3. Troubleshooting
Error 2001 : “Mains voltage to low”
Situation
Solution
The mains voltage applied to the
“MAINS INPUT” sockets of the LPS
module is to low.
•
Check if the main power cables (image 3-9) are connected with the “MAINS
INPUT” sockets of the LPS module.
•
Check if the mains voltage applied to the projector power socket is between 200
and 240 VAC.
•
Make sure that the electrical dimensions of the extension leads to the projector
meet the power requirements of the projector.
Image 3-9
Error 2002 : “Lamp start failed”
The Lamp Power Supply succeeded in igniting the lamp but shortly after ignition the lamp goes out.
Situation
Solution
Hot restrike of the lamp. The lamp
fails to illuminate when switched on
shortly after the lamp was switched
off.
Let cool down the lamp for at least 3 minutes before switching the projector from
standby to operating mode.
Lamp with many strikes, maximum
run time exceeded. The Lamp
Power Supply and the Start Pulse
Generator are working normally.
Nevertheless, the lamp fails to
illuminate.
Replace the exhausted lamp with a new one.
Malfunction SPG unit. You can not
hear the SPG module three times
clicking in an attempt to ignite the
lamp. The voltage on the “LAMP
OUT” pins of the LPS module is first
140 volt during the attempt to ignite
and then drops to 0 volt after a few
minutes.
Note
: The ambient noise must be
low to hear the SPG clicking in an
attempt to ignite the lamp.
•
Check the cabling of the SPG module.
•
Replace the SPG module.
Error 2004 : “Lamp goes out”
Situation
Solution
Exhausted lamp. Lamp with
many strikes, maximum run time
exceeded.
Replace the exhausted lamp with a new one.
22
R59770072 FLM SERIES 19/03/2007
Summary of Contents for FLM series
Page 1: ...FLM series Service manual R59770072 00 19 03 2007...
Page 6: ...Table of contents 4 R59770072 FLM SERIES 19 03 2007...
Page 10: ...1 Safety 8 R59770072 FLM SERIES 19 03 2007...
Page 86: ...6 Removal and installation of projector covers 84 R59770072 FLM SERIES 19 03 2007...
Page 96: ...8 Lamp and lamp house 94 R59770072 FLM SERIES 19 03 2007...
Page 102: ...9 Input communication unit 100 R59770072 FLM SERIES 19 03 2007...
Page 125: ...13 Cold mirror assembly Image 13 5 Remove of cold mirror R59770072 FLM SERIES 19 03 2007 123...
Page 130: ...13 Cold mirror assembly 8 Reinstall the side cover 128 R59770072 FLM SERIES 19 03 2007...
Page 133: ...14 Lens holder F Image 14 4 R59770072 FLM SERIES 19 03 2007 131...
Page 140: ...14 Lens holder 138 R59770072 FLM SERIES 19 03 2007...
Page 154: ...15 Vertical and Horizontal shift motors 152 R59770072 FLM SERIES 19 03 2007...
Page 180: ...16 FLM liquid cooling circuit 178 R59770072 FLM SERIES 19 03 2007...
Page 190: ...17 Heat exchanger 188 R59770072 FLM SERIES 19 03 2007...
Page 204: ...18 Cooling pump 202 R59770072 FLM SERIES 19 03 2007...
Page 208: ...19 Shutter replacement 206 R59770072 FLM SERIES 19 03 2007...
Page 212: ...20 Formatter Interface Board 210 R59770072 FLM SERIES 19 03 2007...
Page 217: ...21 Pixel map processor board Image 21 7 PMP removal R59770072 FLM SERIES 19 03 2007 215...
Page 220: ...21 Pixel map processor board 218 R59770072 FLM SERIES 19 03 2007...
Page 228: ...22 LCD panel replacement 226 R59770072 FLM SERIES 19 03 2007...
Page 234: ...23 Keypad board replacement 232 R59770072 FLM SERIES 19 03 2007...
Page 288: ...25 Peltier replacement 286 R59770072 FLM SERIES 19 03 2007...
Page 314: ...28 Start pulse generator 312 R59770072 FLM SERIES 19 03 2007...
Page 326: ...Glossary 324 R59770072 FLM SERIES 19 03 2007...