Installation instructions
UNILUX-6 265 Three-sided
2.3 ACCESSORIES
The following accessories can be supplied by your dealer:
2.4 HEARTH REQUIREMENTS
The appliance must be placed on a constructional hearth made of solid non-combustible
material, such as concrete or masonry, at least 125 mm thick, including the thickness of
any non-combustible fl oor and/or decorative surface. Combustible material should not
be placed beneath the constructional hearths unless there is an air-space of at least
50 mm between the underside of the hearth and the combustible material, or the
combustible material is at least 250 mm below the top of the hearth.
Figure 1: Minimum dimensions appliance
0LQGHSWK
VHHGLDJUDP[
0LQGHSWK
VHHGLDJUDP
PP
0LQPP
$
%
$ 6XSHULPSRVHGKHDUWK
% &RQVWUXFWLRQDOKHDUWK
Art. no
Accessorie
338223
Convection set General: (for convection air extraction)
302188
• 1x Flexible aluminium pipe Ø125 mm, L= 3 m (max.)
310178
• 2x
Fitting box
135x135 mm
309872
• 2x
Convection exit grid,
white
, 145 x 145 mm
309730
• 2x Collar adaptor Ø125 mm
304040
• 4x Hose clamp Ø125 mm
342138
Classic Frame
309872
Grate ventilation chimney
310178
Fitting box for grate ventilation chimney