R5906141 /02
Medea series
47
Apply Scheimpflug correction
1.
Loosen the three set screws (reference 1b, 2b, 3b). Use a size 5 hex key to do this.
1b
2b
3b
Image 5-14
2.
Adjust the left side Scheimpflug adjustment screw (reference 1) until the test image in the bottom right side of
the screen is in focus. Use a size 4 hex key to do this.
Note:
This process may cause the other areas of the image to slide out of focus. This is totally normal.
F
1
Image 5-15
3.
Adjust the right side Scheimpflug adjustment screw (reference 2) until the test image in the bottom left side of
the screen is in focus. Use a size 4 hex key to do this.
Note:
This process may cause the other areas of the image to slide out of focus. This is totally normal.
F
2
Image 5-16
4.
Adjust the bottom Scheimpflug adjustment screw (reference 3) until the test image in the top half of the screen
is in focus. Use a size 4 hex key to do this.
Note:
This process may cause the other areas of the image to slide out of focus. This is totally normal.