27
Installation instructions
UNILUX-6 265 Three-sided
3.3.3
Fitting in an existing chimney
Do not use masking tape on the appliance
when installing and plastering.
Tape can damage the fi nish of the appliance.
•
Remove the existing fi re basket or stoking stones and remove the shut-off fl ap. The
chimney must be intact and must not be damaged during fi tting.
The chimney breast opening must be big enough for a gap of 1 - 3 cm to be left all
round the appliance. Clad the chimney breast opening from the inside with a ceramic
wool fi reblanket or similar (see section 3.3).
•
Extend the existing chimney so that it ends at the appliance’s smoke outlet. To do
this, use a fl exible, double-walled stainless steel chimney, for example.
•
Slide the appliance into the chimney breast opening. Seal the smoke outlet where it
joins the chimney so that no soot can accumulate above the appliance
under any
circumstances
.
See 3.3.4.
•
Level off the appliance so that the cover does not catch on the base.
• Fill any gaps around the appliance with a ceramic insulation wool fi reblanket and
position the frame (where supplied)
.
3.3.4 Fitting in a newly-built chimney
• If required, a convection set can be added when installing the appliance.
* Appliance without convection fan : The use of a convectionset is
strongly recommended.
* Appliance with build-in fan
: The use of a convectionset is possible,
but not mandatory.
• In the case of utilisation of a convection set:
Carefully break out the “break-away openings” at the topside (2x) of the appliance.
Do not use masking tape on the appliance
when installing and plastering.
Tape can damage the fi nish of the appliance.