3. Installation Guidelines
3.5.1
Access to the Lamp Unit.
What has to be done
To access the lamp casing, a side panel has to be removed.
Necessary tools
A flatblade screwdriver of 5 mm
Removing the side panel
1. Turn with a screwdriver the side panel lock screw a quarter turn counter clockwise. (image 3-7)
2. Pull the right side of the panel towards you and further to the right to remove. (image 3-8)
Image 3-7
Unlocking the side cover
Image 3-8
Pull and remove the side cover
3.5.2
Installation of the new Lamp Unit.
What has to be done
First remove the lock nut on each spacer screw and next slide the lamp unit into the projector frame.