2. RS232 Commands
2.114 Geometry Shift Vertical, Read
Description
Read the vertical shift value.
Availability
From software V2.02 (WARP6 MKII) and V1.01(SIM6 ULTRA HB)
Command
Command [0]
\xfa
Command [1]
\xdb
Data
Data [0]
\x48
Returned Data
Data [0]
Geometry Shift Vertical msb Value
Data [1]
Geometry Shift Vertical lsb Value
Range is from -511 to +511 (2’s complement).
Example
Suppose the value is 100 (=
\x0064
).
Transmit
Start
\xfe
Projector Address
\x01
Command [0]
\xfa
Command [1]
\xdb
Data [0]
\x48
Checksum
\x1e
Stop
\xff
Receive (Acknowledge)
Start
\xfe
Projector Address
\x01
Command [0]
\x00
Command [1]
\x06
Checksum
\x07
Stop
\xff
Receive (Answer)
Start
\xfe
Projector Address
\x01
158
R5976538 BARCOREALITY SIM6 ULTRA SERIES 08/06/2005