2. Communication protocol definitions
Error code
Error message
Description
!00002
Not available
Logic con
fl
ict prevents command being available. For example, contrast is not
available when the projector is searching for sources.
!00003
Not implemented
Command not available for this projector con
fi
guration. See relevant comments
section in ASCII commands for information.
!00004
Value out of range
Value is not within valid range.
2.3
Examples
SET commands
Command
Description
:POWR1’CR’
Set power on
%001 POWR 000001’CR’
Acknowledge power on
Command
Description
:BRIG 60’CR’
Set brightness to 60
%001 BRIG 000060’CR’
Acknowledge brightness
Command
Description
:CNTR R1’CR’
Increase contrast
%001 CNTR 000061’CR’
Acknowledge increase contrast
Command
Description
:CNTR R-2’CR’
Decrease contrast
%001 CNTR 000059’CR’
Acknowledge decrease contrast
SET commands with target
Command
Description
:TATB 1 3’CR’
Set aspect trigger behavior 16:10 to off
%001 TATB 000001’CR’
Acknowledge set aspect trigger behavior 16:10 to off
GET commands
Command
Description
:CNTR?’CR’
Get current value contrast
%001 CNTR 000059’CR’
Acknowledge get current value contrast
Command
Description
:BRIG ?N’CR’
Get minimum value brightness
%001 CNTR 000000’CR’
Acknowledge get minimum value brightness
GET commands with target
Command
Description
:TATB ? 3
Get aspect trigger behavior 16:10
%001 TATB 000001 ’CR’
Acknowledge get aspect trigger behavior 16:10
601–0381–00 F(L)35, FS35 IR, F85 21/10/2015