background image

The Lamp does not strike

The Lamp does not strike

The image appears dim

The image appears dim

Creating a Diagnostic Package

Creating a Diagnostic Package

Button backlight colors

Button backlight colors

DP2K S-series

    

Quick Start Guide 

1

1

1
2

3

4

2

2

Press 

Standby

 button. Between each strike attempt, allow 10 

seconds (if lamp is cold) or 1 minute (if lamp is hot).
If after te third attempt the lamp does not strike, check with 
communicator for errors, then contact the theatre’s techni-
cian.

In Communicator or on the Touch panel, select Control tab 
and press Service button.
Check the Current Light Output reading. If the light output 
does not indicate at least 11 Fl, contact the theater technician

In Communicator, press Diagnostic tab and click Package.
Click on Create diagnostics package.

1

2

3

4

Reselect the proper 

Macro

 button on the projector for the 

current movie.
Use the 

Test Pattern

 button to select color bars. Check that 

red, green and blue can all be seen.
Reselect the current 

Macro

 button again for the current 

movie.
Restart the projector and server and try to replay the movie. 
Let the lamp cool down for at least 1 minute prior to 
restarting

1
2
3
4
5
6

7

Check to see if the lamp is on and the dowser is open.
Check that the lens cap is removed.
Verify that the correct macro is selected.
Verify that the server is playing.
Verify the operation of the projector with a Test pattern.
Check all connection between projector and server. Try 
playing different content.
Restart projector and server. Try to play the movie again. Let 
the projector lamp cool down for at least one minute prior to 
restarting.

Red = Error condition.

  Restart the projector if the 

status light turns green, problem is resolved. Check 
Communicator or Touch panel for ‘red’ marked error 
messages. If you find an error, report it ot the 
theatre technician.

Yellow = Warning condition.

 Check Communicator or 

Touch panel for ‘yellow’ marked warning messages 
and take action accordingly.

Blue = Maintenance notification.

  Check Communi-

cator or Touch panel for ‘blue’ marked messages 
and perform the suggested maintenance.

1

2
3
4

Check the booth’s ambient temperature.
These must be between:
 

* 50 - 95 degrees Fahrenheit

 

* 10 - 35 degrees Celsius 

Check that the extraction system is operating.
Check that the filters are clean.
Contact the theater technician.

Browse to the storage location, accept the proposed file  
name or change the name.

Click Save to create the diagnostics package. Once finished, 
send this package to a technician for analyse purposes.

Troubleshooting

Content is distorted or not playing with the 
correct color

The projector indicates an overheating error

There is no image on the screen

The projector status light is solid red, yellow 
or blue

Button enabled. Default backlight color.
Button pressed.  Request is ongoing.

Standby

Sleep

Macro

 = function is activated

Dowser

 = dowser open, Test pattern = no pattern selected.

Standby

 = lamp is off, Dowser = dowser closed

Test pattern

 = test pattern selected

Shift

Zoom

Focus

 = end of range

Macro

 = error in at least one step

Numeric buttons = 

Key

 button pressed.

Trained projectionist

7

C

M

Y

CM

MY

CY

CMY

K

r5905465_00_userguide.pdf   7   17-12-2012   9:20:17

Summary of Contents for DP2K S-series

Page 1: ...removes heat from lamp house Must be connected to external extraction system Important the extraction system must be running A flexible duct must be installed Touch panel position places where a touch panel can be mounted Status light shows the status of the projector Can be green yellow red or blue Mains power switch powers projector on and off Shuts off all electrical connections Important the l...

Page 2: ...ling fans remain active for about 5 minutes Dowser button opens or closes the electronic dowser Test pattern button opens directly the internal test patterns Press again to scroll to next pattern Lens focus button to focus the image on the screen Lens shift button to shift the image up down or left right Sleep button press 3 seconds to put projector in sleep mode Press sleep again to put projector...

Page 3: ...r Optional if the image is not aligned with the screen masking use the Lens adjustment buttons to correct the image on screen Be sure to notify the theatre technician General Ensure that the exhaust system is properly installed Press the Power Switch to switch the projector ON Allow up to one minute for the projector to finish the boot up sequence Note projector starts up in the same state as it w...

Page 4: ...t but doesn t feel greasy then vacuum clean the dust filter Attach a clean dust filter to the cover plate Ensure that both latches and both mounting lips of the dust filter are engaged Install the dust filter assembly back at the front side of the projector Secure both captive screws Ensure that both mounting lips of the assembly are engaged in the projector chassis Lens Always wipe lenses with a ...

Page 5: ... dust filter Attach a clean dust filter to the cover plate Ensure that both latches and both mounting lips of the dust filter are engaged Install the dust filter assembly back at the front side of the projector Secure the captive screw Ensure that the mounting lip of the assembly is engaged in the projector chassis Make a solution with a ratio of 30 gram handful sodium carbonate to 1 liter hot wat...

Page 6: ...ver Check the image on screen for the proper alignment and color Optional if the image is not aligned with the screen masking use Configuration Lens Lens settings to correct the image on screen Be sure to notify the theatre technician No extra software installation required Make sure your PC and projector are connected to the same LAN Open your webbrowser and type in the hostname or IP address of ...

Page 7: ...t Restart projector and server Try to play the movie again Let the projector lamp cool down for at least one minute prior to restarting Red Error condition Restart the projector if the status light turns green problem is resolved Check Communicator or Touch panel for red marked error messages If you find an error report it ot the theatre technician Yellow Warning condition Check Communicator or To...

Reviews: