Random Access Adjustment Mode
6-6
____________________________________________________________________________ R5976381 BARCO CINE6 31012002
menu 1
Select with
é
or
ê
then <ENTER>
<EXIT> to return.
LINE MULTIPLIER
TIME BASE CORRECTION
LUMINANCE DELAY
V SYNC REF :
INDIRECT
CLAMP GATING : OFF
LIMO PRO OPTIONS
FACTORY PRESET
WARNING : ADVANCED
ADJUSTMENT SHOULD BE
PERFORMED ONLY BY QUALIFIED
PERSONNEL
Clamp Gating
Why necessary ?
Clamp Gating is useful when protection signals are present in the vertical interval of the video signal that would otherwise confuse
the LimoPro.
How to change the Clamp Gating ?
1.
Push the cursor key
é
or
ê
to select 'Clamp Gating' (menu 1).
2.
Press ENTER to toggle between ON and OFF.
Default position : OFF.
Vertical Sync Reference
Why necessary ?
DIRECT : This sync processing has the disadvantage that glitches and other disturbances in the video signal sometimes get passed
and hence may cause problems in the image.
INDIRECT : This sync processing throws away any disturbances that are not really sync signals. By source switching a rolling effect
on the image can occur. This sync processing is preferred especially with low quality material.
How to change the vertical sync reference ?
1.
Push the cursor key
é
or
ê
to select 'V Sync Ref.' (menu 1).
2.
Press
ENTER
to toggle between 'direct' and ' indirect'.
Default position : indirect.
Limo Pro Options
How to select the Limo Pro Options ?
1.
Push the cursor key
é
or
ê
to select 'Limo Pro Options' (menu 1).
2.
Press
ENTER
to display the limo pro menu (menu 2).
menu 1
Select with
é
or
ê
then <ENTER>
<EXIT> to return.
LINE MULTIPLIER
TIME BASE CORRECTION
LUMINANCE DELAY
V SYNC REF : INDIRECT
CLAMP GATING :
OFF
LIMO PRO OPTIONS
FACTORY PRESET
WARNING : ADVANCED
ADJUSTMENT SHOULD BE
PERFORMED ONLY BY QUALIFIED
PERSONNEL
Select with
é
or
ê
then <ENTER>
<EXIT> to return.
LINE MULTIPLIER
CORING
LTI
CTI
Warning : advanced adjustment
should be performed only by
qualified personnel !
menu 2
menu 1
Select with
é
or
ê
then <ENTER>
<EXIT> to return.
LINE MULTIPLIER
TIME BASE CORRECTION
LUMINANCE DELAY
V SYNC REF : INDIRECT
CLAMP GATING : OFF
LIMO PRO OPTIONS
FACTORY PRESET
WARNING : ADVANCED
ADJUSTMENT SHOULD BE
PERFORMED ONLY BY QUALIFIED
PERSONNEL