Available components for the concentric flue
system - natural draught
Caution:
Observe the installation instructions that are supplied with the components of
the concentric flue system.
The appliance with extraction of the flue gasses by natural draught, in combination with
the concentric flue system [Ø100 mm - Ø150 mm] and/or [Ø130 mm - Ø200 mm] (rigid
and/or flexible) for the brand types mentioned below, has been approved in accordance
with the European CE-norm for gas appliances and may therefore be used only with
these systems.
Manufacturer
system
Bellfires
Muelink & Grol system
Poujoulat
DUOGAS system
Ontop
Metaloterm US system
Jeremias/STB (STB = Schoorsteen Techniek
Brummen NL)
H-Twin system
Jeremias
TWIN-GAS system
Modinox
PLA system
The permitted components for these systems are listed in this chapter. The guarantee on
the appliance lapses if it is installed, fully or partially, with other components or a different
flue system. The concentric flue [Ø100 mm - Ø150 mm] and [Ø130 mm - Ø200 mm]
systems can be used with either a newly-built or existing chimney.
Make sure that the wall or roof termination kit that is used for the installation of the
concentric flue system is also listed in the available parts list.
6.1
Appliance part list
Fig No.
Description
1
Gas fire; Concentric flue connection Ø130/Ø200 mm or Ø100/Ø150 mm.
2
-
3
-
4
Restriction plate (The different sizes restriction plates are supplied with every appli-
ance).
5
Chimney, min. Ø150 mm internal, totally gas tight.
6
Chimney or fireproof sleeving. min. Ø160 mm internal.
7
Ø100 mm internal flexible stainless steel gas vent chimney liner AISI 316TI.
8
Ø150 mm internal flexible stainless steel gas vent chimney liner AISI 316TI.
9
-
Available components for the concentric flue system -
natural draught
Gas Fire Panorama 90-70
33