background image

www.desatech.com

901746-01E

5

INSTALLATION 

  WARNING:  The  Massachu-

setts  State  Board  requires  all 

installations  be  performed  by 

a Licensed Plumber or Gas Fit

-

ter.  Massachusetts  state  code 

requires  all  vent  dampers  be 

welded open or removed.

  CAUTION:  Do  not  remove 

the data plates attached to the 

burner  pan.  The  data  plates 

contain important warranty and 

safety information.

 WARNING: Before installing 

in a solid fuel burning fireplace, 

the  chimney  flue  and  firebox 

must be cleaned of soot, creo

-

sote, ashes and loose paint by 

a  qualified  chimney  cleaner. 

Creosote  will  ignite  if  highly 

heated. A dirty chimney flue may 

create and distribute soot within 

the house. Inspect chimney flue 

for damage.

NOTICE:  Installation,  service, 

and repair of this appliance must 

be performed by a qualified in

-

staller, service agency, company 

or gas supplier experienced with 

this type of gas appliance. Only 

factory authorized components 

listed in these instructions may 

be used in accordance with the 

manufacturer’s instructions and 

all  codes  and  requirements  of 

the  authority  having  jurisdic

-

tion. Any  modifications  to  this 

kit,  or  use  of  unauthorized 

components or accessory items 

will  void  the  manufacturer’s 

warranty,  and  may  result  in  a 

hazardous condition.

FLUE OPENING SPECIFICATIONS

Note: This vented appliance must be installed 

only  in  a  solid-fuel  burning  fireplace  with  a 
working flue and constructed of noncombus

-

tible material.

The charts in Figure 2, page 6, indicate tech

-

nical information regarding the installation of 

your gas log set. Please make sure that all of 
the specifications shown are applicable before 
installation is attempted.
The fireplace must include a working flue and 
venting system with minimum openings 

Summary of Contents for BVDR18

Page 1: ...ctrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire depa...

Page 2: ...you read and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this log set WARNING Improper instal lation adjustment alteration service or maint...

Page 3: ...Cleaning and Maintenance page 11 safety Continued 8 Do not allow fans to blow directly into the fireplace Avoid any drafts that alter burner flame patterns Ceiling fans can create drafts that alter bu...

Page 4: ...A Heating LLC at 1 866 672 6040 for replacement parts before returning to dealer ON OFF Safety Valve Pilot kit and Propane lp conversion An optional valve safety pilot kit with a piezo ignitor is avai...

Page 5: ...erformed by a qualified in staller serviceagency company orgassupplierexperiencedwith this type of gas appliance Only factory authorized components listed in these instructions may be used in accordan...

Page 6: ...y natural gas If your gas supply is not natural gas you must install ON OFF Safety Valve Pilot Kit see Accessories page 19 Call dealer where you bought your log set If the fireplace does not have a ga...

Page 7: ...cation The equipment shutoff valve is for turning on or shutting off gas to appliance Apply pipe joint sealant lightly to male NPT threads This will prevent excess sealant from going into pipe Excess...

Page 8: ...for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Figure 5 2 Pressurize supply piping system by either using compressed air or opening main gas valve...

Page 9: ...ing optional GA9050A 1 kit go to Optional GA9050A 1 On Off Safety Valve Pilot Kit Assembly for installation instructions If using optional GA9150A kit follow instructions included with kit for install...

Page 10: ...gas the burner inlet fitting and pilot orifice must be replaced The propane LP burner inlet fitting is supplied with orifice installed for a 24 log set If you have an 18 or 30 log set you must change...

Page 11: ...s red for a 30 set it is black If you have a 24 log set orifice is already installed inside fitting 3 For an 18 or 30 set use a 10 mm socket or nut driver to remove orifice from pro pane LP burner inl...

Page 12: ...e the individual tongues of flame on the burner Note The burner design includes more ports on the outside of the bar Make sure that all ports are clear and produc ing flame evenly across the burner If...

Page 13: ...he fire department Figure 20 Placement of Top Logs Mossy Maple Logs Shown Installation Continued LIGHTING INSTRUCTIONS 1 STOP Read safety information above 2 Turn the gas shutoff valve clockwise to OF...

Page 14: ...During the 2 3 hour appliance break in pe riod you may detect an odor from appliance as various paints and compounds used in manufacturing of this log set cure This is a normal and temporary situation...

Page 15: ...flame to proper size see Figure 17 page 11 Do not remove adjustment screw see Troubleshooting page 16 BURNER FLAME PATTERN Burner flames will be steady not lifting or floating Flames should go up thro...

Page 16: ...ht bends or kinks in gas supply line 1 Check for proper gas sup ply pressure 2 Free burner orifice and manifold ports of any burrs paint or other blockage 3 Verify proper burner ori fice sizing see Fi...

Page 17: ...urn on gas supply or open equipment shutoff valve 2 Turn control knob to PILOT position 3 Press in control knob while in PILOT position 4 Continue holding down con trol knob Repeat igniting op eration...

Page 18: ...lace control valve 1 Locate and correct all leaks see Checking Gas Con nections page 8 OBSERVED PROBLEM Log set produces a clicking ticking noise just after burner is lit or shut off Log set produces...

Page 19: ...odel and serial numbers of your heater the replacement part number Accessories Purchase these log set accessories from your local dealer If they can not supply these accessories call DESA Heating Prod...

Page 20: ...www desatech com 901746 01E 20 Parts Burner Models BVSR18 BVSR24 BVDR18 BVDR24 AND BVDR30 3 13 6 4 10 7 5 5 9 9 11 12 1 8 2...

Page 21: ...Burner Manifold 1 901208 02 Burner Manifold 1 901209 03 Burner Manifold 1 6 901136 01 Burner Pan 1 901136 02 Burner Pan 1 901137 01 Burner Pan 1 901137 02 Burner Pan 1 901137 03 Burner Pan 1 7 901242...

Page 22: ...ttom Rear Log CS 15 1 901111 02 Bottom Rear Log CS 20 1 901111 03 Bottom Rear Log CS 27 1 2 901711 01 Bottom Front Log VCBQ 13 1 901711 02 Bottom Front Log VCBQ 14 1 3 901710 01 Bottom Front Log VCBQ...

Page 23: ...ttom Rear Log BPP 24 1 3 901101 01 Top Log CHR 13 1 4 901120 01 Top Log VCR 11 1 5 901121 01 Top Log VCR 12 1 6 901103 01 Top Log CHR 13Y 1 7 901115 01 Top Log VR 11 1 8 901713 01 Bottom Front Log BPP...

Page 24: ...ack Log BFL 27 1 2 110299 01 Front Right Log 1 110302 01 Front Right Log 1 124204 01 Front Right Log BFL 30R 1 3 110298 01 Front Left Log 1 110301 01 Front Left Log 1 124203 01 Front Left Log BFL 30L...

Page 25: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Page 26: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Page 27: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Page 28: ...proved by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will provide original factory replacement parts Failure to use origin...