5. Advanced operation
The available reading rooms for your Nio 5MP LED Display are:
CR/DR/ MAMMO
Corresponds to light conditions in diagnostic
reading rooms for computed radiology, digital
radiology or mammography. This setting has the
lowest maximum ambient light.
CT/MR/NM
Corresponds to light conditions in diagnostic
reading rooms for computed tomography, magnetic
resonance or nuclear medicine scans.
Staff Of
fi
ce
Corresponds to light conditions in of
fi
ce rooms.
Clinical Viewing Room
Corresponds to light conditions in diagnostic
reading rooms for clinical viewing.
Emergency Room
Corresponds to light conditions in emergency
rooms.
Operating Room
Corresponds to light conditions in operating rooms.
This setting has the highest maximum ambient light.
To select a reading room:
1. Bring up the OSD main menu.
2. Navigate to the
Con
fi
guration > Calibration > Ambient Light
menu.
3. Enter the
Reading Room
submenu.
4. Select one of the available reading rooms and con
fi
rm.
5.15 Embedded QA
Overview
•
•
•
•
•
•
5.15.1 About Embedded QA
About
Embedded QA allows you to run a display calibration or compliance test directly from the display using the
OSD menus described in the next sections. Embedded QA will use the front sensor / I-Guard to measure
the necessary luminance levels for either a calibration or compliance test. Various settings for both actions
can be selected from the display’s OSD menu. The last results of both actions can be consulted from the
OSD.
Embedded QA or MediCal QAWeb?
Embedded QA is not a replacement for the Barco MediCal QAWeb solution.
Although Embedded QA is a reliable option to perform a simple calibration or compliance test, Barco still
highly recommends MediCal QAWeb as the solution of choice for calibration and QA. Medical QAWeb
brings many bene
fi
ts such as centralized asset management, the ability to schedule tasks, remote man-
agement, automated reporting, alerting and speci
fi
c support of regional QA standards such as DIN 6868-
57, JESRA and AAPM TG18. That’s why MediCal QAWeb Agent acts as the master for all supported dis-
plays from the moment it is installed and running. MediCal QAWeb Agent will take over from Embedded
QA and overwrite any settings which were applied by Embedded QA.
K5902091 NIO 5MP LED DISPLAY 09/01/2015
25
Summary of Contents for MDNG-5221
Page 1: ...Nio 5MP LED Display User Guide MDNG 5221 K5902091 02 09 01 2015...
Page 10: ...2 Parts controls and connectors 8 K5902091 NIO 5MP LED DISPLAY 09 01 2015...
Page 20: ...4 Daily operation Cancel Standby IEC 60417 5009 18 K5902091 NIO 5MP LED DISPLAY 09 01 2015...
Page 34: ...5 Advanced operation 32 K5902091 NIO 5MP LED DISPLAY 09 01 2015...
Page 38: ...7 Cleaning your display 36 K5902091 NIO 5MP LED DISPLAY 09 01 2015...