  this  manual

thoroughly,  and  retain  it  for  future  reference.

Installation  and  preliminary  adjustments  should  be

performed  by  qualified  BARCO  personnel  or  by  author-

ized  BARCO  service  dealers.

OWNER’S RECORD

The part number and serial number are located at the back side of the

projector.  Record  these  numbers  in  the  spaces  provided  below.

Refer to them whenever you call upon your BARCO dealer regarding

this  product.

PART NUMBER :

SER. NUMBER :

DEALER :

The  lightning  flash  with  an  arrowhead  within  a

triangle is intended to tell the user that parts inside this

product  may  cause  a  risk  of  electrical  shock  to

persons.
The exclamation point within a triangle is intended to

tell the user that important operating and/or servicing

instructions are included in the technical documen-

tation for this equipment.

Summary of Contents for R9002180

Page 1: ...R9002180 R9002189 OWNER S MANUAL REALITY 812HS...

Page 2: ......

Page 3: ...BARCO PROJECTION SYSTEMS Date 050599 Art No R5975839 R9002180 R9002189 OWNER S MANUAL REALITY 812HS Revision 00...

Page 4: ...ed by BARCO NV May 1999 All rights reserved Trademarks are the rights of their respective owners Printed in Belgium BARCOn v ProjectionSystems Noordlaan5 B 8520Kuurne Belgium Tel 32 56 368211 Fax 32 5...

Page 5: ...ith Tri level sync to port 4 5 3 5 Connecting a computer to the projector 3 6 Peripheral equipment 3 6 Connecting a RCVDS 05 switcher to the projector 3 6 Connecting a VS05 switcher to the projector 3...

Page 6: ...gence Adjustment 6 17 SERVICEMODE 7 1 Starting up the Service mode 7 1 Overview flowchart Service mode 7 1 Identification 7 2 Copy a block 7 2 Deletion of blocks 7 3 Deleting block by block 7 3 Deleti...

Page 7: ...replace your obsolete outlet Do not defeat the purpose of the grounding type plug WARNING FOR THE CUSTOMERS THIS APPARATUS MUST BE GROUNDED EARTHED via the supplied 3 conductor AC power cable If the s...

Page 8: ...ti reflective coating therefore avoid touching the lens To remove dust on the lens use a soft dry cloth Do not use a damp cloth detergent solution or thinner On repacking Save the original shipping ca...

Page 9: ...video 2x loop through BNC connector Allows a video tape recorder video camera color receiver monitor etc having video line output to be connected to the projector 9 75 ohm Termination Switch forVideo...

Page 10: ...emotecomputercontrolanddatacommunication CONTROL PANEL TERMINOLOGY a Gaining access to the keyboard The local keypath is mounted on the top plate of the electronic box b RCU control panel This remote...

Page 11: ...ed key to enter the address of the projector between 0 and 9 Press the address key followed by pressing one digit button between 0 and 9 4 STBY Stand by button To initiate remote power up operation To...

Page 12: ...the adjustment mode or to confirm an adjustment or selection in the adjustment mode 13 EXIT To leave the adjustment mode or to scroll upwards when in the adjustment mode 14 Control disc To make menu s...

Page 13: ...technician If you want to change this start up mode call a qualified technician Stand by indication lamp projector mode No light up projector switched off Green color projector in Operational mode Re...

Page 14: ...n 1 Comp Video 1 2 S Video1 Comp Video 2 3 RGB2 3 4 5 RGB2 4 or 5 4 5 Componentvideo3 6 4 5 RGB with Tri level sync4 7 4 5 Componentvideo withTri levelsync5 8 1 Input signal Y C luma chroma 2 Input si...

Page 15: ...3 luminancesignal Y 1Vpp 3dB Pin4 chrominancesignal C 300mVpp 3dB Forvideo Pin1 earth ground video Pin2 notconnected Pin3 videosignal Pin4 notconnected 21 2 POWER MAINS S HUL S K HU DOV 5 RPS 6 QF 9 6...

Page 16: ...UHT 6 HH L Q VWDOOD WLR Q L Q V WUXF WLR Q V EHI RU H FR QQ HFW L Q J W R WK H VXS SO 9 R LU O D QR W L FH G L Q VW D O O DW L RQ DYD QW GH U DFF RUG HU D X UpV HDX 9 P S 6 9 2 2 2 1 2 KP 9 2 JUHHQ RS...

Page 17: ...D XVH XQG HV LU HG RS HU DW L R Q 5 6 1 5 6 2 8 7 5 5 0 2 7 56 1 56 287 5 5 027 PORT 4 5 PORT 3 COMM PORT PORT 2 PORT 1 PROJECTOR MODE POWER MAINS 9 5 79 SOD HU RPSRVLWH YLGHR XGLR 2XW 21 2 POWER MAIN...

Page 18: ...ities address range from 0 to 255 b data communications sending data to the projector or copying the data from the projector to a hard memory device PERIPHERAL EQUIPMENT Connecting a RCVDS 05 switcher...

Page 19: ...e battery installation procedure Remove the battery cover on the backside of the RCU by pushing the indicated handle a little to the bottom of the RCU Lift up the top side of the cover at the same tim...

Page 20: ...WL Q J W R W KH V X S SO 9 RLU OD Q R WL F H G LQ V WD OOD WLR Q D Y D QW GH UD FF RUGHU D X Up VH D X 9 P S 6 9 2 2 21 2K P 9 2 J UH H Q R S H UD W LR Q UH G V W D QG E PORT2 PORT 1 2 21 2KP PROJECTO...

Page 21: ...GsB or RGBS RG3sB or RGB3S When a valid and available source is selected there will be informa tion displayed on the screen about that source if Text is on This information includes Source number Hori...

Page 22: ...ntrol is effective only when using the NTSC 4 43 or NTSC 3 58 system A bar scale gives a visual indication on the screen of the current tint setting while pressing the or buttons RCU If the bar scale...

Page 23: ...tor will be warned to call a qualified technician to perform the installation procedure see example of projected warning on the next page GUIDED Guided should be selected if the user intends to perfor...

Page 24: ...gits Enter the digits with the numeric keys on the RCU Example 2 3 1 9 For each digit entered a X appears on the screen under the displayed text enter password When your password is correct you gain a...

Page 25: ...USTMENT MODE Select a path from below GUIDED RANDOM ACCESS SERVICE IRIS Source 01 Select with or then ENTER EXIT to return ENTER continues to Setup Pattern Selection EXIT returns to Operational mode R...

Page 26: ...T TOP VLINEARITY COARSEADJUSTMENT From next page From next page SETUPPATTERNSELECTION FOCUSING BLUE GREEN RED BLUE GREEN RED REDANDBLUE BLUEANDGREEN REDANDGREEN COLORSELECT ORBITING CONTRASTMODULATION...

Page 27: ...ated for an external source connected to one of the inputs and the Genlocked Pattern is selected Internal Cross Hatch Pattern The Internal pattern menu will be displayed if the internal cross hatch pa...

Page 28: ...elect custom R B cut off with the control disc and press enter to start the adjustment Push the control disc or to adjust the red cut off and push the control disc or to adjust the blue cut off Select...

Page 29: ...HIGH FREQUENCY ClampTuning Highlight CLAMP TUNING by pushing the control disc or and press ENTER to toggle between NORMAL and RESTORATION Select Normal for all standard sources and all sources with a...

Page 30: ...ctive and OFF non active EXIT will return to the random access selection menu Select with or ENTER to accept EXIT to return PICTURE TUNING COLOR BALANCE SYNC FAST PORT2 S VIDEO LINE DOUBLER ON Color S...

Page 31: ...the left or to the right to adjust the top focusing Adjust until the upper part of the image is sharp ENTER to return to the Green Focusing menu Bottom image focusing The same procedure has to be rep...

Page 32: ...eft Right Corrections Left Side Corrections Top Bottom Corrections Horizontal Size Vertical Linearity Vertical Size Blanking The convergence corrections are disabled during geometry correc tions The b...

Page 33: ...LEFT RIGHT E W LEFT SIDE CORRECTION TOP BOTTOM N S H SIZE V LINEARITY V SIZE BLANKING ENTER will select green raster shift adjustment EXIT returns to random access adjustment mode menu Warning In ord...

Page 34: ...NE SKEW SIDE BOW SIDE KEYSTONE SEAGULL CORRECTION Warning Use this correction to adjust the right side of the image The warning Use this correction to adjust the right side of the image appears on the...

Page 35: ...tion insure that the side bow and keystone adjustments are done prior to these fine adjustments The following adjustments can be executed Left keystone Left bow Push the control disc or to highlight L...

Page 36: ...the vertical lines are straight To enter an alignment push the control disc or to highlight a function and press ENTER to activate this function Press EXIT to return TOP BOTTOM Select with or then EN...

Page 37: ...N S H SIZE V LINEARITY V SIZE BLANKING TOP BOTTOM N S H CENTERLINE BOW H CENTERLINE SKEW TOP KEYSTONE TOP BOW BOTTOM KEYSTONE BOTTOM BOW SEAGULL CORRECTION Horizontal Size Adjustment Pushthecontroldis...

Page 38: ...70 Vertical Size Adjustment Push the control disc forward or backward to highlight V SIZE on the Geometry menu and then press ENTER ENTER will select vertical size adjustment EXIT returns to random a...

Page 39: ...E BLANKING Select with or then ENTER EXIT to return BLANKING TOP BOTTOM LEFT RIGHT The following blanking corrections are possible Top blanking Bottom blanking Left blanking Right blanking Therefore I...

Page 40: ...ms are possible Horizontal sides adjust the vertical lines within a certain area on both sides without influencing the lines on the middle of the image Vertical corners adjust the horizontal lines in...

Page 41: ...isc to make horizontal or vertical convergence adjustments in the selected zone and then press ENTER to move the box to another zone or EXIT to return to the Convergence menu ENTER toggles arrow keys...

Page 42: ...Random Access Adjustment Mode 6 18 5975839 BARCOREALITY 812HS 060599...

Page 43: ...o the second menu or vice versa push the control disc forward or backward to select more Select with or then ENTER EXIT to return SERVICE MODE IDENTIFICATION COPY A BLOCK DELTE A BLOCK DELETE ALL BLOC...

Page 44: ...e control disc and press ENTER ENTER will select the highlighted item To copy the settings of a closed block to the block you are working on active block use the control disc to select a block All exi...

Page 45: ...e block nr 1 DELETE BLOCK The selected block will be deleted ENTER to confirm EXIT to cancel Push the control disc or to select the desired adjustment block Press ENTER to delete the selected adjustme...

Page 46: ...WORD Enter new password 0 0 0 0 Password will be reprogrammed as xxxx ENTER to confirm EXIT to cancel CHANGE PASSWORD IDENTIFICATION COPY A BLOCK DELTE A BLOCK DELETE ALL BLOCKS CHANGE PASSWORD CHANGE...

Page 47: ...When undo is pressed all settings are reset to the previous settings Convergence Mid Item is password protected Highlight convergence mid with the control disc and press ENTER to set all convergence s...

Page 48: ...OCK DELTE A BLOCK DELETE ALL BLOCKS CHANGE PASSWORD CHANGE LANGUAGE RUN TIME SET TO MIDPOSITION CONVERGENCE MID DYNAMIC ASTIGMATISM MORE DYNAMIC ASTIGMATISM ON SELECTED SOURCE RED GREEN BLUE ON GENLOC...

Page 49: ...eturn SERVICE MODE WARNING RISK OF INCORRECT ADJUSTMENT OF THE PROJECTOR THE GAMMA CORRECTIONS ARE FACTORY ADJUSTED USING AN ACTAS COLOUR ANALYSER THEREFORE ONLY QUALIFIED INSTALLTION OR SERVICE PERSO...

Page 50: ...witching on the the projector it starts immediately with the projection of the selected source CRT Drive Mode The projector CRT s can be driven with the normal current normal mode a lower current econ...

Page 51: ...electing an in put slot of an RCVDS where the input board is missing When selecting a new source information about this source will be displayed on the screen Source number horizontal and vertical fre...

Page 52: ...which the user has to answer FAILURE invalid RWI soft version Wrong software version in your projector Call for technical sup port FAILURE I2 C error addr 7FH3 Hardware failure Call a quali fied serv...

Page 53: ...nsfering and receiving data of projector settings Remote Control Simulation Advantage address range 0 to 255 Adjustment Data Where can it be located when a IBM PC or compatible or MAC or Workstation i...

Page 54: ...munication cables BARCO provides several cables to connect peripheral equipment to the projector a D9 D9 communication cable To connect an IBM PC or compatible to the projector To connect a RCVDS05 to...

Page 55: ...he block header A ADJUSTMENT BLOCKS AND SOURCE NUMBERS 90 99 Source numbers 90 99 Source numbers 90 99 do not correspond to physical inputs to the projector or RCVDS They are used to assign an additio...

Page 56: ...Adjustment Blocks and Source Numbers 90 99 A 2 5975839 BARCOREALITY 812HS 060599...

Reviews: