55
CUATRO-3 75
Installation instructions
4
OPERATION
Cuatro-3 with fan set (option) and convection set (option) built into chimney
Figure 3: Operation
1
Handle
2
Ceramic heat-proof glass
3
Locking slider for operating pin of fl ue gas fl ap
4
Operating pin of fl ue gas fl ap
5
Convection air outlet opening (appliance) (permanent)
6
Natural convection air outlet opening (2x grate) (chimney)
7
Convection air outlet opening (2x grate convection set) (chimney)
8
Wall dimmer (option) with integrated ON-OFF RPM control switch of the Perma Air ®
convection fan (option)
9
Combustion grate
10 Ashtray
11 Inlet opening (2x grate) (chimney) Ventilation air chimney / Convection air / Combustion air
12 Combustion air-supply slider (Combined operation for the primary, secondary and tertiary combustion
air-supply.)
13 Inlet opening (2x) combustion air from living-room. The two openings are only open when no
combustion air intake from underneath the appliance, nor from the outside is possible. This is
already decided during the installation of the appliance. NEVER close off open air intakes.
14 Convection air intake opening (2x). These two openings are only open when no convection air intake
from underneath the appliance, nor from the outside is possible. This is already decided during the
installation of the appliance. NEVER close off open air intakes.
15 Not visible on the drawing: Bend strips on brake plate holder for improving the fl ue draught in bad
draught conditions. See Chapter 4 “Using the appliance for the fi rst time” in the Instructions for use &
maintenance manual.
Summary of Contents for CUATRO-3 75
Page 2: ......
Page 4: ...4 CUATRO 3 75 Installation instructions...
Page 6: ...6 CUATRO 3 75 Installation instructions...
Page 26: ...26 CUATRO 3 75 Installation instructions Opening of 4 convection air outlets...
Page 69: ...69 CUATRO 3 75 Installation instructions...
Page 70: ...70 CUATRO 3 75 Installation instructions...
Page 71: ......