4-2
CLM W6_CLM HD6 Jan 3, 202
Chapter 4 Function Test & Alignment Procedure
4-3 OSD Reset
1. After final QC step, we have to erase all saved change again and restore the OSD default
setting. The following actions will allow you to erase all end-users' settings and restore the
default setting:
() Please get into OSD menu by press "Menu" button.
(2) Select "Service" by pressing "down" button
(3) To execute "Factory Reset" function.
4-4 Reset Lamp Hour
. After replacing Lamp Module, we have to Reset Lamp
Hour. The following actions will allow you to reset lamp
hour:
() Press the following buttons
- Press "Menu"
- Select "Service" by pressing "down" button on the
remote control
(2) Press "enter"
(3) Select "Lamp hour reset" by pressing "down" button.
Summary of Contents for CLM W6
Page 1: ...CLM W6 HD6 Service Manual ...
Page 10: ...1 CLM W6_CLM HD6 Jan 31 2012 Chapter 1 Introduction 1 2 System block diagram ...
Page 11: ...1 CLM W6_CLM HD6 Jan 31 2012 Chapter 1 Introduction 1 3 Main board connection diagram ...
Page 66: ...Chapter 2 Disassembly Process 2 55 CLM W6_CLM HD6 Jan 31 2012 5 Disassembly is completed ...
Page 74: ...3 5 Image Performance Troubleshooting Chapter 3 Troubleshooting 3 CLM W6_CLM HD6 Jan 31 2012 ...
Page 75: ...3 5 Image Performance Troubleshooting Chapter 3 Troubleshooting 3 CLM W6_CLM HD6 Jan 31 2012 ...
Page 76: ...Chapter 3 Troubleshooting 3 CLM W6_CLM HD6 Jan 31 2012 3 5 Image Performance Troubleshooting ...
Page 78: ...Chapter 3 Troubleshooting 3 11 CLM W6_CLM HD6 Jan 31 2012 3 6 Remote Control Troubleshooting ...
Page 79: ...Chapter 3 Troubleshooting 3 12 CLM W6_CLM HD6 Jan 31 2012 3 7 Network Troubleshooting ...
Page 119: ... CLM W6_CLM HD6 Jan 31 2012 Appendix A Exploded Image 1 2 3 4 4 5 ASSY ENGINE MODULE ...