background image

MENU

Menu Navigate Toggle OSD 
Menu

GP3, GP4

Set

End User

NVUP

Menu Navigate Up

GP3, GP4

Set

End User

NVDW

Menu Navigate Down

GP3, GP4

Set

End User

NVLF

Menu Navigate Left

GP3, GP4

Set

End User

NVRH

Menu Navigate Right

GP3, GP4

Set

End User

NVOK

Menu Navigate Ok

GP3, GP4

Set

End User

ECHO

Communication Response 
(on/off)

GP3, GP4

Set

End User

LANG

Language

GP3, GP4

Get, Set

End User

SINF

Show OSD Info

GP3, GP4

Set

End User

CWI1

Color Wheel Index 1

GP3

Get, Set

Power User

CWI2

Color Wheel Index 2

GP3

Get, Set

Power User

CRST

Reset All Counters

GP3, GP4

Set

Manufacturing

MAYR

Manufacture Year

GP3, GP4

Get

Manufacturing

MAWE

Manufacture Week

GP3, GP4

Get

Manufacturing

LFMP

LFM Performed 

GP3, GP4

Set

Power User

GPEN

Enable Power User Gammas

GP3, GP4

Get, Set

Power User

AFCL

AD Factory Calibrate

GP3, GP4

Set

Manufacturing

LSDI

Lens shift disable

GP3, GP4

Get, Set

Power User

0 - enable 1 - disable

BCPE

Enable Power User brilliant color 
modes

GP3

Get, Set

Power User

0 - enable 1 - disable

STRS

Skip reset timeout (mirror 
exercise)

GP3

Get, Set

Manufacturing 0 - do not skip 1 - skip 

(WQXGA only)

CALM

LED Calibration mode 

GP3 LED

Get, Set

Power User

0 - disable, 1 - enable

LVCA

LED voltage calibration start

GP3 LED

Set

Service Partner

LVCS

LED voltage calibration status

GP3 LED

Get

Service Partner 0 - done, 1 - in progress, 2 - 

failed

LVCE

LED voltage calibration error 
code

GP3 LED

Get

Service Partner bit wise error code see value 

table LVCE

LIVR

LED input voltage red

GP3 LED

Get

Service Partner

LIVG

LED input voltage green

GP3 LED

Get

Service Partner

LIVB

LED input voltage blue

GP3 LED

Get

Service Partner

LDVR

LED drop out voltage red

GP3 LED

Get

Service Partner

LDVG

LED drop out voltage green

GP3 LED

Get

Service Partner

LDVB

LED drop out voltage blue

GP3 LED

Get

Service Partner

UINV

Update internal sensor values 
factory

GP3 LED

Set

Manufacturing

UIVU

Update internal sensor values 
user

GP3 LED

Set

Power User

INCS

Internal sensor calibration status

GP3 LED

Get

Power User

0 - done, 1 - in progress, 2 - 
failed

INCE

Internal sensor calibration error 
code

GP3 LED

Get

Power User

bit wise error code see value 
table INCE

INTR

Internal sensor value red

GP3 LED

Get

Power User

INTG

Internal sensor value green

GP3 LED

Get

Power User

INTB

Internal sensor value blue

GP3 LED

Get

Power User

INDR

Internal sensor duration value red

GP3 LED

Get

Power User

Menu navigate

Miscellaneous 

Service->LED calibration

Service

3. ASCII Command Sets

601-0381-00_GP3/GP4 

Sicilium_1_24

14

Summary of Contents for FL35

Page 1: ...F L 35 FS35 IR F85 ASCII Commands Protocol Reference Manual 601 0381 00 00 21 10 2015...

Page 2: ...Barco Fredrikstad AS Habornveien 53 N 1630 Gamle Fredrikstad Norway Phone 47 6930 4550 Fax 47 6930 4580 Support Support fre barco com Visit us at the web www barco com Printed in NO...

Page 3: ...ed in new editions of this publication The latest edition of Barco manuals can be downloaded from the Barco web site www barco com or from the secured Barco web site https www barco com en signin Copy...

Page 4: ......

Page 5: ...may take up to a minute for the projector to receive IP settings from the DHCP server The IP address will be updated and shown in the OSD If there is no DHCP server in the network the projector will b...

Page 6: ...1 Communication settings Maximum length of the RS 232 cable is 15 25m 50ft 2 601 0381 00 F L 35 FS35 IR F85 21 10 2015...

Page 7: ...g 20 commands Minimum 5 seconds delay required 2 2 Serial Communications Protocol Definitions Like every communication method the serial communication uses a particular protocol ANSI which must be res...

Page 8: ...r then an ACK command is sent back The ACK command uses the following protocol Ack Address Separator Command Separator Value Terminator Limitations 1 byte 1 3 bytes 1 byte 4 bytes 1 byte 6 bytes 1 byt...

Page 9: ...ightness Command Description CNTR R1 CR Increase contrast 001 CNTR 000061 CR Acknowledge increase contrast Command Description CNTR R 2 CR Decrease contrast 001 CNTR 000059 CR Acknowledge decrease con...

Page 10: ...abs value GP3 GP4 Get Set End User See value table SABS S1T1 Select Scaling 1 1 GP3 GP4 Get Set End User S169 Select Scaling 16 9 GP3 GP4 Get Set End User SS43 Select Scaling 4 3 GP3 GP4 Get Set End...

Page 11: ...Set End User 0 temperature 1 coordinate CMXV Color Management X Coordinate GP3 GP4 Get Set End User CMYV Color Management Y Coordinate GP3 GP4 Get Set End User CMTV Color Management Temperature GP3 G...

Page 12: ...Set Manufacturing DFWG Factory Desired White Gain GP3 GP4 Get Set Manufacturing MSRX Measured Red X GP3 GP4 Get Set End User MSRY Measured Red Y GP3 GP4 Get Set End User MSRL Measured Red Luminance G...

Page 13: ...ntrast offset blue GP3 GP4 Get Set End User DESK Select orientation Desktop Front GP3 GP4 Get Set End User CEIL Select orientation Ceiling Front GP3 GP4 Get Set End User RDES Select orientation Deskto...

Page 14: ...t Set End User 0 Off 1 Frame lock 2 Pass through FLST Frame lock Status GP3 GP4 Get End User Print current frame lock status TSLR 3D source L R sync GP3 GP4 Get Set End User 0 None 1 BNC sync in TDLR...

Page 15: ...ble GP3 LED IR Get Set End User 0 disable 1 enable DISL RGB LEDs enable GP3 LED IR Get Set End User 0 disable 1 enable LDMM LED Dim Mode GP3 LED IR Get Set End User 0 standard 1 custom LPW1 LED Power...

Page 16: ...et End User 1 Slow 2 Medium 3 Fast IRCL Iris Close GP3 GP4 Set End User 1 Slow 2 Medium 3 Fast LSDW Lens Shift Down GP3 GP4 Set End User 1 Slow 2 Medium 3 Fast LSUP Lens Shift Up GP3 GP4 Set End User...

Page 17: ...er 0 disable 1 enable LVCA LED voltage calibration start GP3 LED Set Service Partner LVCS LED voltage calibration status GP3 LED Get Service Partner 0 done 1 in progress 2 failed LVCE LED voltage cali...

Page 18: ...form Name String GP3 GP4 Get Power User Extended Protocol SERI Serial Number String GP3 GP4 Get Power User Extended Protocol MODL Model Name String GP3 GP4 Get Power User Extended Protocol PART Part N...

Page 19: ...ta 0 Lamp 1 1 Lamp 2 LMBP Lamp data mailbox position GP3 Get Set Manufacturing Data 0 Lamp 1 1 Lamp 2 LMBC Lamp data mailbox checksum GP3 Get Set Manufacturing Data 0 Lamp 1 1 Lamp 2 Lamp data 3 ASCII...

Page 20: ...p is cooling down 5 Lamp is not present GABS Set Gamma abs value Value Description 0 Film 2 2 1 Film 2 8 2 Video 1 3 Video 2 4 Film 2 4 5 Film 2 6 7 Computer 1 8 Computer 2 9 Linear when available 10...

Page 21: ...ue Description Value Description Value Description 0 Off 0 Off 0 VizSim 1 Computer balanced 1 Video 1 High Brightness 2 Video balanced 2 SRP Full when available 2 SRP 8ms 3 Computer native 3 Computer...

Page 22: ...Target Description Value 0 4 3 1 5 4 on 0 2 16 9 off 1 3 16 10 no change 2 4 2 35 1 5 no source 6 standby EDIR Edid resolution Target Description Value Auto 0 Custom not implemented 1 VGA 2 SVGA 3 XGA...

Page 23: ...assthrough FLSS Framelock signal status Value Description 0 free running 3 locked TDSS 3D LR Signal status Value Description 0 free running 1 drifting free running 2 drifting locked 3 locked TDSM 3D s...

Page 24: ...C current failed 22 Read blue drop out voltage failed 23 Desired blue input voltage out of range 24 Blue loop count exceed max value INCE bit wise error code for LED sensor calibration Bit Description...

Reviews: