9. Service Mode
Proj 1
Proj 2
Proj 3
Proj 4
in
in
in
in
out
out
out
RS
RS
RS
Terminator
Image 9-7
Principal diagram : linking via RS port
Linking via the Comm port
The constant light output of the projectors can be set to the same value by linking the projectors via the Comm port and using one
or more Comm 800 splitters (See Connections, Linked System).
To slave 1
Master Projector
Comm port
Comm 800 splitter
To slave 2
To slave 3
To next Comm 800 splitter
"To Switcher"
To slave 4
Comm 800 splitter
To slave 5
To slave 6
To slave 7 or to
next Comm 800 splitter
"To Switcher"
Image 9-8
Principal diagram: Linked via Comm port
For more information about the use of the Comm 800 splitter, consult the Comm 800 splitter documentation (R5976819).
Which information is available
serial number
unique serial number of the lamp
type
lamp type
run time
total time the lamp is used in this or other projectors.
remaining run time
time left before the lamp must be replaced Using the lamp longer than the maximum run time may
damage the projector.
number of strikes
Total times the lamp is started up.
Z-AXIS
indication to adjust the Z-AXIS of the lamp (see Re-adjustment of the lamp position in chapter
Installation Guidelines).
R5976562 BARCOSLM G10 PERFORMER 20/10/2004
111
Summary of Contents for BarcoSLM G10 Performer
Page 1: ...BarcoSLM G10 Performer Owners Manual R9010000 R5976562 03 20 10 2004 ...
Page 4: ......
Page 8: ...Table of contents 4 R5976562 BARCOSLM G10 PERFORMER 20 10 2004 ...
Page 14: ...2 Packaging and Dimensions 10 R5976562 BARCOSLM G10 PERFORMER 20 10 2004 ...
Page 34: ...3 Installation Guidelines 30 R5976562 BARCOSLM G10 PERFORMER 20 10 2004 ...
Page 92: ...7 Random Access Adjustment Mode 88 R5976562 BARCOSLM G10 PERFORMER 20 10 2004 ...
Page 124: ...10 Programmable Function Keys 120 R5976562 BARCOSLM G10 PERFORMER 20 10 2004 ...
Page 128: ...A Standard Source set up Files 124 R5976562 BARCOSLM G10 PERFORMER 20 10 2004 ...