MFBX
Factory Measured Blue X
GP3, GP4
Get, Set
Manufacturing
MFBY
Factory Measured Blue Y
GP3, GP4
Get, Set
Manufacturing
MFBL
Factory Measured Blue
Luminance
GP3, GP4
Get, Set
Manufacturing
MFWX
Factory Measured White X
GP3, GP4
Get, Set
Manufacturing
MFWY
Factory Measured White Y
GP3, GP4
Get, Set
Manufacturing
MFWL
Factory Measured White
Luminance
GP3, GP4
Get, Set
Manufacturing
MFDX
Factory Measured BC1 X
GP3
Get, Set
Manufacturing
MFDY
Factory Measured BC1 Y
GP3
Get, Set
Manufacturing
MFDL
Factory Measured BC1
Luminance
GP3
Get, Set
Manufacturing
MFEX
Factory Measured BC2 X
GP3
Get, Set
Manufacturing
MFEY
Factory Measured BC2 Y
GP3
Get, Set
Manufacturing
MFEL
Factory Measured BC2
Luminance
GP3
Get, Set
Manufacturing
CMTP
Color Management Test Patterns
GP3, GP4
Get, Set
End User
IBCO
Individual brightness and contrast
offset adjustments
GP3, GP4
Get, Set
End User
0 - disable, 1 - enable
0-RGB, 1-IR
(if available)
BOR0
Brightness offset red
GP3, GP4
Get, Set
End User
BOG0
Brightness offset green
GP3, GP4
Get, Set
End User
BOB0
Brightness offset blue
GP3, GP4
Get, Set
End User
COR0
Contrast offset red
GP3, GP4
Get, Set
End User
COG0
Contrast offset green
GP3, GP4
Get, Set
End User
COB0
Contrast offset blue
GP3, GP4
Get, Set
End User
DESK
Select orientation - Desktop Front
GP3, GP4
Get, Set
End User
CEIL
Select orientation - Ceiling Front
GP3, GP4
Get, Set
End User
RDES
Select orientation - Desktop Rear
GP3, GP4
Get, Set
End User
RCEI
Select orientation - Ceiling Rear
GP3, GP4
Get, Set
End User
ORIE
Select orientation - Absolute
value
GP3, GP4
Get, Set
End User
See value table ORIE
SCAN
Source Scan
GP3, GP4
Get, Set
End User
0 - disable, 1 - enable
IR01
IR Enable 1
GP3, GP4
Get, Set
End User
0 - disable, 1 - enable
IR02
IR Enable 2
GP3, GP4
Get, Set
End User
0 - disable, 1 - enable
IR03
IR Enable 3
GP3
Get, Set
End User
0 - disable, 1 - enable
OSDC
OSD Enable
GP3, GP4
Get, Set
End User
See value table OSDC
TEST
Test Image
GP3, GP4
Get, Set
End User
0 - 7 different test patterns
DHED
Dual Head Setup Mode
GP3, GP4
Get, Set
End User
0 - off, 1 - side by side
SVGA
Sync termination VGA
GP3, GP4
Get, Set
End User
0 - 2.2kOhm, 1 - 75Ohm
SNCL
Sync level VGA
GP3, GP4
Get, Set
End User
0-255
SNCS
Sync Level SOG
GP3, GP4
Get, Set
End User
0-31
Infitec only
OPFI
Infitec filter
GP3
Get, Set
End User
0 - disable, 1 - enable
Infitec only
CSCC
Infitec CSC
GP3
Get, Set
End User
0 - disable, 1 - enable
EDIR
Edit resolution
GP3, GP4
Get, Set
End User
See value table EDIR
EDIT
Edid type
GP3, GP4
Get, Set
End User
See value table EDIT
Installation
Picture->Advanced->Source Correction
3. ASCII Command Sets
601-0381-00_GP3/GP4
Sicilium_1_24
10