www.desatech.com
901746-01E
9
Installation and Gas Connection
1. Place burner pan assembly in center of
fireplace floor. Make sure inlet end of pan
faces gas supply.
2. Thread gas supply fitting to fireplace gas
supply pipe. Use thread sealant.
3. Install adapter fitting onto burner inlet fit
-
ting using thread sealant on male threads
of burner inlet fitting (see Figure 6). Adjust
to most convenient position.
4. Install gas connector tube to gas supply
fitting. Carefully shape tube to attach to
adapter fitting. Be careful not to cause
kinks in tube.
INSTALLATION
Continued
5. Using thread sealant (resistant to the action
of propane/LP gas) on larger end of fitting,
screw the burner inlet fitting through hole
and into burner manifold. Tighten using
a wrench. If using propane/LP gas, see
Propane/LP Gas Conversion
, page 10.
6. Using burner clamp, screw, and nut pro
-
vided, assemble clamp to pan (“U” style
burners only). This will hold the burner
manifold in place.
7. If using optional GA9050A-1 kit, go to
Optional GA9050A-1 On/Off Safety
Valve/Pilot Kit Assembly
for installation
instructions. If using optional GA9150A
kit, follow instructions included with kit for
installation and operation.
Figure 8 - Installing Burner
Burner Clamp
Nut
Burner
Manifold
Burner Inlet
Fitting
Screw
Burner
Pan
Figure 9 - Installing Burner
Adaptor Fitting
Gas
Connector
Tube
Burner Pan
Assembly (Facing
Front of Fireplace)
OPTIONAL GA9050A-1 ON/
OFF SAFETY VALVE/PILOT kIT
ASSEMBLy
For additional convenience and safety, or
for propane/LP conversion, an optional ON/
OFF safety valve/pilot kit is available. See
Accessories
, page 19.
WARNING: You must use a
ON/OFF safety valve/pilot kit for
propane/LP conversion.
Natural Gas Installation
1. Thread the gas control valve onto the
burner inlet fitting (see Figure 10). Use
thread sealant on the male threads of the
burner inlet fitting. Hold the burner inlet
fitting with a wrench to prevent overtight
-
ening the connection to the burner. Make
sure the control rod is facing the front (see
Figure 10).
Figure 10 - Installing Gas Control Valve
Gas
Control
Valve
Control Rod
Burner Inlet
Fitting
Burner Pan
Assembly