9. ICMP
In case the ICMP has to be returned to factory (e.g. for repair) the non defective HDDs should be removed and
kept.
9.11 ICMP con
fi
guration via Communicator
About ICMP con
fi
guration
Following parameters are available to con
fi
gure the ICMP:
•
Global settings: allows de
fi
ning name of the ICMP, host name (network identi
fi
er) and IP address which can be used for com-
munication with external content devices.
•
User settings: de
fi
nition of all users allowed on the ICMP.
•
Server settings: de
fi
nition of access to servers and storage libraries of content (movies, KDM, etc.).
•
Player settings: Audio delay and audio output frequency.
•
Audio channel: allows de
fi
ning the mapping of audio channels (content) on each audio output (AES outputs of the ICMP).
•
Scheduler setting: Enable/Disable scheduler at startup, delays allowed in scheduler mode and length of schedule history.
•
Devices: allows de
fi
ning communication ports settings, to access external devices controlled by the automation.
•
Automation Cues: event cues that are triggered from different sources and to which can be assigned actions to be executed
by the automation engine.
•
Verify internal clock of the ICMP.
All installation and maintenance operations on the ICMP are performed via Communicator, the Barco con
fi
g-
uration software. Please refer to the Communicator user guide for further information.
About Default settings
The restore of factory setting is a feature that allows removing all settings performed on the ICMP and replaces them with the default
values set at the factory. Please refer to the Communicator user guide for further information.
About the ICMP internal clock
The crystal on the ICMP board that manages the clock shows a certain drift (all crystals do). With the Communicator the internal
clock can be adjusted. This maintenance action should be repeated every 3 months. When neglected the system will locks up.
From ICMP software version 1.2.1 onwards it is possible to enable NTP (Network Time Protocol). You have to con
fi
gure (at instal-
lation) an IP address where the ICMP can
fi
nd a sync signal. From then on, and as long as the connection is active, the ICMP will
automatically keep its clock correct. For detailed instructions see user guide of the Communicator.
9.12 ICMP reset
This procedure requires that ICMP version 1.2.4 or later is installed.
ICMP reset possibilities
•
The Star button on the local keypad (Not for C- and B-series)
•
The ICMP reset button in the GUI of the Communicator.
•
The ICMP reset button in the GUI of the Commander.
•
The ICMP reset button in the GUI of the Web Commander.
•
The ICMP hardware reset button located on the front panel of the ICMP (Not recommended, use only when all other reset
possibilities are exhausted!)
How to reset the ICMP?
1. Click on the ICMP
reset button
in the GUI of the
Web Commander
Or,
Click on the ICMP
reset button
in the GUI of the
Commander
Note:
It can be that the Commander or WEB-Commander is not able to send the reset command.
R5906753 DPXK BLP SERIES 20/11/2017
109
Summary of Contents for DP2K-17BLP
Page 4: ......
Page 8: ...Table of contents 4 R5906753 DPXK BLP SERIES 20 11 2017 ...
Page 30: ...3 Installation process 26 R5906753 DPXK BLP SERIES 20 11 2017 ...
Page 40: ...4 Physical installation projector 36 R5906753 DPXK BLP SERIES 20 11 2017 ...
Page 120: ...10 Communicator Touch Panel Image 10 7 Connections 116 R5906753 DPXK BLP SERIES 20 11 2017 ...
Page 152: ...14 Maintenance 148 R5906753 DPXK BLP SERIES 20 11 2017 ...
Page 162: ...16 Color calibration 158 R5906753 DPXK BLP SERIES 20 11 2017 ...
Page 176: ...18 Specifications 172 R5906753 DPXK BLP SERIES 20 11 2017 ...