4.5.2
Possibilities for a concentric flue system with a wall outlet
Note: Refer to chapter
for a description of the numbers in the figures.
Install the wall outlet in the correct position as shown in the figure. The centre of the inner
pipe must be positioned above the centre of the outer pipe.
Rigid concentric flue systems
19
1
10/11/12/13
4,28,(100)
14
Y
0.16 m
X
Concentric flue connection on appliance Ø100-Ø150 mm or Ø130-Ø200 mm
Y
(min. - max.)
X
(min. - max.)
Flue gas restriction plate
Concentric connection
on the appliance is
Ø100-Ø150 mm
Concentric connection on
the appliance is Ø130-
Ø200 mm
1.5 - 2.5 m
0 - 0.6 m
-
-
2.5 - 3.5 m
0 - 1.6 m
-
-
Requirements
18
Gas Fire Panorama 90-70
Summary of Contents for 90-70 PF2
Page 1: ...Preparation manual Gas Fire Panorama 90 70 PF2 Serial number Production date...
Page 98: ...Available components for the concentric flue system natural draught 98 Gas Fire Panorama 90 70...
Page 99: ...Available components for the concentric flue system natural draught Gas Fire Panorama 90 70 99...