2. RS232 Commands
2.31 Clamp Width, Read
Clamp Width does not work with Video, S-video and DVI signals.
Description
Read the actual value of the clamp width.
Command
Command [0]
\x21
Command [1]
\x68
Return Data
Data [0]
Clamp Width Value
Example
Read the actual value of the clamp width of a projector with address
\x01
. Suppose the clamp width equals
\x32
.
Transmit
Start
\xfe
Projector Address
\x01
Command [0]
\x21
Command [1]
\x68
Checksum
\x8a
Stop
\xff
Receive (Acknowledge)
Start
\xfe
Projector Address
\x01
Command [0]
\x00
Command [1]
\x06
Checksum
\x07
Stop
\xff
Receive (Answer)
Start
\xfe
Projector Address
\x01
Command [0]
\x21
Command [1]
\x68
Data [0]
\x32
Checksum
\xbc
Stop
\xff
54