Installation Adjustments
7 - 7
5975987 BARCODATA 708 260597
CRT projection angle adjustment
The projection angle of the red and blue CRT's is dependent on the
desired size of the projected image. If the centers of green, blue and
red do not coincide, the CRT projection angle must be adjusted.
Never try to correct this misalignment with the shift correction or the
static convergence controls. These controls may only be applied to
correct small errors which cannot be corrected by the CRT angle
adjustment.
Ensure that the rasters are centered on the CRT face.
Press
ENTER to start the CRT angle adjustment procedure. A
crosshairs (green and red) will be displayed on the screen.
SW1
SW2
(SW2>SW1)
The same projection angle is mis-aligned for new
screen width SW2. Re-alignment is necessary.
Each screen width change requires readjust-
ment of the projection angle.
Projection angle correctly aligned
for screen width SW1
CRT PROJECTION ANGLE
ADJUSTMENT
<ENTER> to read more
<EXIT> to return
CRT PROJECTION ANGLE IS
THE FIRST STEP OF STATIC
CONVERGENCE ADJUSTMENT.
IT IS CRITICAL THAT THE
RASTERS ARE CENTERED ON
THE CRT FACE PLATES
PRIOR TO PERFORMING
THIS STEP.
...
CRT PROJECTION ANGLE
ADJUSTMENT
<ENTER> to continue
<EXIT> to return
DURING THIS PROCEDURE,
RED ON GREEN AND THEN
BLUE ON GREEN CROSSHAIRS
WILL BE DISPLAYED
TO ALLOW THE RED AND
BLUE CRTS TO BE ALIGNED
WITH THE GREEN CRT.
LOOSEN BOLTS A AND B
TO PIVOT THE RED CRT,
AND BOLDS C AND D
TO PIVOT THE BLUE CRT.
ENTER continues to the crosshairs alignment.
EXIT returns to raster shift adjustment
ADJUST returns to operational mode.
Summary of Contents for R9002120
Page 1: ...R9002120 INSTALLATION MANUAL DATA 708...
Page 2: ......
Page 3: ...BARCO PROJECTION SYSTEMS Date 260597 Art No R5975987 R9002120 INSTALLATION MANUAL DATA 708...
Page 6: ...Table of Contents i 2 5975987 BARCODATA 708 260597...
Page 10: ...Unpacking and Dimensions 2 2 5975987 BARCODATA 708 260597 Projector dimensions mm...
Page 16: ...Installation Set Up 4 4 5975977 BARCODATA 708 260597...
Page 18: ...Projector Set Up 5 2 5975987 BARCODATA 708 260597...
Page 30: ...Installation Adjustments 7 10 5975987 BARCODATA 708 260597...