Service Mode
7-9
5975039 BARCOVISION 508 120198
the CRT run in cycle will start when pressing ENTER. If no such a
block is available, the projector cannot run the CRT run in option and
leaves the adjustment mode.
If you still want to run CRT run in cycle, create first a memory block
on an internal # pattern and restart the CRT run in option.
ENTER
starts the 'CRT run in' when an internal generated # pattern
is available.
EXIT
returns to the Path Selection main menu.
CRT RUN IN CYCLE
All flashing white pattern
will be generated until
<EXIT> is pressed.
The projector only uses
memory blocks adjusted
on an internal # pattern;
if no such block is
available, the projector
can't run the procedure
and leaves the adjustment
mode
<ENTER> to continue
<EXIT> to cancel
I2C Diagnostics
Highlights 'I2C Diagnostics' by pushing the control disc up or down
and press
ENTER
.
The I2C diagnostics menu gives an overview of the I2C failures inside
the projector.
To scroll through the failure list, push the control disc up or down.
The I2C address, IC number and module name will be given in I2C
diagnostic menu.
When no errors are detected, the following message will appear on
the screen :
"No errors on i2c-bus detected".
Select with or
then <ENTER>
<EXIT> to return.
SERVICE MODE
PROJECTOR SET-UP
MEMORY MANAGEMENT
COMMON SETTINGS
I2C DIAGNOSTICS
Scroll with or
then <ENTER>
<EXIT> to return.
I2C DIAGNOSTICS
Failures :
addr
IC number
mod.name
48H
IC200
DECODER