4. Components of an OLite rental tile
Input/output ports of the OLite control box
The illustration below shows the different connection ports of the OLite control box. At the left side of the illustration you can see the
front view of the OLite control box with the power/data input/output ports used to realize the power and data connections from tile
to tile. At the right side of the illustration below you can see the bottom view of the OLite control box with the six power/data output
ports where a cable string can be plugged in leading to the OLite modules.
1
2
3
4
5
6
C
D
B
A
1
3
5
2
4
6
Image 4-9
A
Data output port.
B
Data input port.
C Power input socket.
D Power output socket.
1
Power/data output port number 1 (to first string of OLite modules).
2
Power/data output port number 2 (to second string of OLite modules).
3
Power/data output port number 3 (to third string of OLite modules).
4
Power/data output port number 4 (to fourth string of OLite modules).
5
Power/data output port number 5 (to fifth string of OLite modules).
6
Power/data output port number 6 (to sixth string of OLite modules).
Each output port can place a dedicated color upon the OLite modules. This makes the identification of the OLite module strings
easier.
•
Port 1 : Red
•
Port 2 : Green
•
Port 3 : Blue
•
Port 4 : White
•
Port 5 : Magenta
•
Port 6 : Cyan
In a standard OLite rental tile the power/data output ports number 5 and 6 are not used but sealed with a
dummy plug (Z3499467). Four strings of OLite modules are sufficient to fill the grid of an OLite rental frame.
Using an OLite control box as stand alone re-sync unit
The OLite control box acts like a stand alone re-sync unit in case no power is applied to the power input socket of the control box.
When you use the OLite control box as stand alone re-sync unit ensure to place dummy plugs upon the power input and output
sockets. Maximum connect three (3) stand alone re-sync units in series. The cable length used between two control boxes may not
exceed 5 meter.
Power cables used between OLite control boxes
To meet the demands of each OLite application Barco offers several lengths of power cables to link power from control box to control
box. Note that the power output port of the last OLite control box in the power chain has to be sealed with a dummy power plug.
R5976832 OLITE RENTAL DISPLAY 15/12/2004
15
Summary of Contents for OLite 510
Page 1: ...OLite rental display Installation manual R5976832 00 15 12 2004...
Page 4: ......
Page 10: ...1 Safety 6 R5976832 OLITE RENTAL DISPLAY 15 12 2004...
Page 12: ...2 Installation requirements 8 R5976832 OLITE RENTAL DISPLAY 15 12 2004...
Page 14: ...3 System overview 10 R5976832 OLITE RENTAL DISPLAY 15 12 2004...
Page 22: ...4 Components of an OLite rental tile 18 R5976832 OLITE RENTAL DISPLAY 15 12 2004...
Page 46: ...7 Basic set up procedures 42 R5976832 OLITE RENTAL DISPLAY 15 12 2004...
Page 52: ...8 Cabling of an OLite rental display 48 R5976832 OLITE RENTAL DISPLAY 15 12 2004...
Page 54: ...9 Maintenance 50 R5976832 OLITE RENTAL DISPLAY 15 12 2004...
Page 64: ...A Dimensions 60 R5976832 OLITE RENTAL DISPLAY 15 12 2004...
Page 70: ...C Order info 66 R5976832 OLITE RENTAL DISPLAY 15 12 2004...