2. RS232 Commands
2.233 Size Vertical, Read
Description
Read the actual value of the vertical size.
Command
Command [0]
\x21
Command [1]
\x4a
Return Data
Data [0]
Vertical Size Value msb
Data [1]
Vertical Size Value lsb
Example
Read the actual value of the vertical size of a projector with address
\x01
. Suppose the vertical size equals 0.
Transmit
Start
\xfe
Projector Address
\x01
Command [0]
\x21
Command [1]
\x4a
Checksum
\x6c
Stop
\xff
Receive (Acknowledge)
Start
\xfe
Projector Address
\x01
Command [0]
\x00
Command [1]
\x06
Checksum
\x07
Stop
\xff
Receive (Answer)
Start
\xfe
Projector Address
\x01
Command [0]
\x21
Command [1]
\x4a
Data [0]
\x00
Data [1]
\x00
Checksum
\x6c
Stop
\xff