29
Installation instructions
UNILUX-6 265 Three-sided
COLOUR
DIMENSION (cm)
CLEAR OPENING (cm
2
)
Brass or white
13.5 x 13.5
75
(incl. fi tting)
Brass or white
27.0 x 13.5
150
(incl. fi tting)
Convection air fan
(white)
43.0 x 22.0
550
Available BARBAS grids (option) for ventilating the chimney:
• During installation of the appliance, a clearance of 3 mm should be maintained on all
sides of the appliance to allow for expansion of the appliance during operation.
•
If the appliance is to be placed against a bearing wall or against a wall containing
fl ammable material, an air gap of at least 20 mm should fi rst be created
.
Before it a false wall, 100 mm thick, must be built of masonry or aerated concrete
.
•
If the appliance is not placed against a bearing wall or a wall containing fl ammable
material, no false wall is necessary. Layers of insulation of at least 100-mm thickness
will then be suffi cient (class A1, DIN 4102-compliant). See also section 3.3.
•
After four weeks, your appliance will be ready for use
.
3.3.5
Connecting the smoke outlet
The appliance comes with a detachable smoke outlet connection
, with an internal
diameter of 150 mm (Ø14
8 mm external). This connection is intended for steel pipes,
double/single-skinned stainless steel (insulated) fl ues or double/single-skinned fl exible
stainless steel fl ues.
After the appliance has been installed, it can be connected to the fl ue.
In order to be able to disassemble the smoke outlet connection, remove the baffl e
plates fi rst.